  1. the original install was good that I can tell....

    the original install was good that I can tell. The unit as in all cases with case coils are like a seperate unit as you know so the case coil and blower were install correctly. I replaced coil due...
  2. Amana Heat Pump with a CASE COIL Air Handler issue

    First of all I have never seen a set up like this. CASE COIL on a Heat pump here in Fla??? I changed out the coil in the air handler due to a leak and the unit is 3 yrs old. I did everything that...
  3. Replies
    69
    Views
    7,099

    I could not watch the whole thing so he did vac...

    I could not watch the whole thing so he did vac it down.... I was like hell no I am not wasting my time watching another seg of this guy trying to act like he knows what the hell he is doing.... If...
  4. Replies
    29
    Views
    3,407

    yes there is a flare and there is a perfectly...

    yes there is a flare and there is a perfectly good piston in it please read the first one where it states that I did take the piston out and flushed the entire system out with nitrogen. I checked...
  5. Replies
    29
    Views
    3,407

    Yeah so am I but its a rental prop and this guy...

    Yeah so am I but its a rental prop and this guy is a real jerk. I mean it is not even that cold out like today it is 68 and he wants his landlord to pay for a stay in the hotel for over night. It...
  6. Replies
    29
    Views
    3,407

    sounds like the reversing valve is working I did...

    sounds like the reversing valve is working I did wack it a few times but it does sound like it is working... Cap tubes I am leaning on that too but right now after going over and over it sounds like...
  7. Replies
    29
    Views
    3,407

    I have to check it out tmw. The liquid pressure...

    I have to check it out tmw. The liquid pressure in this case is 164 going into the system the gas coming out of the ahu drops to 21 at the condenser service valve... So that is why I am saying that...
  8. Replies
    29
    Views
    3,407

    Eco Temp is ICP Carrier product.... CHEAP one.......

    Eco Temp is ICP Carrier product.... CHEAP one.... IT has a TXV Lennox ahu and I changed it out when the condenser was installed. Mechanical device so no braising was needed. Could be bad check...
  9. Replies
    6
    Views
    1,239

    with the information provided cant really help...

    with the information provided cant really help ya. Could be installer did not install correctly... Did you check filter or coil (AHU) to see if they were dirty.... Possible txv issue but I doubt it...
  10. Replies
    29
    Views
    3,407

    yes and this is what I am getting...... I have...

    yes and this is what I am getting...... I have done everything correct... Been in this field for 12 years so all the things that were suppose to be done was done correctly. That is why I also put...
  11. Replies
    69
    Views
    7,099

    omg that is sooooo funny what the hell and he had...

    omg that is sooooo funny what the hell and he had the balls to put this on line. PLEASE I hope that guy is not in jacksonville fla because I think I have seen some of his work before....... toooo...
  12. Replies
    29
    Views
    3,407

    Heating Issue with a Heat pump in heat mode.

    Working on an r22 pos eco temp in cooling mode high side 198 low side 62 its about 75 inside. Switch it to heat mode and the common port drops to 6 psi cap tubes freeze up. 3/4 side goes to 165 and...
  13. Thread: SMAN or Testo?

    by toyo066
    Replies
    147
    Views
    19,966

    aint that the truth.. alot of techs will say that...

    aint that the truth.. alot of techs will say that they know how to do sub cool and superheat and come to findout that they dont.
  14. Thread: New Dremmels

    by toyo066
    Replies
    6
    Views
    1,103

    Youtube

    Dremel
    Multi-Max 2.3-Amp Oscillating Tool Kit the Rotary one sucks. It throws crap into your face this one cuts like butter and you dont have to worry about the spinning of the blade it just...
  15. Replies
    93
    Views
    12,598

    101

    101
  16. Replies
    15
    Views
    1,733

    410a it's a Must

    when using 410a it is the only way to go. if you are short on just one pound of Puron you could lose up to 4 degrees cooling. The only way to get it right is your SC and SH if your having an issue...
  17. Replies
    38
    Views
    4,202

    Not in this Country. You sadly are mistaking sir.

