Search:

Type: Posts; User: JCT

Page 1 of 4 1 2 3 4

Search: Search took 0.00 seconds.

  1. Thread: W/W geo

    by JCT
    Replies
    13
    Views
    1,774

    So why are there going to be problems in the next...

    So why are there going to be problems in the next 2 or 3 years and what kind of nightmares will there be? That's a simple system to work on! And happy customers don't call other contractors to work...
  2. Replies
    4
    Views
    581

    $9000

    $9000
  3. Replies
    4
    Views
    581

    SOLD Nitec layout table for sale

    For any contractor doing handsheet metal layout this is what you need to speed things up. 3 year old machine in new condition
    www.nitecinc.com
  4. Thread: W/W geo

    by JCT
    Replies
    13
    Views
    1,774

    Aquatherm pipe it's all fusion welded

    Aquatherm pipe it's all fusion welded
  5. Thread: W/W geo

    by JCT
    Replies
    13
    Views
    1,774

    W/W geo

    468291468301468311468321

    No much just a little work from this week. 6 ton geo with radiant floor and hydronic air handler with zoned duct system. Bosch combo boiler for dual fuel heating rate and...
  6. Replies
    6
    Views
    1,324

    The equipment is not the problem it's the way...

    The equipment is not the problem it's the way everything is setup. I have done many houses with about the same setup, 8 to 10 ton ww with multiple air handlers and radiant. I have installed lots of...
  7. Thread: Hospital upgrade

    by JCT
    Replies
    14
    Views
    2,532

    All insulated piping is victaulic and steel pipe,...

    All insulated piping is victaulic and steel pipe, only used aquatherm on domestic water .Insulation is fiberglass with PVC jacketing over top, I put jacket ting on a lot of my stuff it lasts longer...
  8. Thread: Hospital upgrade

    by JCT
    Replies
    14
    Views
    2,532

    To fill you all in a little better . We took out...

    To fill you all in a little better . We took out two old kewane boilers and the 2 300 gal DHW tanks that were hooked to them, also the constant speed pumps, old air controls and chiller that was a...
  9. Thread: Hospital upgrade

    by JCT
    Replies
    14
    Views
    2,532

    ok sorry i screwed up here and it end up being...

    ok sorry i screwed up here and it end up being two posts. tried to get before and after on one
  10. Thread: Hospital upgrade

    by JCT
    Replies
    14
    Views
    2,532

    Hospital upgrade

    441921441931441941441951441961441971441981441991This is what i have been working on. These are before pics of boilers, air controls, pumps and air handlers.

    I installed 6 new 599 boilers, 4...
  11. Thread: Hospital upgrade

    by JCT
    Replies
    1
    Views
    547

    Hospital upgrade

    This is what i have been working on. These are before pics of boilers, air controls, pumps and air handlers.


    441821441831441841441851441861441871441881441891441901
  12. Replies
    21
    Views
    3,840

    Ya that source side piping is bad!! Going to want...

    Ya that source side piping is bad!! Going to want to check flows on each unit not piped right in my opinion
  13. Thread: 24 TON GEO

    by JCT
    Replies
    9
    Views
    1,281

    24 - 200ft vertical loops

    24 - 200ft vertical loops
  14. Thread: 24 TON GEO

    by JCT
    Replies
    9
    Views
    1,281

    Ya there's a few bucks there,also did exhaust...

    Ya there's a few bucks there,also did exhaust system, airlines and plumbed pressure washer lines in wash bay. Building used for storage but mainly working on equipment.
  15. Thread: 24 TON GEO

    by JCT
    Replies
    9
    Views
    1,281

    I normally don't put any backup heat in but we...

    I normally don't put any backup heat in but we added a 4500 cfm exhaust fan and intake in wash bay and 2500 cfm exhaust for welding hood after the geo was done so I put at electric boiler in for...
  16. Thread: 24 TON GEO

    by JCT
    Replies
    9
    Views
    1,281

    24 TON GEO

    361221361231361241361251361261361271361281

    ANOTHER FARM SHOP 80X210 WITH 25X25 OFFICE
    2 12 TON W/W GEO UNITS, RADIANT FLOOR, 15 AIR HANDLER AND 28" 120' DUCT SOX FOR SHOP AC, 2 TON HYDRONIC...
  17. Replies
    8
    Views
    1,691

    Geosystems- hydro heat and econar has been...

    Geosystems- hydro heat and econar has been purchased by enertech who owns hydron module mega-tek is Hydro Heat and i don't think enertech is making them any more thank god i used to put them in...
  18. Thread: 18 ton geo

    by JCT
    Replies
    4
    Views
    1,463

    I do everything on my jobs piping ,insulation,...

    I do everything on my jobs piping ,insulation, build duct, control wiring.
  19. Thread: 18 ton geo

    by JCT
    Replies
    4
    Views
    1,463

    18 ton geo

    319511319521319531319541

    18 ton w/w geo system in farm shop. radiant floor, and 15 ton hydronic air handler with 28" duct sox to be installed yet. Smart pump with vfd on non pressurized ground...
  20. Replies
    11
    Views
    3,079

    30% of total system installed cost

    30% of total system installed cost
  21. Replies
    17
    Views
    3,482

    Why didn't you use ductless heads with water...

    Why didn't you use ductless heads with water coils means you have the w/w geo unit already.
  22. Replies
    3
    Views
    842

    Don't know if you got one yet but they are worth...

    Don't know if you got one yet but they are worth every penny. Ten times faster than screwing. I would by a new one, the new repeater pro doesn't screw the fasteners in like the old model faster and...
  23. Thread: FARM SHOP GEO

    by JCT
    Replies
    19
    Views
    2,707

    Thanks for all the great comments guys! Makes a...

    Thanks for all the great comments guys! Makes a guy feel good about what he is doing, I do take pride in what i do and what people think of finished product.:grin2:
  24. most units you can run right through i think. I...

    most units you can run right through i think. I know the northern heat pumps i put in you can they are rated for domestic.
  25. Thread: FARM SHOP GEO

    by JCT
    Replies
    19
    Views
    2,707

    SKYHEATING Thats the advantage of pro press...

    SKYHEATING
    Thats the advantage of pro press copper fittings speed. piping only took 1 day, 1 day for isulation 2 days for duct, setting equip, wiring, purging and startup. Duct is easy I made...
Results 1 to 25 of 95
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event