Search:

Type: Posts; User: digo

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    1
    Views
    88

    Exchange 2013?...

    Exchange 2013?
    http://blog.kloud.com.au/2013/11/22/exchange-2013-dns-settings-cause-transport-services-to-crash/
  2. Replies
    299
    Views
    28,254

    Any protocol at layer 2 (data link layer) is...

    Any protocol at layer 2 (data link layer) is inherently non-routable. ARCnet, ATM, Controller Area Network (CAN), Ethernet, Fiber Distributed Data Interface (FDDI), Frame Relay, LocalTalk,...
  3. Replies
    22
    Views
    1,455

    What up Kirk! So you're saying you don't miss...

    What up Kirk! So you're saying you don't miss working with spudders? [emoji1]
    Hope all is well with you man.
  4. Replies
    22
    Views
    1,455

    wow, if their panel looks like this, imagine the...

    wow, if their panel looks like this, imagine the wire sheet on those spyders... definitely wall of shame contender.
  5. Replies
    1
    Views
    162

    Use the file transfer client to copy it from the...

    Use the file transfer client to copy it from the modules folder in the JACE to your 3.7.106 modules
  6. Thread: AX Histories

    by digo
    Replies
    2
    Views
    260

    Start indicates the time it began collecting,...

    Start indicates the time it began collecting, like after a reboot
  7. Replies
    2
    Views
    203

    Strykers are configurable (ASC), Spyders are...

    Strykers are configurable (ASC), Spyders are fully programmable. Either way, you have to proxy your points and create your own graphic template before duplicating them. Both are licensed products. ...
  8. Assuming you dragged...

    Assuming you dragged WeatherService/WeatherReport/Current to a Px page, change the "tempFont" property to 0.0pt, then use a separate bound label to display your own temperature value.
  9. Yes, it's called fox tunneling.

    Yes, it's called fox tunneling.
  10. Thread: Niagara AX?

    by digo
    Replies
    2
    Views
    285

    Paste special gives you the option to retain...

    Paste special gives you the option to retain existing links
  11. Thread: 24vac signal amp

    by digo
    Replies
    5
    Views
    328

    Never

    Never
  12. Thread: 24vac signal amp

    by digo
    Replies
    5
    Views
    328

    Take a picture of it... any chance it's...

    Take a picture of it... any chance it's mislabeled?
    I can see an IDF room having of those CATV signal amplifiers in it. Maybe the 24V transformer is powering the signal amplifier?
  13. Take a look at the property sheet for the...

    Take a look at the property sheet for the LonNetwork, under Monitor you can disable the "Alarm on Failure" property which is a baja:Boolean slot. If you're running 3.6 or newer you shouldn't need a...
  14. Replies
    5
    Views
    417

    ":p" translates to a smiley on the forums :p

    ":p" translates to a smiley on the forums
    :p
  15. Replies
    12
    Views
    403

    Yeah, you're adding a slot, but you're supposed...

    Yeah, you're adding a slot, but you're supposed to edit the facets for the point.
    EDIT: you can get to it from the property sheet
  16. The rule is don't set it any higher than what you...

    The rule is don't set it any higher than what you need. We're talking physical memory here, not disk space. I can't imagine you have that much RAM on this machine. I've never needed to go higher...
  17. niagaraInstallfolder\lib\nre.properties (edit...

    niagaraInstallfolder\lib\nre.properties (edit with notepad while station is stopped)

    java.options=-Xmx256M -XX:MaxPermSize=128M -Dfile.encoding=UTF-8 -Xss256K

    Depending on what version you're...
  18. Replies
    4
    Views
    316

    It appears Honeywell sets these with a...

    It appears Honeywell sets these with a modifyFlag=mfgOnly
    I think these were meant to be modified via either their free LNS plug-in, or the lonhoneywellAXWizards (licensed module) only.
    In AX, the...
  19. Replies
    14
    Views
    1,074

    avoid spaces and dashes in component names, among...

    avoid spaces and dashes in component names, among others

    CTRL + L in workbench, paste this
    module://docUser/doc/aComponentNaming.html
  20. Replies
    4
    Views
    316

    I smell bull****... time to give them a call. ...

