  1. Replies
    2
    Views
    583

    thank you so much dandyme

    thank you so much dandyme
  2. Replies
    2
    Views
    583

    48LDT006610da w/d

    hey I really need a wiring diagram for carrier 48ldt006610 just the gas heat side, thx
  3. spider web in manifold and or orifices

    spider web in manifold and or orifices
  4. Thread: pressure test

    by joebear
    Replies
    18
    Views
    2,091

    thanks for the reponse

    thanks for the reponse
  5. Thread: pressure test

    by joebear
    Replies
    18
    Views
    2,091

    pressure test

    repaired leak in 10 ton rtu,left 200 psi nitrogen,temp. at that time was 48 deg. going back tomorrow temp.supose to be in the teens, a little r22 was left in with nitrogen,will my pressures be lower...
  6. hey thx looks like jade may be easy retro

    hey thx looks like jade may be easy retro
  7. so silkbus sensor for my enthapy and different...

    so silkbus sensor for my enthapy and different one for mixed air?
  8. whats the silkbus sensor

    whats the silkbus sensor
  9. I need to retrofit econmiozer on a 10ton carrier,...

    I need to retrofit econmiozer on a 10ton carrier, want sensors do I need with the jade
  10. Replies
    25
    Views
    1,510

    any comments on the new h10pro model from...

    any comments on the new h10pro model from bacharach
  11. Replies
    2
    Views
    309

    carrier edge tstat e1 error code

    carrier dual fuel package 48xt0360903, changed 3 edge tstats in 3 years, anybody know of any problems
  12. Replies
    54
    Views
    5,816

    united ref.,nrp,beacon,whatever, has sold us out...

    united ref.,nrp,beacon,whatever, has sold us out to the Chinese,all this junk is junk!
  13. Replies
    54
    Views
    5,816

    while im here united ref.,nrp,beacon, what ever...

    while im here united ref.,nrp,beacon, what ever has sold us out to china,they should be ashamed for what they have done
  14. Replies
    54
    Views
    5,816

    yellow jacket only, nrp is china junk

    yellow jacket only, nrp is china junk
  15. Replies
    6
    Views
    725

    I love my testo 557's, I don't know why you guys...

    I love my testo 557's, I don't know why you guys hate testo so much
  16. Replies
    5
    Views
    545

    take backside panel off and you got it,unless...

    take backside panel off and you got it,unless shaft is whiddled down
  17. Replies
    36
    Views
    3,135

    when I started this thread I had in mind but...

    when I started this thread I had in mind but didn't say it right, analog meters



    when I started this thread my mind was on analog meters mostly, simpson 260, amprobe rs3, and analog temperature...
  18. Replies
    36
    Views
    3,135

    exactly, when we retire its all gone,they wont...

    exactly, when we retire its all gone,they wont know. im doing it for myself like a retrospect of my career
  19. are you sure this coil dosent have multiple...

    are you sure this coil dosent have multiple orifices feeding it,trane has problems with these clogging
  20. Replies
    36
    Views
    3,135

    go back to analog for a week

    just for fun why don't we all go back to analog gauges,amprobe,multimeter,and temperature meter for a week. I work with several young guys that never seen a real amprobe before. yall probably will...
  21. Replies
    76
    Views
    4,878

    what tricks do you guys have for replacing heat...

    what tricks do you guys have for replacing heat exchangers on larger tonnage sunlines like 15 tons
  22. Replies
    1
    Views
    468

    york prestige rtu

    has anyone installed the new York prestige exact fit rtu yet? any good or bad features?
  23. Thread: pneumatics

    by joebear
    Replies
    12
    Views
    844

    ok thanks,im in va. and most older buildings are...

    ok thanks,im in va. and most older buildings are designed to fail to heat,but I have seen 3 somewhat newer buildings fail to cool,never seen or heard of that
  24. Thread: pneumatics

    by joebear
    Replies
    12
    Views
    844

    pneumatics

    will somebody explain how most pneumatic blbgs fail to heat but some fail to cool
  25. Replies
    76
    Views
    4,878

    one trick I have done on the larger sunlines to...

