  1. Replies
    4
    Views
    281

    Looks cool. You must be single ! LMHO

    Looks cool.

    You must be single ! LMHO
  2. Replies
    26
    Views
    1,160

    Refering back to the OP: 1. I have a slight...

    Refering back to the OP:
    1. I have a slight preference for Pneumatic over DDC when it comes to Damper Actuators. Mainly because of the slight power advantages of the pneumatic ones. The unfortunate...
  3. Replies
    5
    Views
    344

    mcguire07, I did a web search for a "MAP 1810"...

    mcguire07,
    I did a web search for a "MAP 1810" and everything comes back with references to a ZFR1810 wireless coordinator.

    What exactly is a "MAP-1810" and how is it supposed to work?

    If you...
  4. Replies
    26
    Views
    1,160

    basparky, Remember, the "Fail Safe" function for...

    basparky,
    Remember, the "Fail Safe" function for both DDC and Pneumatic is based on a "Failure" condition. Pneumatically it is loss of Air Pressure and Electrically it is loss of power.

    In both...
  5. Replies
    4
    Views
    368

    Sparky420, Are you using either Win7 or a 64 bit...

    Sparky420,
    Are you using either Win7 or a 64 bit Machine ? My project builder locks up on my Win7 32bit machine after about 6 mouse clicks. Works perfect on the old WinXP-Pro machine.

    Dunno if...
  6. Replies
    12
    Views
    736

    incontrol, I believe that you need to create...

    incontrol,

    I believe that you need to create Hx graphics taylored for the iPad/iPhone users. Px graphics are a mix of html and Java. Hx graphics are only html. Since the Vowels (my name for the...
  7. Replies
    3
    Views
    275

    alliedtech12887, First guess is that you are...

    alliedtech12887,
    First guess is that you are running PCT-6.0.0.9200 or earlier and the PCG is loaded/programmed with 10.0.0.2400(?)

    That error is normally due to the device having a newer rev of...
  8. Replies
    6
    Views
    361

    Integrator, So is it freeware ? (never mind,...

    Integrator,
    So is it freeware ? (never mind, didn't read all the way to the bottom) . I know what the GSA price is for M-Tools.

    Just a side comment here, I don't know if I see a real benefit to...
  9. Replies
    6
    Views
    361

    integrator, Look for the *.prn and *.ddl files....

    integrator,
    Look for the *.prn and *.ddl files. Both are strictly text based files and can be opened with notepad, wordpad and MS-Word.

    If all you have are the *.cfg and *.acs files then you need...
  10. My thought exactly. Without a "Network...

    My thought exactly. Without a "Network Manager/Supervisor" the only way I have ever had it work reliably is to sync the Fans/Drives. As long as your wire distance is fairly short (< 150') it should...
  11. Thread: JCI CCT FAQ

    by Cagey57
    Replies
    8
    Views
    536

    NSSF, Think of State Tables as GX-9100 PLC's and...

    NSSF,
    Think of State Tables as GX-9100 PLC's and the others stuff as GX-9100 PM's. The hard part is learning how to actually utilize the basic modules to perform your desired functions.

    FWIW, I...
  12. Thread: JCI CCT FAQ

    by Cagey57
    Replies
    8
    Views
    536

    NSSF, Have you tried using the "System...

    NSSF,
    Have you tried using the "System Selection" method ? That might speed up the learning process by looking at some standard compliations of Logic and State Table functionality.
  13. Replies
    29
    Views
    1,736

    Ditto ! Joey, just wait till you get Old and...

    Ditto ! Joey, just wait till you get Old and Tired. The floor get really hard after the big 5 Ohhhh.

    Really !

    I have 2 or 3 of the Lifetime Folding tables and they are all labeled "Not Your's...
  14. Unless you have a very unique system (or I have...

    Unless you have a very unique system (or I have lost my mind) ALL the points in a Point Group exist (in the "Points") on some device.

    I must be missing something here, sorry.
  15. Gaseous Anomaly, Brief "how To' assuming you...

    Gaseous Anomaly,

    Brief "how To' assuming you have sufficient access to the system:
    1. Expand Station/Administration/Graphics Templates, open Graphics templates folder.
    2. Copy...
  16. Maybe you could just simply map the points from...

    Maybe you could just simply map the points from the actual "Points List" directly to a PX file. Saves a step the way I see it. JMO
  17. Thread: hvacpro

    by Cagey57
    Replies
    14
    Views
    1,352

    I would suggest using HAVC-Pro 8.08 with the...

    I would suggest using HAVC-Pro 8.08 with the "B"-Patch.

