  1. I have seen this done with unitary equipment like...

    I have seen this done with unitary equipment like VAV's and Air Handlers. Example: if you selected to change from a parallel to a series PIU through a dropdown box either on the graphic itself or in...
  2. Replies
    49
    Views
    6,431

    All of the Mitsubishi compressors are variable...

    All of the Mitsubishi compressors are variable speed. From the residential Mr Slim to the largest commercial unit. I can't speak for Sanyo.
  3. Replies
    14
    Views
    1,906

    A JACE will not commision over LonIP.

    A JACE will not commision over LonIP.
  4. Replies
    9
    Views
    1,100

    I had a Transit Connect at my last job. I do not...

    I had a Transit Connect at my last job. I do not recommend them. We had several in the company and about 30% had transmission problems at 20,000 miles. Probably because they had more weight than what...
  5. You really need the Lutron guy there with you....

    You really need the Lutron guy there with you. They have to program their panel to expose bacnet. I spent several hours trying to bring in a Lutron panel only to discover they had not set up their...
  6. Based the info from DIGO, yes having the router...

    Based the info from DIGO, yes having the router installed will make a difference. Install the router as it was on the original system. From Spec Data:

    Communications:
    The W7751G uses a...
  7. 1. Have you commisioned the devices in LON?...

    1. Have you commisioned the devices in LON? Sometime just discovering does not do the trick.
    2. Discover some points and then do a bind.

    Another Question, when you discovered the devices what is...
  8. According to Honeywell's website they are FT-10 ...

    According to Honeywell's website they are FT-10

    http://customer.honeywell.com/honeywell/ProductInfo.aspx/W7751G1003
  9. Try installing the lonhoneywell jar file on your...

    Try installing the lonhoneywell jar file on your JACE and then rediscover the LON trunk and see if it matches any of the existing LMNL profiles. The fact that you are reading weird values means...
  10. Replies
    4
    Views
    536

    If it's a TNI, yes it is legacy CMnet. At least...

    If it's a TNI, yes it is legacy CMnet. At least 15 to 20 years old. Probably part of legacy migration to WebCTRL.
  11. Replies
    9
    Views
    997

    Check the JACE battery

    Most JACE's ride through power blips like that just fine. They all have an on board battery. If the battery is more than 2 to 3 years old it may need to be replaced. Check the diagnostics in the Jace...
  12. Replies
    26
    Views
    3,231

    Your programming issue lies between the chair and...

    Your programming issue lies between the chair and the keyboard.
  13. Replies
    4
    Views
    536

    Look under the network tree. The driver will be...

    Look under the network tree. The driver will be FB-15 under the CM number for the TNI card. On all legacy controllers used FB-15 for the drivers.
  14. Replies
    9
    Views
    1,097

    How many System 3 units do you have and what is...

    How many System 3 units do you have and what is the Vintage? Very old System 3s may not be able to take an IntelliSlot. Also is the SiteLink a "one part" (IGM ports on the bottom) or "two part" (two...
  15. Replies
    9
    Views
    1,097

    SiteLinks do not support SNMP directly. In the...

    SiteLinks do not support SNMP directly. In the past the best you could get was SNMP alarms via SiteScan Web for abnormal conditions. No operational data. In order to get SNMP data from Liebert units...
  16. Replies
    5
    Views
    993

    You may want to look at this site as well to make...

    You may want to look at this site as well to make sure. I just did one and I was able to see everything but to prevent local setpoint control and scheduling the documentation is essential....
  17. Replies
    1
    Views
    1,086

    Unless it is specified in the original contract,...

    Unless it is specified in the original contract, no that software is not routinely provided.
  18. Replies
    47
    Views
    6,890

    :ditto: I would add one more item, make sure all...

    :ditto:
    I would add one more item, make sure all the JACEs are "open" so that any Tridium dealer can access it.
  19. If you like Carrier you would LOVE...

    If you like Carrier you would LOVE AutomatedLogic's WebCTRL. WebCTRL is like i-VU on steriods.
    The reason the units continue to run is because they are LON based. On LON units, to occupy a unit the...
  20. Replies
    8
    Views
    698

    Check LON network connections

    Do you have an issue finding these guys in Rover? Make sure DSN A is showing up in Rover. If you can't find the controllers in Rover than you either have a bunch of bad controllers or more likely a...
  21. Have the chillers ever talked with Alerton? Or...

    Have the chillers ever talked with Alerton? Or were they part of Tracer Summit?
  22. Replies
    9
    Views
    936

    As of July 2011,( my last Spyder job I did before...

    As of July 2011,( my last Spyder job I did before changing jobs) Rapidbalance did work with standard apps. You need to get the latest and greatest from the Honeywell buildings website for both the...
  23. Replies
    26
    Views
    4,036

    Are you using the LMNL object from Tridium or did...

    Are you using the LMNL object from Tridium or did you discover the controller as a dynamic device? I have found out that depending on the vintage of the Trane device, the Tridium object is wrong and...
  24. Replies
    8
    Views
    752

    Most of the time the stop is included in the box...

    Most of the time the stop is included in the box with the actuator. If not than that kit would be right.
  25. Replies
    3
    Views
    419

    Try doing a "Clear Ram and Reset" on both BCU's....

    Try doing a "Clear Ram and Reset" on both BCU's. Also want to acknowlege and delete all the alarms if there are a bunch of them. BCUs are not very good memory managers and sometimes you need to free...