  1. I have had this same problem with a trane furnace...

    I have had this same problem with a trane furnace connected to a honda generater. on the generator if you measure with your meter from neutral to ground you will get 60 volts. trane circuit boards...
  2. Thread: Nest?

    by furnacemaninc
    Replies
    17
    Views
    1,200

    Honeywell knows HVAC Sent from my iPad...

    Honeywell knows HVAC


    Sent from my iPad using Tapatalk
  3. Replies
    11
    Views
    2,642

    I prefer spray glue, it stops them instantly and...

    I prefer spray glue, it stops them instantly and I get to pretend I'm spider man


    Sent from my iPad using Tapatalk
  4. Replies
    3
    Views
    341

    Nice burn :cheers:

    Nice burn :cheers:
  5. Replies
    3
    Views
    341

    User name

    Is there a way to change my user name?
  6. Replies
    9
    Views
    816

    Thanks for all the help, I'll give an update...

    Thanks for all the help, I'll give an update after the repair is completed
  7. Replies
    9
    Views
    816

    The check valve is piped in parallel with the...

    The check valve is piped in parallel with the outdoor coil txv, the indoor coil uses a fixed orfice, suction dryer was piped in between the compressor and the reversing valve, unit m# wsc120a4roa1
  8. Replies
    9
    Views
    816

    Heat pump pumping down

    I have a 10ton trane r22 rooftop heat pump package unit that has two five ton comps splitting the capacity. I replaced a burnt out compressor yesterday, new filter dryer added suction dryer, replaced...
  9. Replies
    4
    Views
    530

    When you replaced the txv did you change out the...

    When you replaced the txv did you change out the screen right before the valve?


    Sent from my iPad using Tapatalk
  10. 45 for copper 37 for stainless

    45 for copper
    37 for stainless
  11. Replies
    21
    Views
    1,973

    I always thought the 5' of flex was for t bar...

    I always thought the 5' of flex was for t bar register connection
  12. Replies
    6
    Views
    719

    Take care of that air flow problem, adjust the...

    Take care of that air flow problem, adjust the txv then dial in the charge.
  13. Replies
    9
    Views
    1,043

    Sounds just like one hour

    Sounds just like one hour
  14. Replies
    12
    Views
    3,290

    Is this unit direct or belt drive, if belt drive,...

    Is this unit direct or belt drive, if belt drive, follow low voltage wires over the top of the blower and check for chaffing. I have often seen the wires shorting on the 5/16 screw heads. Is the...
  15. Replies
    34
    Views
    6,377

    The Goodman guy is at it again…

    The Goodman guy is at it again…
  16. Replies
    8
    Views
    1,602

    if the transformer is set at 230 and power is...

    if the transformer is set at 230 and power is 208, you might need to change the setup
  17. Yes I tried closing one of the service valve,but...

    Yes I tried closing one of the service valve,but no luck, what if I have too much oilin the compressor? I was thinking about changing the comp oil at the same time as the valve.
  18. The valve would not switch out of the heating...

    The valve would not switch out of the heating position, when the coil was energized i could hear the pilot valve click, i
    I also confirmed the refrigerant charge was ok. Both valves and refrigerant...
  19. reversing valve trouble, heeeeeeeeeeeeeeeeeeelp!

    I have beeb working on a new EMI 3x multi heat pump. I replaced the reversing valve and operation to the unit was restored, the following month the same thing happens, once again the the valve was...
  20. Replies
    30
    Views
    5,332

    Get something with side clips instead of...

    Get something with side clips instead of Velcro,they will last much longer, gel is best, flat caps are good so they stay on your knees.
  21. Replies
    15
    Views
    1,752

    I had a hot tub pump do that and it ended up...

    I had a hot tub pump do that and it ended up being the outlet
  22. Replies
    36
    Views
    9,386

    DONT USE IT! I used it to try to help out an old...

    DONT USE IT! I used it to try to help out an old time custumer and it ended up seizing the compressor 3 months later
  23. Replies
    23
    Views
    4,911

    Then we clean the coil and watch the top of the...

