06-14-2011, 12:25 PM
Thread: whoomping sound from chw ahu....please help
by m8j4c- Replies
- 16
- Views
- 1,168
Any fire dampers closed that aren't supposed to...
Any fire dampers closed that aren't supposed to be?
-
06-14-2011, 01:23 AM
Thread: whoomping sound from chw ahu....please help
by m8j4c- Replies
- 16
- Views
- 1,168
Did the noise stop when you opened the door to...
Did the noise stop when you opened the door to the fan belt section?
-
05-31-2011, 09:14 PM
Thread: time on break
by m8j4c- Replies
- 5
- Views
- 687
You can probably program a cooling minimum run...
You can probably program a cooling minimum run time and/or compressor cycles per hour to control that in your t-stat.
-
05-31-2011, 08:54 PM
Thread: 4 way reversing valve question
by m8j4c- Replies
- 16
- Views
- 677
If you're changing out the valve I would sawzall...
If you're changing out the valve I would sawzall the top 3 lines at the bad reversing valve body so that you have the female side of the reversing valve connections still there then in unsweat the...
-
05-26-2011, 12:53 PM
Thread: 410 a refrigerant
by m8j4c- Replies
- 6
- Views
- 417
Of course you can top it off. Why would you have...
Of course you can top it off. Why would you have to recover it all?
-
05-26-2011, 11:50 AM
Thread: txv setting and assembly
by m8j4c- Replies
- 27
- Views
- 1,176
Why don't you just measure your actual superheat...
Why don't you just measure your actual superheat and adjust it to dial it in?
-
Chopper time!
Chopper time!
-
05-26-2011, 11:41 AM
- Replies
- 1
- Views
- 266
Depends who you are doing your apprenticeship...
Depends who you are doing your apprenticeship with. I know in my union guys who had experience could take a placement test and if you tested really well they would knock off a year or 2 off your...
-
05-25-2011, 10:44 PM
- Replies
- 9
- Views
- 2,544
Is there pressure taps on both sides of the...
Is there pressure taps on both sides of the condensor loop to check pressure drop? I cant remember with crac units... If there is theres usually some reference chart to see if your flow through the...
-
05-25-2011, 10:20 PM
Thread: Air Conditioning Condenser
by m8j4c- Replies
- 6
- Views
- 404
Not to mention, a compressor that old could very...
Not to mention, a compressor that old could very well have some damage to the valves or pistons which isnt allowing it to "pump" as effectively. Which would be why it runs all day and only works...
-
05-25-2011, 12:09 AM
- Replies
- 12
- Views
- 1,694
Referteacher got it. Just take your time and...
Referteacher got it. Just take your time and shake the foam down.
-
05-25-2011, 12:07 AM
Thread: Data room air conditioner
by m8j4c- Replies
- 20
- Views
- 1,553
Fan cycle controller. Or whatever you are more...
Fan cycle controller. Or whatever you are more comfortable with.
-
05-25-2011, 12:03 AM
Thread: carrier 19XL high bearing temp
by m8j4c- Replies
- 5
- Views
- 674
Check the Oil cooler.. Maybe a failing bearing.
Check the Oil cooler.. Maybe a failing bearing.
-
Yeah, find the nearest meth dealer and make a...
Yeah, find the nearest meth dealer and make a fortune off of him! Its funny cause its true...
-
Go to a local refrigeration supply parts house....
Go to a local refrigeration supply parts house. They usually offer the tests. Comes with a book to study, usually around $60-$75.
-
05-24-2011, 11:00 PM
Thread: Southern Missouri Techs...
by m8j4c- Replies
- 10
- Views
- 745
yeah that was crazy.. Still trying to get a hold...
yeah that was crazy.. Still trying to get a hold of some cousins who live there myself...
-
05-24-2011, 10:52 PM
Thread: Green slime?
by m8j4c- Replies
- 15
- Views
- 885
This is crazy.. I havent seen this yet and...
This is crazy.. I havent seen this yet and thought it only happens on chillers with a leak in the evap where the water pressure was somewhat high.
-
05-24-2011, 10:37 PM
Thread: "ventilation fan"
by m8j4c- Replies
- 5
- Views
- 368
Stick with the whole house fan idea using your...
Stick with the whole house fan idea using your access hole. Play around with only opening a few room windows and your main issue with it not being able to move enough air maybe due to you not having...
-
05-21-2011, 06:57 PM
- Replies
- 11
- Views
- 1,292
Diceman, Why would a coil keep leaking if it has...
Diceman, Why would a coil keep leaking if it has already been fixed?
-
05-14-2011, 02:49 AM
Thread: Capacitor tester
by m8j4c- Replies
- 9
- Views
- 769
Any cheap digital meter that also reads...
Any cheap digital meter that also reads microfarads will work. If its something you are gonna use alot, dont go cheap.
-
05-14-2011, 02:47 AM
- Replies
- 8
- Views
- 699
Try to get them the comissioning report if you...
Try to get them the comissioning report if you can, thats all you can do. I used to work for Carrier and did a lot of warranty work. If you bug them enough they will take care of it for you. Beleive...
-
05-14-2011, 02:37 AM
Thread: Getting started
by m8j4c- Replies
- 4
- Views
- 373
Somebody is breaking you in pretty quickly. Not...
Somebody is breaking you in pretty quickly. Not bad.
-
05-14-2011, 02:34 AM
Thread: furnace problems
by m8j4c- Replies
- 2
- Views
- 314
Lets leave diagnostics to an on site tech, please...
Lets leave diagnostics to an on site tech, please read site rules, thank you.
-
03-03-2008, 05:11 PM
Thread: Kansas City Area
by m8j4c- Replies
- 10
- Views
- 616
Steward, what do you mean "eq. in town"???
Steward, what do you mean "eq. in town"???
-
03-03-2008, 05:08 PM
Thread: Kansas City Area
by m8j4c- Replies
- 10
- Views
- 616
Freonrick, Who do you work for now? What was it...
Freonrick, Who do you work for now?
What was it about Carrier's management that made you leave?
Results 1 to 25 of 32