  1. I've got a few of those doing same thing at a...

    I've got a few of those doing same thing at a facility I work on. What the technical book says is either bearings or gear motor relay being weak. For my situation it ended up being the relay

    ...
  2. Replies
    10
    Views
    939

    Low voltage or line voltage fuse? Sent from...

    Low voltage or line voltage fuse?


    Sent from my iPhone using Tapatalk
  3. Replies
    40
    Views
    1,945

    This is common and does happen when it's only a...

    This is common and does happen when it's only a one way motor. Swap the power wires from the motor cap and make it go correct direction. No mystery about it.


    Sent from my iPhone using Tapatalk
  4. Replies
    14
    Views
    1,275

    I carry the 902. But have grown to like my 179...

    I carry the 902. But have grown to like my 179 more. I have a amp probe attachment for my 179 but i trust fluke.
  5. Replies
    2
    Views
    274

    Get your posts up and apply for pro membership...

    Get your posts up and apply for pro membership then we can help ya.
  6. Replies
    26
    Views
    2,146

    No way in hades can anyone give an accurate...

    No way in hades can anyone give an accurate pressure reading on a partially frozen coil! And for that matter. If you chose to just recharge the system make him use a scale and watch what he puts in....
  7. I would say over charged. Or fan motor cutting...

    I would say over charged. Or fan motor cutting out(i. E. bearings)
  8. Can't help ya out. Need to get your posts up then...

    Can't help ya out. Need to get your posts up then apply for a pro membership. Then maybe the troubleshooting can begin
  9. Second electric heat may be running. But if...

    Second electric heat may be running. But if there's a 20 degree TD idk. Unless readings are fudged......
  10. The secondary drain issue is not an issue for...

    The secondary drain issue is not an issue for this matter. If you want them to add it in just for your peace of mind then by all means ask them too. But in no way is that an install error. Labor is...
  11. Replies
    13
    Views
    1,105

    Lets get this strait.....checked amps on non...

    Lets get this strait.....checked amps on non running equipment.....replacement of 3 capacitors for two components.....and freon is good but the equipment isn't running so there's no real way to check...
  12. Replies
    14
    Views
    1,248

    I use the fluke 1587(i believe that's the correct...

    I use the fluke 1587(i believe that's the correct model number) it's a meggar/meter combo. Love it. Found plenty of nuisance problems, and i use it when my reg meter takes a plunge.
  13. Replies
    8
    Views
    1,505

    I use a d-tek on all freons. It doesnt like...

    I use a d-tek on all freons. It doesnt like finding 404 or 410, sometimes no problem, sometimes big problem. I picked up a new JB prowler that has a vibrating function that helps esp when it's in a...
  14. Replies
    5
    Views
    687

    I won't do a manual J until if got the job. The...

    I won't do a manual J until if got the job. The contractor was aware of the windows an insulation if he suggested a lower btu furnace. Manual j takes time. And if im seeing alot of customers just...
  15. Replies
    20
    Views
    1,602

    I use bow bender for everything i can. Regular...

    I use bow bender for everything i can. Regular and reverse bends. Cuts down on the amount of welds and it's pretty compact
  16. Biggest thing is make sure the compressor has a...

    Biggest thing is make sure the compressor has a sound blanket.
  17. Thread: Work boots!

    by Crazecodyk
    Replies
    122
    Views
    15,438

    I've always work wolverines. Was going through...

    I've always work wolverines. Was going through two pair a yr. last round i bought some redwings hoping that they'd last longer esp since they were 189.00. They are comfy but sadly no more life than 6...
  18. Replies
    4
    Views
    400

    Congrats and welcome. One question though. When...

    Congrats and welcome. One question though. When you say branch out on tour own do you mean with in your family company as a partner or clean slate, new name new everything? If you like having family...
  19. Replies
    8
    Views
    1,039

    Went back to check, low mv signal, told customer...

    Went back to check, low mv signal, told customer price and they said nopie, which i was glad to hear. They ended up covering the hole and mounting heater on the wall in front of it
  20. Replies
    8
    Views
    1,039

    300. Cool. That's what i was looking for.

    300. Cool. That's what i was looking for.
  21. Replies
    8
    Views
    1,039

    Williams Wall Heater questions

    i have a williams wall furnace that a customer is wanting to get going again, hasn't ran in probably over ten years.
    the model # 35GV-5 s# A47820
    Does not look like it has a blower assembly,...
  22. Simple fact: HO took charge to change his t-stat....

    Simple fact: HO took charge to change his t-stat. Unit was running beforehand. There is no way that's a warranty call. That's a service charge through and through. No gray area here. How it should be...
  23. Replies
    3,304
    Views
    113,982

    I don't need to, but it is a right given to me by...

    I don't need to, but it is a right given to me by the 2nd amendment, it is also my choice to own guns for various reasons. Hunting,personal defense, recreational events, and the most important reason...
  24. Replies
    8
    Views
    688

    Check your supply voltage to your primary side of...

    Check your supply voltage to your primary side of transformer, make sure correct voltage is being used.
    Then i would check on output side of transformer,
    If all good there check for loose...
  25. I strongly say yes to drug testing for a...

    I strongly say yes to drug testing for a privileged commodity. I have to get drug tested so i can make my money and i far too often seen where my money goes and who it "helps" more people abuse the...