    I smell bull****... time to give them a call.

    The flow values you are referring to are stored in the W7751H as SCPTs, (Standard Configuration Properties)
    MinFlow = SCPT 54, offset 8, lenght 2...
  21. Thread: Lon Plug

    by digo
    Replies
    12
    Views
    654

    The ASP043 part number is for the spring clamp...

    The ASP043 part number is for the spring clamp version (SP04302VBNN)
    http://www.onlinecomponents.com/ria-connect-sp04302vbnn.html?p=43130834
  22. Replies
    17
    Views
    1,672

    Sorry guys, I've been MIA (or missing in the...

    Sorry guys, I've been MIA (or missing in the field) for a while.

    Here are the notes I have from the last time I had to set this up.
    Disclaimers: This is not a soup to nuts guide, but contains...
  23. Replies
    299
    Views
    28,254

    If you enjoy reading these long threads, this one...

    If you enjoy reading these long threads, this one is for you http://hvac-talk.com/vbb/showthread.php?t=134016
  24. Replies
    6
    Views
    538

    Might be 15 or more JACEs, he said 15 power...

    Might be 15 or more JACEs, he said 15 power supplies at each rack, which sounds like more than one rack.
    Anything industrial grade sounds ages better than the wall pack.
    Not to mention the cheap...
  25. Replies
    8
    Views
    633

    Home automation system from 1985

    Saw this post and wanted to share.
    http://imgur.com/a/Jb6jW

    Sent from my XT1058 using Tapatalk
  26. %out.value% Search niagara-central for help on...

    %out.value%
    Search niagara-central for help on Bformat, it's not very intuitive unless you dig into the API for a Bcomponent

    Sent from my XT1058 using Tapatalk
  27. Thread: best lap top

    by digo
    Replies
    30
    Views
    1,231

    Pretty sure all 4th gen core-i5 processors can...

    Pretty sure all 4th gen core-i5 processors can handle 64-bit instructions, I think you meant to say you are running a 32-bit OS. Upgrading the OS would allow you to address more than 4GB of RAM,...
  28. Thread: best lap top

    by digo
    Replies
    30
    Views
    1,231

    I did really well with my Dell D820 then. ...

    I did really well with my Dell D820 then. Purchased in early 2007 (about $1500 with docking station), retired in early 2014. During that time, I upgraded from the original 100GB HDD drive to a...
  29. Replies
    8
    Views
    659

    Which network management tool/front end? ...

    Which network management tool/front end?

    Niagara AX - lonhoneywellAXWizards (if your brand is Webs or Vykon)
    Echelon LonMaker - LNS Plugin (free, but requires an LNS database)
    HW Lonspec -...
  30. Replies
    21
    Views
    1,484

    I've been using the HVACR Fluke 116 + infrared...

    I've been using the HVACR Fluke 116 + infrared kit and with the T5-1000 (amp probe) for the last 9 years, and I feel it more than covers my needs for controls. Then again, I'm not responsible for any...
  31. Replies
    2
    Views
    218

    Wireshark...

    Wireshark

    http://layer3.wordpress.com/2009/11/29/tshootingwithwireshark/
    http://wiki.wireshark.org/CaptureFilters
    http://wiki.wireshark.org/Protocols/bacnet...
  32. Replies
    11
    Views
    541

    See this thread:...

    See this thread:
    https://community.niagara-central.com/ord?portal:/discussion/DiscussionThread/9398

    Also, see this one, it explains how the charging cycle/battery test is done:...
  33. Replies
    1
    Views
    186

    Never knew such a thing existed... but it's been...

    Never knew such a thing existed... but it's been obsoleted for some time now. The batteries in the T7790 modules are supposed to last 5 years.
    I have a diagram from Honeywell that shows the Q7790...
  34. Replies
    10
    Views
    757

    It's in that blog post klrogers linked above. You...

