  1. make sense!

    make sense!
  2. Replies
    8
    Views
    850

    Why they cut it?it realy look like same size pipe...

    Why they cut it?it realy look like same size pipe to me,just have to make 90 turn to angel it need ?
  3. Replies
    8
    Views
    850

    Wow!somebody must point a gun to they head make...

    Wow!somebody must point a gun to they head make them rush to finish that job,Ray Charles can do better then that!as far as flu air flow concern,somebody have better knowledge can help u with that!i...
  4. Replies
    17
    Views
    1,064

    Ur second tech sounds like he got some...

    Ur second tech sounds like he got some knowledge,but he make the wrong choice mess around other things,he should replace txv and drier first and check liquid line restriction with pressure u...
  5. why manufactury get cheaper copper product save...

    why manufactury get cheaper copper product save tons of money,but our equipment price still keep going up each year???
  6. when u measure the current must measure one to...

    when u measure the current must measure one to common another to terminal u want to check to get voltage reading !
  7. Replies
    159
    Views
    8,202

    Sorry didnt read the long post,condenser can be...

    Sorry didnt read the long post,condenser can be 13 seer with variable speed air handler make it 14 seer!hope i am correct!
  8. Replies
    17
    Views
    942

    extent lineset and voltage wires,done!

    extent lineset and voltage wires,done!
  9. Thread: Makes it rough

    by pony
    Replies
    5
    Views
    418

    It happen to most peoples,supply house worker can...

    It happen to most peoples,supply house worker can make mistake also,and i know they mistake allways cost us money and labor,not blaming them make mistake,but blaming them knowing they made a mistake...
  10. Replies
    15
    Views
    2,108

    More freon!

    More freon!
  11. Thread: X13 motors

    by pony
    Replies
    23
    Views
    10,799

    What about lennox CBX27 x13 motor,heard anything...

    What about lennox CBX27 x13 motor,heard anything bad about it?
  12. Old evap coil with r410a pressure,i rather go...

    Old evap coil with r410a pressure,i rather go with lower pressure r22 unit!
  13. Like to try it one day in tight spot!

    Like to try it one day in tight spot!
  14. Replies
    19
    Views
    1,596

    Dont worry!u will get better !

    Dont worry!u will get better !
  15. Replies
    10
    Views
    884

    I usually tell then it take little time to...

    I usually tell then it take little time to circlaire the hot air out before they even open they mouth after i fix it!Lol!i would said about 99% of the customer can feel the cold air cause they have...
  16. Replies
    20
    Views
    826

    if u have proper charge SC should be around...

    if u have proper charge SC should be around 10-12F,do u?
  17. Replies
    20
    Views
    826

    what is SC?

    what is SC?
  18. Thread: what's going on?

    by pony
    Replies
    9
    Views
    662

    sounds like restriction!

    sounds like restriction!
  19. Replies
    159
    Views
    8,202

    Why discontinue dry R22?they are few r22...

    Why discontinue dry R22?they are few r22 replacement refrigerant ozone friendly can put in R22 unit?if goverment concern about seer rating,txv or X13 motor will increase seer rating maybe even 1/2...
  20. Replies
    56
    Views
    2,397

    Mr Udarrell,honor be on the same post with u,read...

    Mr Udarrell,honor be on the same post with u,read a lots of ur online hvac trouble shooting information back when i first start this line of work,thank u!
  21. Replies
    56
    Views
    2,397

    How do u get refrigerant out before u change coil...

    How do u get refrigerant out before u change coil and condenser?if u change wrong indoor coil,u will find out real quick with refrigerant all over ur face when u cut the cooper line indoor coil?so it...
  22. Thread: "A" coil sideways

    by pony
    Replies
    14
    Views
    697

    up and down flow coil ok sideway if u have...

    up and down flow coil ok sideway if u have to,horizontal coil dont think have drain pan on side,so have to install drain pan on the bottom!
  23. Replies
    29
    Views
    1,359

    bad board will be my first guess!

    bad board will be my first guess!
  24. Thread: Bryant txv

    by pony
    Replies
    188
    Views
    16,479

    Not big fan of txv valve just like ECM motor,to...

    Not big fan of txv valve just like ECM motor,to many fail for different reason,if u install by the book,purge nitro while braze,dons't mean txv not goona mulfuction !cost more money for customer and ...
  25. If i am not mistaken,u r talking about use...

    If i am not mistaken,u r talking about use manifold gauge bring refrigerant from highside to low side cause ur txv was bad clogged?it is good idea ,but first verify the txv is clogged,hook u gauge...
  26. Replies
    17
    Views
    1,212

    put some oil on it,put the wrench on and tap it...

    put some oil on it,put the wrench on and tap it both direction ,
  27. Thread: No Superheat

    by pony
    Replies
    57
    Views
    4,288

    Everytime i runinto low SH and low suction line...

    Everytime i runinto low SH and low suction line temp i will first check either over feeding evap coil or low air flow!
  28. Thread: is everything ok

    by pony
    Replies
    8
    Views
    327

    28F DT kind of high?speed tap on high?condenser...

