  1. a fan motor will only turn at it synchronous...

    a fan motor will only turn at it synchronous speed, minus slip, so it wont exceed it's rated load, would draw more if the pitch of the fan was too much and it was trying to move too much air
  2. Replies
    26
    Views
    2,138

    high resistance short, A short is a short, has to...

    high resistance short, A short is a short, has to be repaired
  3. Replies
    26
    Views
    2,138

    the difference is.....if you took the coil of...

    the difference is.....if you took the coil of wire out of the motor and streched it in a straight line drove a ground rod, connected it to 220 it would light up like a filiment in a bulb and burn up,...
  4. Replies
    26
    Views
    2,138

    one guy said the compressor coulod run forever...

    one guy said the compressor coulod run forever there is no gfci, another said the breaker was bad, I just saying if the compressor winding is shorted the breaker should trip nothing fancy, if it...
  5. Replies
    26
    Views
    2,138

    there is no ground, any breaker will trip if the...

    there is no ground, any breaker will trip if the winding is shorted to the compressor if the compressor is properly grounded. Has nothing to do with gfci, go figure, that's why the service ground is...
  6. Replies
    4
    Views
    553

    12 thhn good for 20 amps in my code book, the...

    12 thhn good for 20 amps in my code book, the only time it's good for more is to a motor
  7. Replies
    4
    Views
    553

    Not hvac but...

    hooking up a water heater, plainly stated on paperwork and unit must be no. 10 copper, open the heater and two no. 12's must be nice.
  8. Replies
    42
    Views
    3,328

    licensed plumber is right to add to a vent, a...

    licensed plumber is right to add to a vent, a vent doesent become a "wet vet just because you add a drip to it, go figure, any way a plumbing change might change the fixture load of the system....do...
  9. Replies
    42
    Views
    3,328

    if you run water to it it isn't a vent anymore,...

    if you run water to it it isn't a vent anymore, broke the code
  10. Replies
    42
    Views
    3,328

    it can go to the sewer, but it has to be a...

    it can go to the sewer, but it has to be a indirect connection
  11. Replies
    30
    Views
    1,896

    a 230 volt motor draws one half the amps same hp

    a 230 volt motor draws one half the amps same hp
  12. Replies
    30
    Views
    1,896

    no a 120 volt motor at reduced voltage draws less...

    no a 120 volt motor at reduced voltage draws less amps
  13. Replies
    30
    Views
    1,896

    NO, LESS voltage less amps

    NO, LESS voltage less amps
  14. Replies
    30
    Views
    1,896

    not so still single phase, just 240 volt if one...

    not so still single phase, just 240 volt if one phase goes out the voltage would only decrease
  15. Replies
    21
    Views
    1,575

    to change out a unit we are required to get a...

    to change out a unit we are required to get a permit, at least only one inspector come for the mech. and electrical
  16. Replies
    63
    Views
    3,798

    I carry my license with me and have a number for...

    I carry my license with me and have a number for my insurance
  17. Replies
    47
    Views
    5,045

    I guess the next time you get a headache you'll...

    I guess the next time you get a headache you'll be doing brain surgery, good luck, I hope you sleep well know a hack worked on your system, I do what I am trained to do nothing else.
  18. Replies
    47
    Views
    5,045

    yea they charge more for that but with the adding...

    yea they charge more for that but with the adding of tankless water heater might be more, out on a call now a diy homeowner, he replaced all the limit switches trying to repair his heat, now he's...
  19. Replies
    47
    Views
    5,045

    what does driving a train have to do with it?

    what does driving a train have to do with it?
  20. Replies
    15
    Views
    1,946

    that's one reason all the old mills had three...

    that's one reason all the old mills had three llights in the maintenance shop
  21. Replies
    47
    Views
    5,045

    yes after 30 years of electrical work

    yes after 30 years of electrical work
  22. Replies
    15
    Views
    1,946

    no, you never disconnect the neutral unless...

    no, you never disconnect the neutral unless gasoline is involved
  23. Replies
    47
    Views
    5,045

    call an electrican before you blow someone up

    call an electrican before you blow someone up
  24. Replies
    15
    Views
    1,946

    delta three phase is 120 degrees out of phase...

    delta three phase is 120 degrees out of phase with each other, with no neutral, the wye has a neutral, if it is three phase delta, not one of the conductors is grounded, you are going to hurt...
  25. Replies
    17
    Views
    1,974

    hope you're using the circuit breaker 3 amp they...

    hope you're using the circuit breaker 3 amp they sell it at the supply house wont burn out the transformer
  26. Replies
    31
    Views
    3,317

    a small dent in the line or add a fitting and...