    one trick I have done on the larger sunlines to get the heat exchanger out is to use a hydraulic portapower to spread the sheet metal walls apart so you can lift exchanger out
  26. Replies
    11
    Views
    1,607

    stay away from uei,i have heard bad things,i have...

    stay away from uei,i have heard bad things,i have the Bacharach insight and I like it a lot,easy to use
  27. Replies
    24
    Views
    2,207

    r.e. michels has them on sale with clamps for...

    r.e. michels has them on sale with clamps for $298.00
  28. Replies
    8
    Views
    1,186

    guess its time for the sman5

    guess its time for the sman5
  29. Replies
    12
    Views
    1,151

    check smoke detector and all pressure switch...

    check smoke detector and all pressure switch wires for rub thru to copper
  30. Replies
    6
    Views
    626

    York is the worst by far

    York is the worst by far
  31. Replies
    56
    Views
    5,941

    im going to digicool ak900 and bluvac!!!!!!!!!!

    im going to digicool ak900 and bluvac!!!!!!!!!!
  32. Replies
    35
    Views
    4,534

    does a b4vm36 ahu match with a 3.5 ton outdoor...

    does a b4vm36 ahu match with a 3.5 ton outdoor unit?
  33. Replies
    30
    Views
    6,733

    lytning, what did you pay for the uei,bluvac

    lytning, what did you pay for the uei,bluvac
  34. Replies
    56
    Views
    5,941

    I did a side by side comparison, testo557 with...

    I did a side by side comparison, testo557 with two other micron gauges and the testo was reading 10000 microns high?!
  35. Replies
    35
    Views
    4,534

    what rh% do you have in house now

    what rh% do you have in house now
  36. Replies
    8
    Views
    956

    ok thanks

    ok thanks
  37. Replies
    8
    Views
    956

    question for Russell, I want a sman4 and sdp2 so...

    question for Russell, I want a sman4 and sdp2 so I can sync wet bulb, what do I need to sync oddb,or do you just enter it manually
  38. Replies
    18
    Views
    1,424

    I called testo, I had the psig scale on the...

    I called testo, I had the psig scale on the screen,you have to use psia absolute to measure mircons on 557,but like others have said the micron gauge is not very reliable when comparing to another...
  39. Replies
    18
    Views
    1,424

    it only stays at 000

    it only stays at 000
  40. Replies
    18
    Views
    1,424

    I love em too except for micron reading and hook

    I love em too except for micron reading and hook
  41. Replies
    18
    Views
    1,424

    yea, I only get 000

    yea, I only get 000
  42. Replies
    18
    Views
    1,424

    there is no escape

    there is no escape
  43. Replies
    18
    Views
    1,424

    testo 557 vacuum reading

    I cant seem to get my 557s to read microns when pulling a vacuum,what am I doing wrong?
  44. Thread: gauges

    by joebear
    Replies
    26
    Views
    2,803

    2 analog for 22, 2 analog for 410, testo557, and...

    2 analog for 22, 2 analog for 410, testo557, and stubbys
  45. Thread: 1974

    by joebear
    Replies
    16
    Views
    1,356

    we called them watermelons here

    we called them watermelons here
  46. mcdonalds are notorious for small or restricted...

    mcdonalds are notorious for small or restricted duct work,the stores I have serviced had 15 ton units in the kitchens
  47. Replies
    39
    Views
    4,234

    had to send my appion plungers back also

    had to send my appion plungers back also
  48. Replies
    8
    Views
    621

    I was also taught with vac on run caps,you can...

    I was also taught with vac on run caps,you can always go up but not down,but talked to local motor rebuild shop owner and he said 370vac run caps are better than 440vac,he said they have less...
  49. Replies
    61
    Views
    4,772

    this stuff {r22 replacements} is going to get out...

    this stuff {r22 replacements} is going to get out of hand,with so many flavors now and everybody using different ones and no one marking on the unit what juice is inside,how many flavors you gotta...
  50. Thread: Damage control

    by joebear
    Replies
    14
    Views
    2,077

    that's a safety concern with infection from...

    that's a safety concern with infection from pigeon poop