  1. Replies
    5
    Views
    1,636

    I only have a couple of modules at the moment so...

    I only have a couple of modules at the moment so I quickly replaced the old keys for new and changed the address' to suit and everything seems to be working ok.

    Many Thanks

    Gareth
  2. Replies
    5
    Views
    1,636

    Siemens MBC Module Addressing

    I think you have cracked it. Would I be correct in saying that the old keys were white lettering on a blue back ground and the new keys are black lettering on a blue background? I see that I have a...
  3. Replies
    5
    Views
    1,636

    Siemens MBC Module Addressing

    I would appreciate some help on the addressing of MBC Modules. I have a single MBC, a few modules and two DPUs. The system is not connected to anything at the moment so it can be switched on /off...
  4. Replies
    4
    Views
    1,874

    Siemens Apogee Insight DPU

    Thanks

    I've am now able to bring the DPU's online and program the I/O.

    Many thanks once again. Just have to get up to speed with PPCL now.

    Gareth
  5. Replies
    4
    Views
    1,874

    Siemens Apogee Insight DPU

    Hi there Dingman

    I've since found that Lan (Trunk) 1 on the Open processor module is suspect as I connected a second DPU to Lan (Trunk) 2 and then used the DPU/MPU search facility on the system...
  6. Replies
    4
    Views
    1,874

    Siemens Apogee Insight DPU

    I want to connect a recovered DPU (12in / 12 out) to an existing MBC. I am still running NT4 +SP6 and Insight 3.2 and the size of the system does not justify upgrading to the current version of...
  7. Replies
    15
    Views
    16,182

    Induction Units

    Hi

    I have attached a sheet showing the basic operation of the unit. If you want more contact me direct and I can mail more sheets to you.

    Gareth
  8. Replies
    15
    Views
    16,182

    Induction system HVAC

    We have a system here in a building built in the 70's which worked very well, it would keep an office on the perimeter of the building i.e. 50% glass in the outside wall and OAT up to 35deg C to...
  9. Replies
    6
    Views
    2,783

    Siemens TEC Configuration

    Hi there

    Siemens here in RSA is the Siemens that deals with the Industrial S5/S7 etc PLCs.

    The company that deals with the Insight etc here, is really only an import agency dealing with a...
  10. Replies
    6
    Views
    2,783

    Siemens Apogee TEC configuration

    Hi there

    Tried as you suggested and it works 100%. I don't remember being able to do that when I was actually involved a few years ago with the Insight system.

    Many thanks

    Gareth
  11. Replies
    6
    Views
    2,783

    Siemens Apogee TEC configuration

    Hi there

    Done, it's surprising what one forgets when you are away for a couple of years.

    Many thanks

    Gareth
  12. Replies
    6
    Views
    2,783

    Siemens Apogee TEC configuration

    I have been away from HVAC controls for a number of years (retired) but have just been given some Siemens Insight equipment to play with tp keep the gray matter working.
    There is one MBC with Power...