  1. I'm in Minnesota (zone 5) ditch the 16 seer. Not...

    I'm in Minnesota (zone 5) ditch the 16 seer. Not anymore comfortable than 13 seer and your cooling season is too short and the payback is probably 20-30 years or more. Sounds like your evaporator...
  2. Replies
    10
    Views
    332

    oh and by the way if you bought the furnace on...

    oh and by the way if you bought the furnace on the internet then there's usually no warranty as most manufacturers have that posted on their websites
  3. Replies
    11
    Views
    452

    strip heaters running

    strip heaters running
  4. Replies
    4
    Views
    361

    yea make pictures larger

    yea make pictures larger
  5. Replies
    9
    Views
    441

    although the higher efficiency would be a good...

    although the higher efficiency would be a good option for your area, you'll realize greater savings by sealing and insulating the house. Who said you're old furnace is undersized (the service tech?)...
  6. Replies
    15
    Views
    718

    hello It's a ductless split condenser. yeah it...

    hello It's a ductless split condenser. yeah it could warm the room up, but you literately could sleep right next to it and get a good nights sleep as it's so quiet
  7. Replies
    9
    Views
    389

    woooh don't necessarily jump to conclusions. Yes...

    woooh
    don't necessarily jump to conclusions. Yes it could be an unscrupulous contractor, but then again could have just been a piece of insulation that came loose from the air handler/furnace. Your...
  8. Replies
    8
    Views
    259

    yea forgot about those

    yea forgot about those
  9. Thread: Hilmor

    by superfittertech
    Replies
    26
    Views
    1,184

    can't swage hard copper as it will crack only use...

    can't swage hard copper as it will crack only use on soft copper
  10. Replies
    8
    Views
    259

    that's not the big boy. The big boy is the...

    that's not the big boy. The big boy is the Milwaukee spline. Will make holes up to 2" even in the hardest concrete
  11. Replies
    74
    Views
    1,900

    subcooling only matters if a txv is installed and...

    subcooling only matters if a txv is installed and there is no receiver. (usually don't see it in refrigeration)
    although shortly some nay Sayers who'll tell me that's not right
  12. as far as WiFi is concerned All Mitsubishi...

    as far as WiFi is concerned All Mitsubishi "Hyperheat" unit systems are RedLink™ enabled for MHK1 Wireless Remote Controller kit. If they're RedLink (Honeywell wireless) usually you can add a gateway...
  13. Replies
    4
    Views
    227

    any modcon boiler will save money over the oil...

    any modcon boiler will save money over the oil boiler. No need to change out piping. Pipe primary/secondary, install spirovent and a diaphragm tank. & be sure to install outdoor sensor for reset. The...
  14. Replies
    23
    Views
    519

    without seeing it, I'd say lazy contractor. Call...

    without seeing it, I'd say lazy contractor. Call someone else. 2nd opinion needed
  15. Replies
    43
    Views
    1,519

    only on 3 ton and above and on high end units

    only on 3 ton and above and on high end units
  16. Replies
    13
    Views
    658

    Goodman has all aluminum coils and I think...

    Goodman has all aluminum coils and I think Nordyne has all aluminum microchannel coils
  17. Replies
    33
    Views
    1,042

    try washing the indoor coils with a solution of...

    try washing the indoor coils with a solution of water and automatic dish washing detergent. Sometimes the manufacturing process leaves residual oil on the aluminum fins and since it's slick fan blows...
  18. Replies
    15
    Views
    727

    if you can diagnose and find a place open on a...

    if you can diagnose and find a place open on a Sunday then have at it. That's why it's called EMERGENCY service. Tech is paid overtime or double-time + gas and insurance. It all adds up
  19. what if you used a 3t condensing unit with a 5t...

    what if you used a 3t condensing unit with a 5t coil + furnace had ECM and thermostat that also has a dehumidification mode similar to vision pro IAQ. When latent load was high run cfm's around 900,...
  20. Replies
    17
    Views
    592

    could be OK. This is more like I was talking...

    could be OK. This is more like I was talking about.

    http://www.supplyhouse.com/Fantech-SE704N-SE-Series-Energy-Recovery-Ventilator-4-Side-Ports-up-to-1200-Sq-Ft
  21. Replies
    17
    Views
    592

    many options. you can run off a timer,...

    many options. you can run off a timer, dehumidistat, thermostat or just a plain old wall switch. The best ones made by Fantech & Honeywell use small backward inclined fractional HP ECM motors. Use...
  22. Replies
    7
    Views
    301

    glad to help

    glad to help
  23. Replies
    17
    Views
    592

    Install a stand alone ERV or HRV

    Install a stand alone ERV or HRV
  24. Replies
    17
    Views
    592

    best solution get rid of the cats and litter box

    best solution get rid of the cats and litter box
  25. Replies
    17
    Views
    451

    up blast has a cover over the motor only and the...

    up blast has a cover over the motor only and the outside of the fan wheel is open and has a larger opening kind of like a bowl that discharges the exhausted air straight up and down blast has a...