    Not in this Country. You sadly are mistaking sir.
  18. Thread: New Dremmels

    by toyo066
    Replies
    6
    Views
    1,103

    New Dremmels

    Ever run into those Lennox coil leaks on the condenser unit??? The dremmel is the best tool to use to take care of this issue. Cut out some fins and then cut to copper line, insert a piece of 3/8...
  19. Thread: x-13 motors

    by toyo066
    Replies
    0
    Views
    449

    x-13 motors

    Has anyone ever used the x13 surge protectors and if so doesthe surge protector stop these damn things from burning up.... POS I have had about 6 of these things go on me within 3 weeks and there...
  20. Thread: SMAN or Testo?

    by toyo066
    Replies
    147
    Views
    19,966

    Never had an issue I would write Field Piece and...

    Never had an issue I would write Field Piece and tell them and send the SR# they should know when you purchased it. The only issue I had with it was the hanging hook it broke but other then that I...
  21. Thread: SMAN or Testo?

    by toyo066
    Replies
    147
    Views
    19,966

    ditto

    Yeah i am waiting for the 4 to come out soon but I aint jumping to buy it I will wait 6 months. Price will be high.
  22. Thread: SMAN or Testo?

    by toyo066
    Replies
    147
    Views
    19,966

    SMAN 3 VS TESTO

    SMAN 3 IS BETTER HANDS DOWN. I HAVE BOTH OF THEM AND THE WAY THEY BOTH DO THE SUBCOOLING AND SUPERHEAT i HAVE TO GIVE IT TO SMAN 3. PLUS THE TEMP CLIPS ON THE SMAN3 LAST A WHOLE LOT LONGER. THEY...
  23. Replies
    15
    Views
    2,834

    R-22

    I am aware of the EPA statement and what will be done as far as elimination is concerned, what I was getting at is that some SUPER TECH told me that you no longer as of 2014 can do any repairs on the...
  24. Replies
    15
    Views
    2,834

    R-22 EPA REG 2014

    I have been looking to see if this is real or just same old gossip... Come 2014 the EPA is banning R-22. What I have heard is that if a customer has a leak in the system that we are not going to be...
  25. Replies
    39
    Views
    6,291

    I love it and have been using it for about 6...

    I love it and have been using it for about 6 months, good price check out youtube and put in testo 550 and see what some tech's have learned about it... Pretty helpful things.
  26. 50 microns or 500 microns.... big diff there.....

    50 microns or 500 microns.... big diff there.. 500 is what it should have been for 45 min he must have a sorry vac, but he could have meant 500... You should be okay if it's 500 microns oxygen does...
  27. Replies
    73
    Views
    3,891

    I knew a person who got involved in the HVAC...

    I knew a person who got involved in the HVAC industry and he was a complete idiot... If he could do it, I could do it... The question is HOW GOOD!
  28. Replies
    40
    Views
    6,313

    chaching chaching for the correct work thank you.

    chaching chaching for the correct work thank you.
  29. Rx11

    make sure they flush it with RX 11 and blow it out with nitrogen. It is the only way. If you dont do this then you will be paying for txv valves and possible compressor down the road. Best bet is...
  30. Thread: LABOR QUESTION

    by toyo066
    Replies
    13
    Views
    1,672

    LABOR QUESTION

    I work for a company here in fla and we use to do piece work. They have changed over to hourly pay but they dont want to pay for travel time between jobs. Nor do they want to pay you hourly rate...
  31. G61v

    I have heard all three and the Lennox has it but not by much I doubt you would even know the diff if you was in your home trying to listen for it... THat is unless you have paper walls......
  32. What!

    Moe, Larry And Curly! Three Stooges A/c Repair Company!
  33. Thread: Trane Issue

    by toyo066
    Replies
    17
    Views
    2,385

    They have several exhaust fans and two of the...

