    Dirty air filter, no blower or very hot inside...

    Dirty air filter, no blower or very hot inside the house.
  2. Removed DIY Advice

    Removed DIY Advice
  3. Replies
    3
    Views
    568

    It's like a cold can of beer sitting outside, it...

    It's like a cold can of beer sitting outside, it sweats. Cheers
  4. Poke a hole in the duct, drain the water, call it...

    Poke a hole in the duct, drain the water, call it a day. Cheers
  5. A 4 ton unit will cool 2400 sqft and move 1600cfm...

    A 4 ton unit will cool 2400 sqft and move 1600cfm of air. Also your air handler is from 2008 you might have got ripped off if you bought a new system.
  6. Replies
    15
    Views
    1,481

    The contactor in the outdoor unit maybe bad and...

    The contactor in the outdoor unit maybe bad and sticking causing the unit to stay running
  7. Replies
    14
    Views
    2,085

    Leaky evap coils are famous these days

    Leaky evap coils are famous these days
  8. The outdoor TXV is stuck open, you can try...

    The outdoor TXV is stuck open, you can try putting the bulb in ice water to see if TXV closes and also putting the bulb in hot water to see if it opens. Watch your suction pressure. You need to...
  9. Replies
    13
    Views
    1,862

    At 50 degrees outside there is no load on...

    At 50 degrees outside there is no load on equipment and pressures will be off in cooling mode. The proper way to charge heat pump is to recover the refrigerant and weigh in the factory charge. But...
  10. Check the Discharge line temp outside the outdoor...

    Check the Discharge line temp outside the outdoor unit. If extremely hot like in the 200's the outdoor TXV is bad. I had a armstrong unit do the same thing. Run fine in cooling but in heat i had...
  11. Thread: York

    by Huntinwalkerstyle
    Replies
    11
    Views
    1,339

    Trane does make a good unit, for all you trane...

    Trane does make a good unit, for all you trane lovers
  12. Thread: York

    by Huntinwalkerstyle
    Replies
    11
    Views
    1,339

    York themselves don't advertise its the dealers. ...

    York themselves don't advertise its the dealers. Im a york dealer and i have to say what few problems we have with them york backs us 100% not like crappy trane. We use to be a trane dealer to but...
  13. Thread: LRA

    by Huntinwalkerstyle
    Replies
    10
    Views
    1,241

    The LRA on the plate is what that compressor is...

    The LRA on the plate is what that compressor is tested at. I have seen alot of units run past that rating but not very long.
  14. Thread: LRA

    by Huntinwalkerstyle
    Replies
    10
    Views
    1,241

    If compressor is pulling LRA then it needs to be...

    If compressor is pulling LRA then it needs to be replaced.
  15. Replies
    25
    Views
    2,556

    He's old school

    He's old school
  16. Replies
    16
    Views
    1,899

    I have seen 10 to 16 degrees at 6 inches from...

    I have seen 10 to 16 degrees at 6 inches from body.
  17. I agree over 150 ohms and replacing.

    I agree over 150 ohms and replacing.
  18. Replies
    14
    Views
    1,229

    Is it the right evap piston for that outdoor unit

    Is it the right evap piston for that outdoor unit
  19. Replies
    28
    Views
    9,353

    TXV problem

    TXV problem
  20. Thread: york

    by Huntinwalkerstyle
    Replies
    6
    Views
    797

    Sounds like its over charged

    Sounds like its over charged
  21. Replies
    27
    Views
    4,714

    Its a matter of time before it fails

    Its a matter of time before it fails
  22. Replies
    27
    Views
    4,714

    If its pulling high amps then condemn the...

    If its pulling high amps then condemn the compressor
  23. Replies
    24
    Views
    2,716

    Just experience using different hoses

    Just experience using different hoses
  24. Replies
    27
    Views
    4,714

    What is the LRA and what is the compressor rated...

    What is the LRA and what is the compressor rated at? 30 plus amps sounds high in a 5 ton system.
  25. Replies
    24
    Views
    2,716

    Yellow jacket makes ball valve end hoses, they...

    Yellow jacket makes ball valve end hoses, they are very nice. I think RE Michel sells them for $120.00
  26. Replies
    24
    Views
    2,716

    I used yellow jacket low loss hoses and had...

    I used yellow jacket low loss hoses and had trouble with the high side too. I think the low loss ends are not made for anything above 325psi. I use there ball valve ends now and no problems
  27. Replies
    5
    Views
    1,324

    Is the compressor pulling high amps on start up? ...

    Is the compressor pulling high amps on start up? Double check the wiring at the current sensing relay.
  28. Replies
    19
    Views
    3,367

    Mitsubishi makes a flush ceiling mount air...

    Mitsubishi makes a flush ceiling mount air handler unit
  29. Replies
    19
    Views
    3,367

    Maybe a window unit

    Maybe a window unit
  30. Replies
    25
    Views
    2,481

    I have seen 115 to 125 degrees at about 95...

    I have seen 115 to 125 degrees at about 95 degrees outside
  31. You add refrigerant to raise subcool and remove...

    You add refrigerant to raise subcool and remove refrigerant to lower subcool
  32. Replies
    15
    Views
    1,937

    Somebody installed this not knowing what they...

    Somebody installed this not knowing what they were doing
  33. Replies
    15
    Views
    1,937

    Jack legs installed this one

    Jack legs installed this one
  34. Replies
    19
    Views
    1,600

    Ok the compressor is bad then. It comes on but...

    Ok the compressor is bad then. It comes on but doesn't pump refrigerant. Thats called a no pumper
  35. Replies
    19
    Views
    1,600

    Also is this a heat pump, if so remove the O wire...

    Also is this a heat pump, if so remove the O wire and see what the pressures do maybe the reversing valve is not all the way in cool mode
  36. Replies
    19
    Views
    1,600

    If the compressor started 7 min after the...

    If the compressor started 7 min after the condenser fan then the compressor is at fault. What is the amp draw of the compressor running? Also does it make any noises before it starts, if it does...
  37. Replies
    25
    Views
    2,672

    Yellow jackets full digital

    Yellow jackets full digital
  38. Replies
    19
    Views
    1,600

    Take the bulb loose from the suction line and...

    Take the bulb loose from the suction line and stick it in hot water. This will open the TXV wide open and your pressure should come up.
  39. No insulation in the house is a BIG PROBLEM....

    No insulation in the house is a BIG PROBLEM.
    Whats the temp outside? If you have 75 degree
    return and its 95 degrees outside then i will
    say the unit is doing all it can
  40. Replies
    19
    Views
    1,600

    Please post what your findings were

    Please post what your findings were
  41. Replies
    19
    Views
    1,600

    Does the unit have a TXV at the evap coil. If it...

    Does the unit have a TXV at the evap coil. If it does try
    Putting the bulb in hot water and check your pressures.