Fresh air intake?
Found this after a couple calls of No Heat that reset itself. Roofers covered the intake with asphalt and broke the fitting. I had to replace the whole concentric vent. :gah:
-
05-04-2012, 05:27 PM
Thread: 24 volt issue
by Greg414- Replies
- 12
- Views
- 541
You say you have 12 volts on "G" at the air...
You say you have 12 volts on "G" at the air handler. How are you testing this? Are you going G -> Common or G -> Ground or R -> G?.
If you have 12volts from G (wire from the tstat) -> Common with... -
05-03-2012, 11:44 PM
- Replies
- 6
- Views
- 1,228
Ugh, the thought of going into local restaurants...
Ugh, the thought of going into local restaurants makes me sick.
This IS prob the best way, or you can start off in the residential HVAC field, and work you way into the commercial refrigeration... -
05-03-2012, 11:19 PM
Thread: Anyone ever work for Trane /ingersol Rand
by Greg414- Replies
- 38
- Views
- 4,029
I work for Hussmann which is now owned by CD/R....
I work for Hussmann which is now owned by CD/R. Things are not as good as they can be, I find that the management sees and wants things in a way that is very difficult. Even when we were with Trane...
-
05-03-2012, 10:34 PM
Thread: My Service call problem.
by Greg414- Replies
- 5
- Views
- 688
My Service call problem.
Hey guys,
I wanted to share one of my service call problems because, well it stumped me so bad, that I feel like I need to pass the knowledge on. I'm sure most of you veteran techs may know this... -
05-03-2012, 03:50 PM
Thread: Compressors tripping
by Greg414- Replies
- 6
- Views
- 559
What refrigerant are you working with? What was...
What refrigerant are you working with?
What was the outdoor temp at the time of your pressure readings?
What is the superheat and subcool reading?
What is the suction pressure?
Does the condenser... -
02-16-2010, 03:27 PM
Thread: fluke 116 temp off
by Greg414- Replies
- 65
- Views
- 5,514
Fluke 116
I have had the same problem with my meter as well.
It only seems to be off in temp when it is very cold. I live in NH where outside temps can be very cold in the winter. When my meter is very cold,... -
08-18-2009, 11:54 PM
Thread: Split 3-ton A/C Problem
by Greg414- Replies
- 4
- Views
- 397
I rarely come to the fourms. I'm looking for a...
I rarely come to the fourms. I'm looking for a little help on what I am not seeing.
Are you not helping me because I have not submitted an EPA certification? -
08-18-2009, 09:41 PM
Thread: Split 3-ton A/C Problem
by Greg414- Replies
- 4
- Views
- 397
Split 3-ton A/C Problem
I went on a no A/C service call the other day.
I arrived, turned the a/c on, and then went in the attic to check the Fan, filter, and coil. Fan, filter, and coil were good. It was an orifice... -
05-30-2008, 07:02 PM
Thread: Problem with Split system
by Greg414- Replies
- 14
- Views
- 801
HV as in High Voltage? No this is a regular...
HV as in High Voltage?
No this is a regular Residential split 4 ton system. 208/230v with a programmable t-stat.
Trane AH
Trane Condenser -
05-29-2008, 10:51 PM
Thread: Problem with Split system
by Greg414- Replies
- 14
- Views
- 801
I'm working on scanning my Universial. Dam...
I'm working on scanning my Universial. Dam scanner is broken :/
-
05-29-2008, 10:45 PM
Thread: Problem with Split system
by Greg414- Replies
- 14
- Views
- 801
Problem with Split system
Hey,
I ran into a system today that was acting funny. It was short-cycling off the freeze stat in the attic for one, and the subcooling did not seem correct.
here are my numbers
R-22 w/ TXV
72F... -
05-29-2008, 08:07 PM
- Replies
- 16
- Views
- 3,371
That is how a thermostat works. What are you...
That is how a thermostat works. What are you expecting of it? Do you think it records the temp rising and compensates to keep the temp low?
Many Thermostats are different, lets say If you set the... -
Last week was the 1st week I have been on-call...
Last week was the 1st week I have been on-call for My Company. I waiting to see if i was compensated. If not I will continue with my regualr personal life, and if my pager goes off and i'm drinking...
-
05-23-2008, 05:14 PM
Thread: Service Tec Tool List
by Greg414- Replies
- 57
- Views
- 4,543
I never asked them, but I'm sure they will not...
I never asked them, but I'm sure they will not cover them if I get fired or quit. I'm a long way from retiring so thats out of the question.
I'm def not going out of my way to get these asap. Our... -
05-22-2008, 07:18 PM
Thread: A/C unit as walk-in cooler???
by Greg414- Replies
- 10
- Views
- 3,568
View Post
Wouldn’t this take forever! Most contain R-22 right? If this air conditioner worked correctly, air going threw the evap would be so cold the refrigerant would not evaporate causing a flood-back to...
-
05-22-2008, 07:03 PM
Thread: Oil vesus Propane
by Greg414- Replies
- 12
- Views
- 438
Nice job :D
Nice job :D
-
05-22-2008, 06:47 PM
Thread: Oil vesus Propane
by Greg414- Replies
- 12
- Views
- 438
I would not suggest a heat pump in New York, its...
I would not suggest a heat pump in New York, its not very efficient in the winter. Then again if its for tenants, they will be paying the electric bill.
IMO, I like Propane better because it is... -
05-22-2008, 06:38 PM
Thread: A/C unit as walk-in cooler???
by Greg414- Replies
- 10
- Views
- 3,568
I would think they would need to change the type...
I would think they would need to change the type of refrigerant, metering divice, and maybe the compressor. Than add a condenser fan cycling switch. Maybe a freeze stat with a defrost heater.
Ya... -
05-22-2008, 06:32 PM
Thread: World Clock
by Greg414- Replies
- 5
- Views
- 487
View Post
Wow that’s kind of interesting
Military expense, I LOLed
I didn’t realize people are dieing that quick, kinda sad. -
05-22-2008, 06:14 PM
Thread: Service Tec Tool List
by Greg414- Replies
- 57
- Views
- 4,543
I talked to my Service manager today. After...
I talked to my Service manager today. After showing him a quote for $1,300 on just the questionable Company/Tech supplied tools
He decided to remove the...
Refrigeration Oil Pump ~ $80
Acetylene... -
I am on call every 3rd week. If my weekly hours...
I am on call every 3rd week.
If my weekly hours go over 40 I get OT (time + time-in-half) for the remaining hours i worked. I do not recieve any compensation, but im working on it :D . -
05-21-2008, 04:50 PM
Thread: Open Position Mass
by Greg414- Replies
- 2
- Views
- 585
Hey Hvacmanager, What are you looking for...
Hey Hvacmanager,
What are you looking for exactly?
How many years experience?
What kind of commercial? Light, medium, heavy?
I might be interested. -
05-20-2008, 08:43 PM
Thread: Service Tec Tool List
by Greg414- Replies
- 57
- Views
- 4,543
Thanks for the input guys, I'm going to talk with...
Thanks for the input guys, I'm going to talk with my Service manager and discuss this further.
I would def like to have some if not all of these tools for my personal use some day but, I don’t feel... -
05-20-2008, 07:21 PM
Thread: Service Tec Tool List
by Greg414- Replies
- 57
- Views
- 4,543
What about the Torch Kit, Tank, and Tips?
What about the Torch Kit, Tank, and Tips?