    They have several exhaust fans and two of the them blew a belt. They failed to tell me that.... I guess I need to speak Japanese I think so.... NOT!
  34. Thread: Trane Issue

    by toyo066
    Replies
    17
    Views
    2,385

    It is a Japanese Steak house and they cook right...

    It is a Japanese Steak house and they cook right under the damn return... I have told them that they need to move the return, now they understand why.... Other then the cooling issue that you have...
  35. Thread: Trane Issue

    by toyo066
    Replies
    17
    Views
    2,385

    The problem was the smoke detector, I pressed the...

    The problem was the smoke detector, I pressed the re-set button and it came on... Thanks for the help... Check is in the mail...
  36. Thread: Trane Issue

    by toyo066
    Replies
    17
    Views
    2,385

    The extra stat wires probably go to the...

    The extra stat wires probably go to the fire/smoke detector. Look

    changed out board, yes, I do lack it here, never worked on a unit like this.... the stat is the same stat that was on the unit...
  37. Thread: Trane Issue

    by toyo066
    Replies
    17
    Views
    2,385

    Trane Issue

    I am working on a Trane Voyager (Spelling??) The customer thought that it was the t-stat so he changed it out this t-stat does not work with 24v it is ohms and that seems not to be the problem......
  38. Thread: R410A Question

    by toyo066
    Replies
    6
    Views
    1,249

    I have heard a few different things from other...

    I have heard a few different things from other tech's but they dont have the experience with the 410... However, if you do it by the scale that is cool when it is empty, but what took place was we...
  39. Replies
    14
    Views
    1,473

    try running a hose over the compressor for about...

    try running a hose over the compressor for about 15 to 20 min... It could take a few hours.
  40. Replies
    56
    Views
    3,787

    185.32

    185.32
  41. Thread: R410A Question

    by toyo066
    Replies
    6
    Views
    1,249

    R410A Question

    I have a question on this... I am trying to figure out the temps and all that with R410.... We had a mini split to install today which was a R410 system... On these units you have NO liquid side to...
  42. Replies
    19
    Views
    1,704

    That seems to be the case with most units.......

    That seems to be the case with most units.... Fans stick, either from lack of high voltage or the Blower Relay... Carrier has a unit that if it lacks high voltage it stays on all the time in low...
  43. Replies
    17
    Views
    2,036

    your Dust may not be an issue with the Air...

    your Dust may not be an issue with the Air handler... The filter is protecting the air handler and the coils... You my want to look at your copper lines going into your air handler and seal them...
  44. Unless I hear some amazing anecdotal stories...

    Unless I hear some amazing anecdotal stories about how bad the rheem/rudd systems are I am going with the Mod 90+ furnace, the contour comfort stat and a skuttle humidifier.

    Can't Go Wrong!!!!!
  45. Replies
    19
    Views
    1,704

    What do you have a heat pump or gas????? If it is...

    What do you have a heat pump or gas????? If it is a heat pump it sounds like the blower relay board in the air handler......
  46. Replies
    3
    Views
    762

    I am saying from the best to the worse... I am...

    I am saying from the best to the worse... I am sure your just being sarcastic, just as I am but they are the worse and as a Tech here in Florida, I know this from experience....... Thanks for the...
  47. Replies
    3
    Views
    762

    looking for the Call Back list....

    I saw on here about 2 months ago a list for call backs or rather a list of the units, I think it was by percentage on the call backs that each company had... Like American Standard was number 1 then...
  48. I stand corrected... That is what I get for...

    I stand corrected... That is what I get for listen to a counter person....
  49. The manufactures have to provide replacement...

    The manufactures have to provide replacement parts for up to 2 years.... So that includes the compressors too. After that it is a new ball game.....
  50. Replies
    17
    Views
    2,115

    WRONG LINE DRIER!!!!!

    I went to check the unit out today and guess what I found on for a line drier???? A STRAIGHT COOL drier.... We took it off and what a surprising thing.... It was working like a charm.... Not to say...