  1. Bovine excrement. The capacity of a given system...

    Bovine excrement. The capacity of a given system is based on the mass flow of the refrigerant being condensed and evaporated. Mass flow is controlled by the displacement of the compressor, which is...
  2. Replies
    12
    Views
    632

    The number one problem with DIY on here IMNSHO is...

    The number one problem with DIY on here IMNSHO is that we can't verify your credentials/knowledge on a case-by-case basis, and worse we can't verify the credentials of someone who does a search and...
  3. Replies
    35
    Views
    1,298

    It back feeds because of how multi-speed PSC and...

    It back feeds because of how multi-speed PSC and shaded pole blower/fan/centrifugal pump motors work, they have an auto-transformer integrated into the run windings and intentionally under-volt...
  4. My point was that if the inverter is starting to...

    My point was that if the inverter is starting to trip off then either A. your DC wiring is too thin or B. you are over-discharging the battery causing its internal resistance to rise.

    If it is B...
  5. The inverter's low battery cutoff is working as...

    The inverter's low battery cutoff is working as designed. You really don't want to draw a true deep cycle lead-acid battery (read medical AGM or gel or golf car flooded) down below 50% SOC, and for a...
  6. Replies
    7
    Views
    402

    The only way I would use them is with isolation,...

    The only way I would use them is with isolation, IE condensing unit outside with a hydronic loop linking it to the house or building. The pressure relief valve would be outside too in case a...
  7. Replies
    5
    Views
    372

    The problem with that site is that it uses a...

    The problem with that site is that it uses a constant voltage source and dropping resistors. LEDs are current driven devices and their voltage drops as they heat up. If this will be used where you...
  8. Yep. My parents showed me this video. A short...

    Yep. My parents showed me this video. A short explanation on why 12000 BTU/hr is called 1 ton of cooling cleared that up really quickly.

    BTW I hate faux science videos on YouTube if you can't...
  9. It sounds like they are labeled as common on the...

    It sounds like they are labeled as common on the dual run cap not common of the motor itself. IE "common" goes to capacitor common and "cap" goes to capacitor fan.

    Sent from my SCH-R530U using...
  10. Replies
    194
    Views
    19,695

    All we can do is report the videos that in some...

    All we can do is report the videos that in some way violate YouTube's TOS, correcting the uploader via the comments won't work for long because they can censor us by deleting such comments or even...
  11. Replies
    64
    Views
    9,575

    It's stumped me. Failed 3uf 370v from an early...

    It's stumped me. Failed 3uf 370v from an early 80s Emerson single speed ceiling fan, top bulged hence terminals disconnected. No PCBs so I uncrimped the can, drained the oil, and unrolled and...
  12. Since it's resurrected anyway, has anyone tried...

    Since it's resurrected anyway, has anyone tried using the ribbon burner from an old furnace, seems like it would cover a much wider swath, but then I have never used the fire method personally.
    ...
  13. Replies
    6
    Views
    384

    The condensing coil is all about rejecting heat...

    The condensing coil is all about rejecting heat from vapor at the dew point as rapidly as possible. If the coil is dirty, the discharge superheat is too high so lots of the vapor is above its dew...
  14. The residential AOP section reminds me of...

    this video.


    https://www.youtube.com/watch?v=hFFJk1-XCkk
    No matter how many times we say no DIY they still ask. Just like the trucks in that video. :gah:
  15. Looks like an LED edge lit LCD where not all of...

    Looks like an LED edge lit LCD where not all of the LEDs are working. The LEDs are connected in series strings and each string is individually current regulated, if something goes wrong the IC that...
  16. Replies
    33
    Views
    2,028

    AFAICT if the board says that it will lock out if...

    AFAICT if the board says that it will lock out if hot and neutral are reversed then it is getting the flame rod voltage from the AC line, IE with them swapped there is no voltage rod-ground which...
  17. Replies
    10
    Views
    1,810

    What was up with the audio in that clip, some of...

    What was up with the audio in that clip, some of it was only on the left channel, some only on the right channel, none on both.
  18. Well, I just R&Red the HSI on my parent's York...

    Well, I just R&Red the HSI on my parent's York downflow (P3DHB12N07501A) in the house they just bought, looks just like the one in this post except upside down, and while I was in there I cleaned the...
  19. Replies
    35
    Views
    5,920

    #12, the evaporator is below freezing and making...

    #12, the evaporator is below freezing and making frost/ice, high side is a little too high, get the tequila and margarita mix ready, it's going to be a good day for someone. :cheers: (I don't drink)
  20. Replies
    44
    Views
    4,714

    OK I'll try, suction side leak lost all the...

    OK I'll try, suction side leak lost all the refrigerant, vacuum on low side on compressor startup sucked in air, non condensable air in high side drove head pressure sky high, boom.

    I wouldn't...
  21. The best part of that is the VVS section of...

    The best part of that is the VVS section of driving the stake into the ground.


    https://www.youtube.com/watch?v=Bt9zSfinwFA
  22. Replies
    65
    Views
    7,896

    A couple of things to clear up about the portable...

    A couple of things to clear up about the portable ventless heater:

    It does not have an O2 sensor, it just has a calibrated torch flame on the pilot burner that barely touches the thermocouple tip,...
  23. Only a 750 millivolt gas valve, not like you need...

    Only a 750 millivolt gas valve, not like you need it or anything. :gah:
  24. A couple thoughts, PCs aren't nearly as sensitive...

    A couple thoughts, PCs aren't nearly as sensitive to bad power as many think, the first thing most non or passive power factor corrected switched mode power supplies do with the power is run it...
  25. Replies
    14
    Views
    3,498

    Not on something with in-shot burners, 2 stage...

    Not on something with in-shot burners, 2 stage and variable furnaces slow down the inducer to match the lower gas flow. On a natural draft furnace underfiring would just cause heat exchanger to run...