    It's in that blog post klrogers linked above. You need an account on niagara-central to access it.
  35. Replies
    7
    Views
    412

    That sounds like one of the vintage SMX...

    That sounds like one of the vintage SMX transceivers from Echelon, model TPM-RS485
    https://www.echelon.com/support/documentation/manuals/transceivers/078-0145-01G.pdf
  36. Thread: DIST File

    by digo
    Replies
    6
    Views
    458

    It depends on whether it's a backup dist, or one...

    It depends on whether it's a backup dist, or one intended to be deployed, like an installation package from a third party vendor.
    Essentially, a dist file is a zip file that contains other files and...
  37. Thread: Calculating BTU

    by digo
    Replies
    6
    Views
    420

    http://hvac-talk.com/vbb/showthread.php?167380-How...

    http://hvac-talk.com/vbb/showthread.php?167380-How-to-Calculate-BTU-s-on-CHW-System
  38. Thread: Niagara Summit

    by digo
    Replies
    22
    Views
    2,233

    I will agree with you on that. Can't say I...

    I will agree with you on that.



    Can't say I agree with you on this. Blackberry's acquisition of QNX is a recent thing. QNX has had a great RTOS for a loooong time.
    Have you been in an Audi...
  39. Replies
    2
    Views
    224

    I don't see why it couldn't be done. You don't...

    I don't see why it couldn't be done. You don't even need Linux to clone one, Clonezilla and Acronis (free with a WD external drive) both support Linux filesystems. Use a USB to SATA dock to make...
  40. Replies
    7
    Views
    551

    The Niagara point folder has the point manager...

    The Niagara point folder has the point manager view. Lots of flexibility there, as you can for example duplicate a folder, select all, and batch edit proxy points, with search an replace...
  41. Replies
    7
    Views
    551

    Don't right-click => New Folder. Instead, click...

    Don't right-click => New Folder.
    Instead, click the "new folder" button in the "Niagara Point Manager" view.
    baja:Folder is not the same as a niagaraDriver:NiagaraPointFolder
  42. Whatever you do, keep separate libraries for your...

    Whatever you do, keep separate libraries for your saved devices and apps.
    I ASSumed that since the SpyderTool 6.1.1 is compatible with 3.6, 3.7, and 3.8, that a device saved in one library would...
  43. Nope, you sure can learn them in as dynamic...

    Nope, you sure can learn them in as dynamic devices. Any future configuration changes, however, would need to be done via ncis on the property sheet, which may not be very user friendly. Those...
  44. Replies
    55
    Views
    4,232

    Introduction to the Lonworks system...

    Introduction to the Lonworks system

    BACnet for field technicians
  45. Replies
    2
    Views
    356

    source...

    source

    I don't think the ACH-550 will handle this application
  46. Thread: New laptop

    by digo
    Replies
    9
    Views
    812

    The new E5440 is way smaller than the old D820,...

    The new E5440 is way smaller than the old D820, yet it still weights quite a bit. At least it's sturdy. Text size in the 14" screen at 1600X900 does look tiny, but at the office I have it docked...
  47. Thread: Valentine's Day

    by digo
    Replies
    10
    Views
    784

    Osiyo you're a gentleman and a scholar. After...

    Osiyo you're a gentleman and a scholar. After reading your post, I took time off during lunch to sneak a surprise visit at my wife's work.
    Hang in there and stay strong, your posts are welcome here...
  48. Thread: New laptop

    by digo
    Replies
    9
    Views
    812

    Congrats on taking the red pill. I just ordered...

    Congrats on taking the red pill. I just ordered a new laptop last week, going with the Dell Latitude 14 5000 series. My D820 lasted about 7 years, well technically it's still running great - I'm...
  49. The controller sure is used often, but can you...

    The controller sure is used often, but can you tell me the default value for that parameter, in both heating and cooling? hint: see page 37...
  50. Derivative is rarely used in HVAC applications,...

    Derivative is rarely used in HVAC applications, only P+I.
    There's a good explanation as to why here:...