  1. Replies
    29
    Views
    4,963

    Ducks are not as long-lived as geese. The average...

    Ducks are not as long-lived as geese. The average life span of a domestic duck is 10 years or less.

    As a general rule, the larger breeds of duck have the shortest life spans. Seldom do they live...
  2. Replies
    33
    Views
    3,397

    lol

    lol
  3. Replies
    33
    Views
    3,397

    wgtvsvsdfv

    Using the existing lineset is fine if its meets size standards. A nitrogen purge followed an R11 flush is recommended for r22 to 410a conversion. Installing a liquid line drier and pulling a vacuum...
  4. Replies
    48
    Views
    3,301

    this is a Singer

    this is a Singer
  5. Replies
    24
    Views
    2,428

    I had one of these this summer!

    I had a Trane HP fan go in reverse this summer. I simply changed the cap and it changed the rotation. I'm not sure why, but it worked.
    A Happy customer is a happy tech.
  6. I see this all the time with Trane evap coils. ...

    I see this all the time with Trane evap coils.

    Like they say, "You can't stop a Trane" until you install it.
  7. I like to touch it real quick...it beats coffee.

    I like to touch it real quick...it beats coffee.
  8. thanks dandy..

    this is going on a Trane WCD090C300BC...I haven't been on the roof today, but I do know there not a scematic on the inside panel anymore.

    I figured I could use the terminal board numbers because...
  9. BAYSENS009B, Need help changing to BAYSENS019

    Hello again folks!

    I bought the BAYSENS019 dig. pro. zone sensor. I am taking out the BAYSENS009b manual sensor. I am having trouble re-wiring the new zone, this being my first time. I think I...
  10. Replies
    5
    Views
    1,459

    Thanks to all

    I will most likely look for the the programmable baysen019 vs the interface board. Thanks for everyone's help! :)
  11. Replies
    5
    Views
    1,459

    BAYSENS009B stat...

    BAYSENS009B TSTAT needs to be repalced...controls a Trane RTU WCD090C300BC

    I need to replace this particular dc volt stat. I am looking for a digital programmable with lock-out feature. Trane has...
  12. PROBLEM SOLVED!!!!!!! Wrangler...you were...

    PROBLEM SOLVED!!!!!!!

    Wrangler...you were right, it might be new, 'but was it the right contactor.' I went and double checked to find out that a 110-120 volt coil contactor was put in a 24volt...
  13. Trane TWA048C300A2 contactor not engaging all the way

    Heat Pump Trane TWA048C300A2

    Air Handler Trane TWE048C140B3

    When calling for cooling, I am reading 24-25 volts at condenser contactor. That should be enough to energize the contacts competely....
  14. Replies
    1
    Views
    1,257

    Trane TTR030C100A3?

    Trane ttr030c100a3
    I've been given this model number without looking at the actual unit. I'll be looking for a replacement unit (system), can anyone tell me if this is a heat pump and if the...
  15. Replies
    2
    Views
    707

    Carrier Heat Pump Pecker Blown

    Carrier 38ycc036340-
    Went on a call this weekend where I found an oil puddle next to the compressor. This obviously tells me of a leak. My guages showed the system flat on refrigerant, so I put...
  16. Replies
    6
    Views
    896

    Airworx was right...

    It was the setpoint on the stat, but the stat is also not calibrated right. Thanks for all the help guys!
  17. Replies
    17
    Views
    2,756

    simply a...

    I'm sure this is simply a disconnected return duct (if there is one ) or he is just sucking the air from the inside of the walls because it wasnt finished in the return box, which is normal for track...
  18. Replies
    6
    Views
    896

    I did take temps, but I didnt record. Ill take...

    I did take temps, but I didnt record. Ill take some tomorrow of enter/leave and let u guys know. Thanks Mr Chill
  19. Replies
    6
    Views
    896

    Carrier 30HK040-630 Chiller

    I Carrier 30HK040-630 Chiller

    This chiller is tripping on 'low water temperature cutout.' Ambient temp being about 75-80, control stat at 48, freeze stat at 36. I'm running comp 2 in lead with...
  20. Anybody ever worked on Lawler cascade systems?

    Lawler cascade systems
  21. Replies
    15
    Views
    4,563

    you need to buy a simple duct calculator. You can...

    you need to buy a simple duct calculator. You can find them at the parts houses sometimes, For Free!!!
  22. HELP!Model 203C Lawler Pour Pt Bath

    203C Lawler Pour Point Bath 414B & R22 (cascade bath freezer)
    I'm currently working on a Lawler Pour Point Bath. I've replaced a condensing coil and did some basic maitenance. This bath runs 2...
  23. 3m filters bad?

    Never heard that 3m filters restrict air flow right off the bat, true?
  24. Replies
    6
    Views
    650

    failed to mention...

    This install is actually a favor for my father-in-law. Im not misleading him, he knows about the wtty & seer issue. even if this was one of my customers, I would push for them to change the inside...
  25. Replies
    6
    Views
    650

    hmmm..

    valid point taken...

    I understand the seer effect. Why not 4 tons of cooling? Ive done this install in the past. Seems to work okay. And yes, the cond. mfgr doesn't know about the mismatch for the...