    28F DT kind of high?speed tap on high?condenser restriction maybe?
  29. I hate to said it,but most regulation and laws...

    I hate to said it,but most regulation and laws have in this country realy just BS to me!just my 2 cent,u will think goverment shouldnt let this kind of refrigerant on the market,but they did!!
  30. Replies
    29
    Views
    1,463

    X2

    X2
  31. Replies
    15
    Views
    861

    I use testo 550 temp clamp porbe today,when i...

    I use testo 550 temp clamp porbe today,when i clamp on 3 or9 oclock temp 8 degree higher then clamp on 6 oclock!i believe copper near ground temp is lower,i maybe wrong!there are different temp on...
  32. Replies
    40
    Views
    2,106

    Frost suction line,low SC and SH=low...

    Frost suction line,low SC and SH=low airflow,frost suction line,high SH with low SC=under charge.it apply most of case,not every case.
  33. Replies
    40
    Views
    2,106

    Esp check will tell u ur airflow correct or...

    Esp check will tell u ur airflow correct or not,most of time i will check the coil condition first and use low restriction air filter if is older system,have few call unit have low SC and SH with low...
  34. Replies
    145
    Views
    8,965

    didnt know those ECM motor save customer money or...

    didnt know those ECM motor save customer money or not?lol!
  35. Thread: pulling a vacuum

    by pony
    Replies
    161
    Views
    56,062

    I have system past pressure test but didnt pass...

    I have system past pressure test but didnt pass vacuum test,and sure not find a very tiny leak!micron gauge is a must have tools!
  36. Replies
    9
    Views
    341

    2 tons unit change from fixed metering to txv...

    2 tons unit change from fixed metering to txv outdoor condenser,how much money do ur think it will save u a month?10 dollars,20 dollars or 50 dollars?just like to know it is worth do it or not!and...
  37. When u ad freon into system when u suspect low...

    When u ad freon into system when u suspect low charge,u have to use good temp device!most of time u have to wait for mins or two see suction line temp drop or not,i use testo 550 gauge it will tell...
  38. Replies
    10
    Views
    489

    may have a leak!did u do pressure drop test and...

    may have a leak!did u do pressure drop test and vacuum down below 1000 microns and stay?
  39. Replies
    12
    Views
    708

    Should print on top of txv ' internal check...

    Should print on top of txv ' internal check valve',if not,maybe is straight ac txv,and how old is the unit,it can't be working for all these time?
  40. Replies
    21
    Views
    1,557

    Hope i never runinto situation u have,freon out...

    Hope i never runinto situation u have,freon out in weeks,yes there is leak some where,pressure test didnt drop in few days,i will first check the hoses and gauges make sure nitor in the system!some...
  41. Replies
    11
    Views
    843

    High voltage short?new unit?better check all his...

    High voltage short?new unit?better check all his wiring! it didn't trip the breaker?
  42. Replies
    8
    Views
    758

    U didnt charge customer dianostic fee did u?haha!

    U didnt charge customer dianostic fee did u?haha!
  43. Replies
    19
    Views
    1,548

    Suction line 56F indoor air supply 68F(assume is...

    Suction line 56F indoor air supply 68F(assume is supply air),u lost u temperture some where,i agree the heat strips possible running!
  44. Replies
    39
    Views
    2,701

    suction line iceing up,no leak,clean coil,no...

    suction line iceing up,no leak,clean coil,no restriction,correct charge pure r22 in system,so what is the problems cause it iceing up?bad metering device maybe?
  45. Thread: heat pump

    by pony
    Replies
    16
    Views
    933

    Dianostic bad reversing valve ,dont matter in...

    Dianostic bad reversing valve ,dont matter in cooling or heating mode,suction should be within 3F DT,discharge should be within 3F DT at reversing valve,if they look ok,then u need to check the ...
  46. Thread: Testo 550 problem

    by pony
    Replies
    26
    Views
    5,096

    to doug at testo,i have this testo 550 for 2...

    to doug at testo,i have this testo 550 for 2 years,and already send it back twice for repair,and now the screen cover with all the information and it wont turn off except take battery out,i am not...
  47. Replies
    170
    Views
    18,026

    I dont know ur experiences with testo 550,i will...

    I dont know ur experiences with testo 550,i will not buy another one,it made for few time use only,feel like it made in China!!!only for one time use!!!
  48. Replies
    16
    Views
    9,617

    ok,here is thing i like to get soem input,believe...

    ok,here is thing i like to get soem input,believe most of ur have same experiences,when u adjust freon level for heat pump in heating mode,some ad freon will rasie vapor line temp and some remove...
  49. Thread: HELP heat pump

    by pony
    Replies
    18
    Views
    1,338

    sorry,i believe i shouldnt give advice on this...

    sorry,i believe i shouldnt give advice on this site!
  50. Replies
    68
    Views
    6,867

    will non condensible cause hunting subcooling?

    will non condensible cause hunting subcooling?