    Another option is the B & B Electronics 485SD9TB Converter if you have a 9pin Serial port. I have always used it with out an external power...
  18. Replies
    7
    Views
    627

    Tigger, We have a project in Cherry Creek that...

    Tigger,
    We have a project in Cherry Creek that just got one retrofitted (replaced an old 19DX ?) a few month ago. PM me and maybe we can get you down there to have a look.

    In the past few years...
  19. Replies
    21
    Views
    1,644

    TheControlsFreak has it almost dead on. Been...

    TheControlsFreak has it almost dead on.

    Been doing controls specifically for almost 20 years. My DMM is a Fluke 115 (with the real leads not those skinny peices of junk), had a 116 but it is...
  20. Replies
    3
    Views
    231

    mechmike2, Default IP address for NET1 (right...

    mechmike2,
    Default IP address for NET1 (right hand jack) should be 192.168.1.149

    Be careful connecting to an FX with MH WB version. The new FX-60 is likely licensed at Ax 3.7 or Ax 3.8 and there...
  21. Thread: N2 Wiring?

    by Cagey57
    Replies
    6
    Views
    350

    fisha, s2sam is one of our resident experts on...

    fisha,
    s2sam is one of our resident experts on RS485 ! (as always sam, thanks for your knowledge)

    Go here http://cgproducts.johnsoncontrols.com/default.aspx?main.aspx&2 and look for "Metasys...
  22. Replies
    13
    Views
    612

    Oops, my bad you may have to write at priority 8...

    Oops, my bad you may have to write at priority 8 since it's an AI. You'll figure it out.
  23. Replies
    13
    Views
    612

    Add a Numeric Writable, assign it to AI-2, name...

    Add a Numeric Writable, assign it to AI-2, name it "WCADJ1". Then set the Fallback to "0". Then copy/paste it into the points sheet for every VMA you want to have that feature on. If your not sure...
  24. Replies
    11
    Views
    588

    techservices, To answer your question, "I would...

    techservices,
    To answer your question, "I would be really suprised if it did "! (short answer No!)

    Suggest you use 18/3 Shielded cable and make the connection for the UNT on the same terminals as...
  25. Replies
    8
    Views
    879

    K2000, As mechdorn said it is very regional. We...

    K2000,
    As mechdorn said it is very regional. We do have a "Budget Estimate" based on a per Box amount. We typically run our own 24VAC power wiring ourselves but that is also due to prevailing...
  26. Replies
    22
    Views
    1,239

    54885488, I tried numerous time to get it to...

    54885488,
    I tried numerous time to get it to work. As far as I know it (HVAC-Pro) is so timing specific that it wont work over ethernet.

    PM s2sam or steves4 with your question. They are pretty...
  27. Replies
    22
    Views
    1,239

    54885488, We have used the Moxa Nport devices on...

    54885488,
    We have used the Moxa Nport devices on both Companion (nearly Identical to a Facilitator) and NCM's (OT Mode) with good success. The only isues are getting the serial side (RS-232)...
  28. Replies
    10
    Views
    751

    T87F, I suggest you load FX-WB 1.2, 2.0 so you...

    T87F,
    I suggest you load FX-WB 1.2, 2.0 so you don't have problems with that FX-40.
    You should be able to download it from the FX-Pro users forum (Connected Community) if you have access.

    I...
  29. Replies
    1
    Views
    331

    leakcheck, You may already know this but there...

    leakcheck,
    You may already know this but there were/are issues with an TEC210x series T-stat if it is the last device on the bus/trunk.

    If I remember right you need a 220 Ohm EOL resistor and a...
  30. go here...

    go here http://cgproducts.johnsoncontrols.com/default.aspx?main.aspx&2

    Search for lit-6363081, see page 30 for a picture.

    That should clear up your problem.
  31. Check the AI Input jumpers on the lower left...

    Check the AI Input jumpers on the lower left corner of the device. They can be set for 0-10VDC, 0-2VDC or Temp (bottom Sw down, top Sw up if I remember right). It's printed on the label above the...
  32. Dumb question here, did you check the Input DIP...

    Dumb question here, did you check the Input DIP switches ?

    If the siwitches are correct, simply re-assign your input from AI-3 to AI-6 and see what happens.

    Ohm the sensors, 1000ohms at 70 Deg...
  33. Replies
    3
    Views
    804

    Basparky, see attached from HVAC-Pro Help.

    Basparky,
    see attached from HVAC-Pro Help.
  34. Replies
    23
    Views
    1,707

    54885488, Can you post a pic of the...