    Then we clean the coil and watch the top of the compressor pop from all the freezone that was put in.
  24. Replies
    16
    Views
    3,814

    they really must have felt like welding something?

    they really must have felt like welding something?
  25. Replies
    9
    Views
    3,483

    thats needs to be in the hall of fame, those last...

    thats needs to be in the hall of fame, those last for ever! watch out for the A stuff..
  26. Replies
    23
    Views
    4,911

    did it ever have a filter?

    did it ever have a filter?
  27. Replies
    15
    Views
    2,759

    Those red,white,blue ones from johnstone don't...

    Those red,white,blue ones from johnstone don't last very long, i went back to the oem bdp burner to prevent call backs
  28. Replies
    36
    Views
    3,884

    I had this same problem on a pg8 a couple years...

    I had this same problem on a pg8 a couple years ago, i ended up moving the HSI a little closer at a slight angle to the burner and it started lighting perfectly. To reason with it i figured vibration...
  29. Replies
    22
    Views
    3,196

    i always see these things covered in flower pots

    i always see these things covered in flower pots
  30. Replies
    7
    Views
    1,835

    this is what happens when the owner decides to...

    this is what happens when the owner decides to have his friend do the maintenance to save money but they loss in the end every time.:beat:
  31. Replies
    32
    Views
    5,034

    restarants are always the worst

    wow! did you see mad max up there?
  32. variable speed

    variable speed means the the motor ramps to maintain a set cfm, so if your filters dirty, register closed , ducts a little to small, the vs motor will speed up to a point of proper air flow across...
  33. Replies
    141
    Views
    20,221

    smwia 104 north california

    smwia 104 north california
  34. Replies
    4
    Views
    1,585

    check if the O terminal overrides the lock out...

    check if the O terminal overrides the lock out with a relay?
  35. Replies
    1
    Views
    496

    nate question

    for what reason does a heat pump have a larger outdoor coil than a air conditioner? my teacher was telling me it was to maximize pressure drop, i argued that it was to minimize pressure drop. what...
  36. Replies
    11
    Views
    932

    you will notice the blower volume change more in...

    you will notice the blower volume change more in the of cycle, if you have an xl16i and your equipment is on the large side, you might want to try setting your thermostat up so it cycles the y/lo /...
  37. Replies
    5
    Views
    671

    electric leak detectors

    i'm in the market for a electronic leak detector, does anyone know the oz per year decection a decent detector should operate at?
  38. Replies
    3
    Views
    832

    thank you,that sounds like it will work good.

    thank you,that sounds like it will work good.
  39. Replies
    3
    Views
    832

    stumped on a trane voyager

    i am working on a trane voyager that has a gas smell being emited around the forced combustion blower, the blower pulls -.15 on the gas valve and -.5 at the combustion air ports. the smell gets...
  40. Replies
    14
    Views
    1,250

    if you call for a 2nd service, ask for a...

    if you call for a 2nd service, ask for a different tech. it sounds like you might have had a parts changer out. proper diagnostic is very important
  41. Replies
    11
    Views
    2,746

    expansion tanks can save you a lot of trouble...

    expansion tanks can save you a lot of trouble down the road
  42. Replies
    2
    Views
    492

    trane furnaces and propane

    out of any furnace i work on trane furnaces that have been converted to LP
    allways get rusted burner flame crossover. anyone have any ideas on how to prevent this? by the way gas pressure is...
  43. Replies
    3
    Views
    963

    i am trying to find the tonage in the m#

    i am trying to find the tonage in the m#
  44. Replies
    3
    Views
    963

    carrier model#

    i have a carrier m#48dp014, does anyone have a model # conversion chart, i had one and lost it in company transition. thanks
  45. Replies
    16
    Views
    2,236

    if you return is to loud from being to short....

    if you return is to loud from being to short. have a company line you return can with acustical insulation, it will reduce the noise by at least 30%.it only takes about a hour or two of labor and the...
  46. the asx14 is a great unit for your buck. i...

    the asx14 is a great unit for your buck. i installed one two weeks ago. nice quiet compressor.
  47. Replies
    19
    Views
    2,722

    could be a bad txv or maybe the wrong txv for the...

    could be a bad txv or maybe the wrong txv for the r-type, if you end up replacing the txv replace the filter\dryer while you have it pumped down just in case, dryers are cheap.
  48. Replies
    1
    Views
    919

    target superheat

    so on a new a/c condensor the superheat specs are available, but how do i find "target superheat"on a unit with no specs? i just purchesed a sycromiter. any feedback would be great.