    I have not found a resistance range actually....

    I have not found a resistance range actually. Over the years of checking almost all of them I run across and checking new ones right out of the box for the different manufacturers I have came up with...
  2. Replies
    18
    Views
    1,091

    I can guess what brand furnace that is, in 2...

    I can guess what brand furnace that is, in 2 guesses anyway. That type of furnace requires a specific differential across the heat exchanger and if the pipes are too large it will change the...
  3. Replies
    28
    Views
    4,553

    If the drain system is partially plugged it can...

    If the drain system is partially plugged it can slowly back the water up into the secondary, shut down the furnace, and drain away the secondary leaving water in the inducers without a drain,...
  4. Replies
    42
    Views
    3,826

    I check the resistance on every ignitor I come...

    I check the resistance on every ignitor I come accross. I have a number that if the resistance is close to or over I recommend replacement. I always tell the customer that each ignitor will crack at...
  5. Replies
    8
    Views
    1,297

    I used to replace several mobile home furnaces...

    I used to replace several mobile home furnaces per year. Does the roof jack have the double wall pipe? I have seen a few replacements where the original furnace had an exhaust pipe only and the...
  6. Replies
    20
    Views
    1,428

    Poll: I also find long wait times with Lennox tech...

    I also find long wait times with Lennox tech support, usually worth the wait though.
    The company I work for sells Carrier in MN and the tech support at the wholesale company, both commercial and...
  7. Replies
    112
    Views
    10,378

    If a newwer furnace has an issue with the heat...

    If a newwer furnace has an issue with the heat exchanger it is definately a major problem. It does not take much for the furnace to start sooting up from an impropper air fuel mixture. A combustion...
  8. Replies
    26
    Views
    1,581

    I think the carrier condenser coils are split top...

    I think the carrier condenser coils are split top and bottom, not left and right so if one fan was running on either side of the add on divider it would cool half of 1st stage condenser and half of...
  9. Replies
    26
    Views
    1,581

    Maybe I am not seeing the picture well but is...

    Maybe I am not seeing the picture well but is that cap tube for the fan cycling switch pinched between the condenser coil and the condensing section divider?
  10. Replies
    42
    Views
    2,523

    I now see it looks like that is an 80% model and...

    I now see it looks like that is an 80% model and newwer than I thought. Also it looks like the furnace has a diagnostic light. Did you get a fault code?
  11. Sticky: Hello. Looks like I have made the mistake of...

    Hello. Looks like I have made the mistake of replying to a post before I was supposed to. I guess I was over anxious to see if I could help someone but now I have re-read the rules (a little slower)....
  12. Replies
    42
    Views
    2,523

    As per the AOP Rules only Professional Members *...

    As per the AOP Rules only Professional Members * can reply with
    advice to the OP. Anyone may post and ask questions. They may even
    question the * member answer but not give advice or expand on the...
Results 1 to 12 of 12
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event