Search:

Type: Posts; User: chadtech

Page 1 of 8 1 2 3 4

Search: Search took 0.01 seconds.

  1. A station backup contains the station.

    A station backup contains the station.
  2. Replies
    6
    Views
    1,006

    Email sent. New construction. Thanks for your...

    Email sent.

    New construction. Thanks for your help!
  3. Replies
    6
    Views
    1,006

    manual J & D help

    Anybody willing to help me out with a manual j and d on my new house I'm building. Its been many years since I've done a calc by hand, I've looked at buying software, but, ouch $400 and I'm only...
  4. Replies
    13
    Views
    1,135

    I'd like to have those also. If you would please...

    I'd like to have those also. If you would please send them to me.
  5. Replies
    1
    Views
    329

    Niagara Energy Star Portfolio manager

    I am searching for an AX driver that can automatically push meter data to Energy Star Portfolio manager. Anybody seen or heard of such?

    Thanks!
  6. Replies
    11
    Views
    964

    Infocon sold the driver division to Maxline...

    Infocon sold the driver division to Maxline Solutions. There have been many updates to the comm4 driver. What version driver are you using. I used it on several jobs in the past few months with...
  7. Replies
    4
    Views
    488

    http://csicubed.com/portfolios/csv-driver/ ...

    http://csicubed.com/portfolios/csv-driver/

    I've used this driver before. Works pretty well. Not sure if this is what your looking for.
  8. Replies
    15
    Views
    1,148

    Be careful about how often you writing to CCN...

    Be careful about how often you writing to CCN points also. I had a job once where we were writing to the chilled water setpoint too often (reset) and it caused the Carrier controls on the chiller to...
  9. Replies
    10
    Views
    861

    Download the Trane Tracer BACnet Setup tool. From...

    Download the Trane Tracer BACnet Setup tool. From here:

    http://www.tranecds.com/COMMERCIAL/DesignAnalysis/DownloadCenter.aspx?i=909&p=18

    Plug into the white Trane BACnet UC400 using USB cable...
  10. Replies
    9
    Views
    1,406

    Sorry to bring this old thread up but I wanted to...

    Sorry to bring this old thread up but I wanted to clarify. I have a SiteLink 12 without a 2MB label. Its currently communicating modbus out of port B.

    Is it possible for this Sitelink to be...
  11. Replies
    4
    Views
    408

    I have the same legitimate complaint about the...

    I have the same legitimate complaint about the Niagara nav file. I have built my own HTML tree similar to the one in the demo station, although it has its limitations too. Let us know if you find a...
  12. Thread: Trucks

    by chadtech
    Replies
    23
    Views
    1,875

    I knew it was just a matter of time. I thought...

    I knew it was just a matter of time. I thought it was funny hence the reason I didn't correct it.:cheers:
  13. Thread: Trucks

    by chadtech
    Replies
    23
    Views
    1,875

    I think mechmike is referring to the nv200. ...

    I think mechmike is referring to the nv200. Those things are ugly as the north end of a southbound donkey! I drive a Ford Transit Connect and it works well, had to modify the dividing partition in...
  14. Replies
    7
    Views
    1,005

    If the OSS is in the jace, how do you get it up...

    If the OSS is in the jace, how do you get it up to the supervisor to put on a px?
  15. Replies
    14
    Views
    1,231

    :beat: PM me if you need local support.

    :beat:


    PM me if you need local support.
  16. Replies
    3
    Views
    546

    Trane COMM3 CSC

    Attention Trane guys. Interested in what is Trane's solution to older (1997) CSC units with the blue LED display that will only communicate Trane COMM3, am I correct that the new BCUs will no longer...
  17. This should be an easy panel to setup and wire. ...

    This should be an easy panel to setup and wire. I find it hard to believe that you can't easily find a contractor capable of getting this simple system working. Was the zone panel working before...
  18. Please share. Email in my profile.

    Please share. Email in my profile.
  19. Replies
    10
    Views
    954

    Keith, could I get a copy of the .bog also. I've...

    Keith, could I get a copy of the .bog also. I've always struggled to understand how to totalize data and put it into a report.

    Thanks!
  20. Replies
    8
    Views
    786

    Is it on a communication network? If so the...

    Is it on a communication network? If so the password is viewable and editable via the network. Otherwise I don't know of a way to reset the password.
  21. Replies
    11
    Views
    904

    My opinion.....Required-no, Recommended yes. I...

    My opinion.....Required-no, Recommended yes. I always at the end of a installation project go to the Lon device manager and highlight all devices, (even the local Lon device) and commission them,...
  22. Replies
    19
    Views
    1,603

    Oops forgot the attachment......438061

    Oops forgot the attachment......438061
  23. Replies
    19
    Views
    1,603

    MatrixTransform, I have been doing some digging...

    MatrixTransform, I have been doing some digging on this today and I have been able to get the hyperlink working but still can't figure out how to display the history chart on the relativized px. See...
  24. Honeywell Spyder Calculating suction gas superheat

    The question is whats the best way you can think to get the saturated suction temperature for the superheat calc.
  25. Replies
    5
    Views
    802

    Went to the job site today and reconnected the...

    Went to the job site today and reconnected the jace 485 and tried to duplicate the scenario and of course was unsuccessful. The chiller has been running fine for almost 2 weeks without the jace...
  26. I think you should get your facts straight before...