    a small dent in the line or add a fitting and have to braze in one, two places, with out a bending tool some people "kink the large line and dont think anything about it unless the "kink" is really...
  27. Replies
    85
    Views
    4,852

    what about the esco cert? they are testing the...

    what about the esco cert? they are testing the local maint guy's here
  28. Replies
    13
    Views
    8,096

    wheatstone bridge is what I have used to test the...

    wheatstone bridge is what I have used to test the windings, a fluke will test the windings to ground, there shouldn't be a reading, some of the old meggers hand crank type sometime caused more...
  29. Replies
    17
    Views
    1,243

    car batteries are 200 amps and they wont hurt you?

    car batteries are 200 amps and they wont hurt you?
  30. Replies
    17
    Views
    1,243

    ok what kills ya volts or current

    ok what kills ya volts or current
  31. Replies
    8
    Views
    679

    gc's aren't hvac licensed, you couldn't legally...

    gc's aren't hvac licensed, you couldn't legally do ther work anyway, get your hvac license, or leave it to the pro's
  32. Replies
    166
    Views
    11,526

    maybe the condenser is gone, they stealin them...

    maybe the condenser is gone, they stealin them now, had one missing yesterday, took most of the line set too
  33. Replies
    15
    Views
    1,287

    Huh? maintenance guys

    Huh? maintenance guys
  34. Replies
    15
    Views
    1,287

    here we used to call in to get permits, now we...

    here we used to call in to get permits, now we call a computer, using our contractor code, people were stealing them and now we have a pin number, what's next finger prints and dna?
  35. Thread: Concord

    by bltinnc
    Replies
    7
    Views
    678

    they are selling the house and didn't want to...

    they are selling the house and didn't want to install new 13 seer inside coil
  36. Thread: Concord

    by bltinnc
    Replies
    7
    Views
    678

    ok thanks, i've got a 10 seer, new to hook up,...

    ok thanks, i've got a 10 seer, new to hook up, they got it at a auction
  37. Thread: Concord

    by bltinnc
    Replies
    7
    Views
    678

    ok thanks, came across one today, wasn't sure

    ok thanks, came across one today, wasn't sure
  38. Thread: Circuit finder

    by bltinnc
    Replies
    8
    Views
    893

    the one I have cost about 80 bucks

    the one I have cost about 80 bucks
  39. Thread: Circuit finder

    by bltinnc
    Replies
    8
    Views
    893

    there is a cheap greenlee I have plugs into the...

    there is a cheap greenlee I have plugs into the circuit and follows to the panel, or sometimes I use the telephone wire tracer woks great on any wire less than 1000 ft, with the power off, if I cant...
  40. Thread: Concord

    by bltinnc
    Replies
    7
    Views
    678

    Concord

    anyone have any thoughts on concord condensors, 1.5 ton split
  41. Replies
    45
    Views
    11,051

    well as I said not heard of any problems after...

    well as I said not heard of any problems after the fact and we bend it all the time to go around corners, I seen it kinked many times pulled through walls and attics, but that's just me
  42. Replies
    45
    Views
    11,051

    of course the code say's you can't bend it that...

    of course the code say's you can't bend it that way. but i've never heard of a problem after the fact of a run like that someone poulled through an attic and didn't see it for instance
  43. Replies
    45
    Views
    11,051

    if you stretche the romex that is something...

    if you stretche the romex that is something altogether different, if it's bent and the guage is the same there wont be a loss of copper area
  44. Replies
    45
    Views
    11,051

    I know on coax a kink is a problem, changes...

    I know on coax a kink is a problem, changes impedence, on romax I don't relly see a problem, not like a water hose
  45. they have a relay that breaks to circuit from the...

    they have a relay that breaks to circuit from the thermostat that cuts the condensor just you would if you cut the heat or ac, or it was satisfied....course they might cut it off on the hottest day r...
  46. works ok if you want to save, I've seen it both...

    works ok if you want to save, I've seen it both ways 24 vac and 240 vac, both had a time delay not to damage the compressor, so it could equalize, they do water heaters too...
  47. great list

    great list
  48. Replies
    18
    Views
    1,995

    yea I got the magnetic hanger love it, is...

    yea I got the magnetic hanger love it, is everyone going to the arc fault rated?
  49. Thread: oh well

    by bltinnc
    Replies
    4
    Views
    542

    4 ton condenser to a 2 ton coil, what would...

    4 ton condenser to a 2 ton coil, what would happen?
  50. Thread: oh well

    by bltinnc
    Replies
    4
    Views
    542

    unless the freon is precharged that won't work

    unless the freon is precharged that won't work
Results 1 to 50 of 200
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event