    54885488,
    Can you post a pic of the "Facilitator" you have ?
    Your comment about (FA?)-UNT111-1 implies that you have HAVC-Pro, what version ?
    Maybe start a thread in the Pro Controls Forum and we...
  35. Replies
    23
    Views
    1,707

    The configuration 54885488 has is with the FX-60...

    The configuration 54885488 has is with the FX-60 or facilitator located in the center of the Bus. Each side/segment can have 5000' developed length and 50 devices per side/segment.

    Pretty sure...
  36. Replies
    8
    Views
    606

    alliedtech12887, Put an email in your profile....

    alliedtech12887,

    Put an email in your profile. Good things could come your way !

    HVAC-Pro "8.08B" is a patch and not a full distribution release.
  37. Replies
    8
    Views
    606

    2 things to look for: 1. Are the VMA's at...

    2 things to look for:
    1. Are the VMA's at HVAC-Pro version 8.08b ? If not they really should be upgraded to 8.08b !
    2. Check the COV values in the VMA's. I usually change them to 1.0 for temps and...
  38. LOL, ROFLMHO !!! You guys are awesome ! I...

    LOL, ROFLMHO !!!

    You guys are awesome !

    I could write a seriously Osiyo-onic post (that's a compliment BTW) about this topic.

    We have one customer who uses a specific Mechanial Engineer....
  39. Do you mean "Specifying Engineers" (Typically...

    Do you mean "Specifying Engineers" (Typically Mechanical Engineers) ? If so my advice would be to (a rant here !) :

    Study Controls instead of having the concept that "If I can Think it You (the...
  40. Replies
    1
    Views
    384

    You will need to order p/n AP-TBK1002-0 for 2...

    You will need to order p/n AP-TBK1002-0 for 2 pole terminals and AP-TBK1003-0 for 3 pole terminals.

    They are very proud of those things so don't be too surprised at the price.
  41. Try "123" (a guess), the pasword is 3 digits and...

    Try "123" (a guess), the pasword is 3 digits and the ZTU is pretty much Locked out without the correct password. Your other option is to get the Software/Interface and connect directly to the ASC...
  42. Thread: JCI Wireless

    by Cagey57
    Replies
    4
    Views
    611

    Mount your RTU Controller (FX-PCG) inside the...

    Mount your RTU Controller (FX-PCG) inside the building, it's not rated for low temp anyway. Connect the "Flag" to the PCG and you're off and running. Just make sure your PCG/"Flag" is either setup...
  43. orion242, I'll "pass" on lastpass. Sombody...

    orion242,
    I'll "pass" on lastpass. Sombody hacked the personal email account so now I only save 1 password on the PC and thats only because the host makes me change it every 14 days, what a pain.
    ...
  44. Replies
    4
    Views
    494

    Not positive but you should be able to add the...

    Not positive but you should be able to add the "Control System" and prego, it's in there (LCT) ! But I could be wrong.

    "Wrong" seems to be my normal state lately, Ha ha ! No, Really !
  45. Nice article. Now if we (in the controls...

    Nice article.
    Now if we (in the controls industry) can convince Network Management that VPN's and VLAN's are the first line of defense (and my preference) and the Operating personnel that "Strong...
  46. Thread: What?

    by Cagey57
    Replies
    6
    Views
    664

    Heck yes ! And when you're cold turn it up to 85...

    Heck yes ! And when you're cold turn it up to 85 and you'll get warn faster, Right ?

    Really ? :gah:

    "Never underestimate the power of human Stupidity" Woodrow Willson Smith/Lazarus Long.
  47. Replies
    6
    Views
    608

    As far as I know there are multiple "Station...

    As far as I know there are multiple "Station Saves" in the JACE that are date specific. If you know where to look you may find several dated config_backup_date_time.bog files.

    Each "Backup" file...
  48. Replies
    2
    Views
    744

    Look into why OCC-C (2)and OCCSCHED (3) have...

    Look into why OCC-C (2)and OCCSCHED (3) have different values.

    The other thing is to find out if Cooling PRAC is "True". If so turn it off (False) and set your Cooling Prop band to 10 and your...
  49. Replies
    7
    Views
    1,209

    rgcowie4D, All you need is CCT to...

    rgcowie4D,
    All you need is CCT to setup/check-out your wireless. We have had an unusually high failure rate with the Wireless Coordinators (more than 10%) recently and your description could...
  50. Replies
    29
    Views
    3,794

    RD9000, A couple FYI's, first no more pricing in...

    RD9000,
    A couple FYI's, first no more pricing in posts (site Rules)., second with the 14 (?) devices you have and FX-20 (if they are still available) is capable of supporting them.

    In the market...