    I think you should get your facts straight before throwing rocks. Honeywell doesn't charge ANY extra for a Webs open license. And the spyder ILC are needed only when using the SpyderTool on a JACE...
  27. Replies
    5
    Views
    802

    When the display goes blank it shows only the...

    When the display goes blank it shows only the Carrier emblem (the one that circles the problem)! I think that is the screen it shows on boot up. I haven't been onsite to troubleshot yet, other...
  28. Replies
    5
    Views
    802

    No one has successfully used the CCN driver?

    No one has successfully used the CCN driver?
  29. Replies
    37
    Views
    2,818

    Osiyo, sorry to hear of your lose. You, your...

    Osiyo, sorry to hear of your lose. You, your family, and close friends are in my thoughts.
  30. Replies
    19
    Views
    1,603

    Thanks for the respnse. Can it be used to...

    Thanks for the respnse.

    Can it be used to display the supervisor history chart on the vav PX?
  31. Replies
    19
    Views
    1,603

    AX history chart on px

    I am having a brain fart or this isn't possible....been sitting here stumped for an hour!

    I have jaces with histories setup in them, sending the histories to the supervisor daily. All control...
  32. Replies
    5
    Views
    802

    Tridium AX CCN driver

    We have recently installed a Jace 6 with a CCN driver connected to just 1 19XRV chiller. Job went very well , learned all desired points. After about a week of normal operation, one morning the...
  33. Replies
    2
    Views
    392

    KitControl interval trigger and a select? Theres...

    KitControl interval trigger and a select? Theres many other way.......
  34. Also do you have the network terminated at each...

    Also do you have the network terminated at each end with terminating resistors?
  35. Is the meter/converter address unique? Do you...

    Is the meter/converter address unique? Do you have the baud rate, and parity setup correctly in the meter/converter?
  36. Replies
    6
    Views
    821

    Are these fully programmables or application...

    Are these fully programmables or application specific? If fully programmable then you will certainly need that additional tool. If asc then you should be able to perform replace, download and...
  37. Replies
    0
    Views
    375

    Single zone mini split BACnet

    I am looking for a single zone mini split heat pump that will easily communicate BACnet or a mini-split that I can put a programmable DDC controller on to control it. Specifically it needs to be a...
  38. Replies
    4
    Views
    773

    They are all serving the same space, the VAVs are...

    They are all serving the same space, the VAVs are slightly modified venom apps.

    There are no local sensor overrides.

    When should I start the RTU for recovery, unoccupied cooling etc.
    ...
  39. Replies
    4
    Views
    773

    Spyder VENOM VAVs RTU scheduling

    RTU with 15-20 vavs. I would like to use the recovery in the vav spyders, what would be the most effective way to start/stop the RTU?
  40. Replies
    10
    Views
    1,455

    Tuning policies max write time.

    Tuning policies max write time.
  41. Replies
    2
    Views
    652

    Yes. It was displaying properly with less VAVs,...

    Yes. It was displaying properly with less VAVs, but once I had added all 37 no bueno.

    Its always something........
  42. Replies
    2
    Views
    652

    Ax ReportService problem

    I have built a component grid to display points from 37 VAV controllers. I want to place the grid on a px page. The problem is when I try to view the grid table or grid label panel is kicks me out...
  43. Replies
    4
    Views
    560

    lmao....you guys are cracking me up!

    lmao....you guys are cracking me up!
  44. Let's hear it. I'll buy you a beer. God knows...

    Let's hear it. I'll buy you a beer. God knows I've drank plenty thinking about spyder problems!
  45. Replies
    2
    Views
    493

    How many IO modules on JACE 6?

    I have looked at IO16, IO34 literature and they all only mention Jace 2 IO module limits. Anybody know how many can be put on a JACE 6? I am looking for some way to control 16 AI, 27 DI, and 23...
  46. Replies
    2
    Views
    630

    BuildingLogix XD Pro

    Is anyone familiar with this device. It states that it has Niagara AX connectivity? The box has a microsoft sticker on it.....so i'm guessing that it may be a softjace? Are the licenses open to...
  47. Replies
    0
    Views
    436

    Controls tech needed - Atlanta, GA

    Small mechanical/controls company needs controls tech. Top benefits/pay. Tridium Niagara experience required, LON, BACNET, MODBUS, TRANE experience a plus.
  48. Replies
    0
    Views
    406

    Controls tech needed - Atlanta, GA

    Small mechanical/controls business needs control tech. Top benefits/pay. Tridium Niagara experience required, LON, BACNET, MODBUS, TRANE experience a plus.
  49. Replies
    0
    Views
    361

    Help Mcquay Monitor software needed

    I am trying to replace a Mcquay BACdrop panel with a Fieldserver. This thing is connected to some self contained water cooled units and looks like I have to reconfigure the comm ports on one of the...
  50. Replies
    1
    Views
    382

    The ax Andover driver is made to perform a serial...

    The ax Andover driver is made to perform a serial connection to the Andover Netcontroller or similar (read the driver guide). So yes the Andover continuum frontend could go away, but I would suggest...
Results 1 to 50 of 392
Page 1 of 8 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech365 Virtual Event