  1. Replies
    4
    Views
    360

    I've seen a few soot up because the control valve...

    I've seen a few soot up because the control valve did not shut off all the way once the tstat was satisfied. It'd be like a big candle underneath the burner. Some controls do shut off eventually...
  2. Replies
    17
    Views
    1,550

    No, upflow. Wierd I know, but it fixed it in...

    No, upflow. Wierd I know, but it fixed it in this case.
  3. Replies
    17
    Views
    1,550

    Tstat isn't wired wrong so strip heat runs at the...

    Tstat isn't wired wrong so strip heat runs at the same time as the heat pump, right? I just fixed one that had been there for ten years with that problem. Customer had been told the HP switch was a...
  4. Replies
    8
    Views
    834

    American Copper and Brass sells "Anvil" ...

    American Copper and Brass sells "Anvil" brand www.acandb.com

    Leran sells "Ward" brand www.e-leran.com

    We've used both brands for years...
  5. All that I've installed have a manual "on, off,...

    All that I've installed have a manual "on, off, remote" button on the remote box, you should be able to operate the fireplace with or without a remote.
  6. Replies
    73
    Views
    10,289

    The number one thing that checking static...

    The number one thing that checking static pressure has helped me with is fixing condensation problems. Almost all the horizontal attic units that I've seen with a pan full of water under them have...
  7. Thread: Hot in Texas

    by gasser65
    Replies
    26
    Views
    1,548

    Elbows are ok - they are insulated aren't they. ...

    Elbows are ok - they are insulated aren't they. Ductboard triangles are not very good even if they aren't leaking. I'd get a reputable company to re- work your duct system and seal it up correctly.
  8. Two 16x25 equals about 1100 cfm. A five ton is...

    Two 16x25 equals about 1100 cfm. A five ton is capable of producing about 2000 cfm. Maybe it is pulling in more dirt because it is sucking so hard through returns that are too small.
  9. Replies
    6
    Views
    1,015

    Check this out: ...

    Check this out: ...
  10. Replies
    6
    Views
    995

    Fieldpiece SC56

    Does this meter have a magnet for attaching it to a unit, breaker box, etc.?
  11. Thread: low charge

    by gasser65
    Replies
    6
    Views
    3,033

    No cooling and excess condensate from ice buildup.

    No cooling and excess condensate from ice buildup.
  12. Replies
    5
    Views
    979

    If you use propane with a 1# tank, check this out...

    If you use propane with a 1# tank, check this out it's refillable


    http://www.mantank.com/newsletters/1lb.html
  13. Replies
    1
    Views
    991

    Empire Vent material

    Does anyone have a reliable vendor for "Direct Vent" venting materials for Empire brand DV Fireplaces? Both my vendors have stopped carrying Empire and they can't even tell me who to call to get...
  14. I'd call your installer back or maybe another...

    I'd call your installer back or maybe another service tech familiar with the type of unit you have to see what is going on then.
  15. Does the outside unit run when you turn the...

    Does the outside unit run when you turn the thermostat to "heat on". If not, the emergency / gas heat is providing all the heat - which will cause you to use more gas.
  16. Replies
    32
    Views
    7,287

    You should be due a credit on your account if the...

    You should be due a credit on your account if the tank is owned by your gas provider. I usually will credit our customers a minimum of 25 gallons worth if one of our company owned tanks develops a...
  17. Replies
    32
    Views
    7,287

    I own a propane company. Your provider is not...

    I own a propane company. Your provider is not following the proper protocol in this situation. If one of our customers calls and says they smell gas, we get there as quick as we can after advising...
  18. Replies
    11
    Views
    731

    We've sold propane heaters for many years - they...

    We've sold propane heaters for many years - they do not make a propane space heater w/24V controls as far as I know. Why not just use the space heater as the heat source when you need it and turn on...
  19. Replies
    9
    Views
    812

    I am a propane supplier, here is what we see that...

    I am a propane supplier, here is what we see that causes excessive gas usage most often: 1)Leaking valves or gauge on the propane tank. 2)Regulators venting gas. 3)Leaking underground gas...
  20. Replies
    47
    Views
    4,325

    I know the rules, what part of my post do you...

    I know the rules, what part of my post do you consider DIY?
  21. Replies
    47
    Views
    4,325

    If the gas flex connector is one of the old gray...

    If the gas flex connector is one of the old gray coated brass ones, you need to replace it. We see those old ones crack and leak quite often. Also, the flex connector isn't supposed to be inside...
  22. Replies
    16
    Views
    1,289

    You don't say what Carrier units we are comparing...

    You don't say what Carrier units we are comparing to the Payne units, so I can't say for sure, but... most Carrier outside units have more protection covering the outside coil, i.e. "louvered cases"....
  23. Replies
    9
    Views
    1,411

    You don't have a lot of your registers closed in...

    You don't have a lot of your registers closed in rooms you don't use or something like that do you?
  24. Replies
    12
    Views
    1,490

    I've seen mercury in the old mercury bulb tstats...

    I've seen mercury in the old mercury bulb tstats bounce back and forth on startup and freak out the time delay in the condenser, but never on three units in the same house and usually the condenser...
  25. Replies
    19
    Views
    3,917

    That's a lot of ice! That propane bottle in the...

    That's a lot of ice! That propane bottle in the pictures really shouldn't be in an enclosed area - if the relief valve vents it could make a real big bang.