  1. It never was clear to me what type of trailer it...

    It never was clear to me what type of trailer it was being put in. I have seen several full size ranges in concession trailers. It's not a problem when it's done correctly. It can not be set up like...
  2. Replies
    13
    Views
    505

    Not to beat a dead horse but is it anywhere near...

    Not to beat a dead horse but is it anywhere near the rated amps? If the voltage is low( we typically find 200 volts in groceries in some areas) The wattage may be down to 4.7 kw as opposed to the...
  3. Replies
    13
    Views
    505

    You have even draw on all three elements? Is the...

    You have even draw on all three elements? Is the voltage correct? Door gaskets and sweeps good? Turn the temp down and see if it cycles at a lower temp. You should be able to see both set and actual...
  4. Replies
    4
    Views
    712

    On the back side of the control door, remove the...

    On the back side of the control door, remove the cover over the control panel. There is a small hole in the center where you can calibrate it but 100 degrees, theres something else wrong. The sensor...
  5. Thread: Manometers

    by Ovenguy
    Replies
    10
    Views
    806

    30 years in the business and I still use a direct...

    30 years in the business and I still use a direct water tube manometer. That's all we supply our techs with for burner manifold adjusting. Yes I have to fill it with water each time I use it but I...
  6. Replies
    3
    Views
    429

    Usually where the pilot tube is connected to the...

    Usually where the pilot tube is connected to the manifold there is a 90 degree fitting with a screw that is a needle valve for the pilot. They can also be inline valves but are typically coming off...
  7. Replies
    7
    Views
    1,829

    We installed just about every Revent bakery oven...

    We installed just about every Revent bakery oven in a Walmart in the Mid-Atlantic region in the past three years including turnkey replacements for aging Baxter/Hobart or Bakers Aids. We were also...
  8. I employ 7 people and I can tell you that will...

    I employ 7 people and I can tell you that will not hold up in a court of law. Ever. They have a right to protect themselves from you leaving and starting your own business and then taking their...
  9. Replies
    1
    Views
    499

    I get mine from Home Depot.

    I get mine from Home Depot.
  10. Replies
    4
    Views
    1,256

    Before you condemn the heat exchanger you should...

    Before you condemn the heat exchanger you should use a combustion analyzer to measure the CO in the baking chamber. Do this by slipping the probe under the door gasket with the burner firing. ...
  11. Sorry, I'm late to see this posting. There are...

    Sorry, I'm late to see this posting. There are electric motor shops all over that could rebuild that pump motor overnight if needed for less then the Hobart price. What voltage and phase is the...
  12. Replies
    41
    Views
    11,946

    This is what I teach to every new tech.

    This is what I teach to every new tech.
  13. Replies
    3
    Views
    1,131

    What model? Does it have a combistat or digital...

    What model? Does it have a combistat or digital controls? I'm not sure what you mean by "it's jumping 20 degrees". All rack ovens ( actually all ovens) will have a temperature swing. What matters is...
  14. Thread: Bakers Aid

    by Ovenguy
    Replies
    6
    Views
    2,107

    Try this...

    Try this
    https://www.dropbox.com/s/y7vrvdure0w9i7c/BARO-2G%2C%20BARO-2E.pdf

    Hobart changed the circulation fan motor to a 3 hp. It involves more than just the motor though. It would be much...
  15. Replies
    6
    Views
    1,979

    That works a little different then Savage Bros....

    That works a little different then Savage Bros. in that the Picard is using a relay to reverse the direction. Is it possible that the gearbox is causing a binding on tilting back up?
  16. Thread: Bakers Aid

    by Ovenguy
    Replies
    6
    Views
    2,107

    Brandon, Hopefully you haven't cut anything up...

    Brandon,
    Hopefully you haven't cut anything up yet. I couldn't post because I could not log in.

    Hobart did not make the BAP proofers. They were made before Hobart bought the company.

    Anyway,...
  17. Replies
    7
    Views
    2,134

    We purchase all of our hoods that we install from...

    We purchase all of our hoods that we install from Captive Aire. Get the list of equipment, the layout, length of duct and amount of turns and call them. They will size the complete proper system for...
  18. Replies
    6
    Views
    1,979

    How does it tilt? Is it a toggle switch? We work...

    How does it tilt? Is it a toggle switch? We work on a lot of savage Bros. bowl lifts and this switch goes out over time.
  19. Replies
    10
    Views
    1,167

    Is this unit anywhere near an exhaust hood and...

    Is this unit anywhere near an exhaust hood and could it be getting a draft from make up air or other sources such as fans that are not always on?

    I would not put safeties on as you would assume...
  20. Replies
    10
    Views
    1,167

    I hate those types of tables. I have one customer...

    I hate those types of tables. I have one customer that still has one. Very dangerous in my opinion. Is it a quarter turn valve with the orifice at the valve? If so these orifices are usually...
  21. Replies
    4
    Views
    1,211

    We use nothing but Captive Aire. Hoods, fans,...

    We use nothing but Captive Aire. Hoods, fans, weldless grease duct, duct wrap, stainless back splash, built in fire suppression, and now factory start up included(at least here in Maryland).
  22. Replies
    7
    Views
    1,064

    If it is LP It should be 10-11"wc at the burner....

    If it is LP It should be 10-11"wc at the burner. LP will burn yellow. Is it sooting up? Is the flame going up the tubes or spilling out the front? Is there any oil in the flame tubes? You did say it...
  23. Replies
    19
    Views
    2,454

    Yeah, I was just thinking that unless you have...

    Yeah, I was just thinking that unless you have been the only one with their hands in it you never know what you might have. And since you mentioned multiple breakers and contractors almost anything...
  24. Thread: Yellow Flames

    by Ovenguy
    Replies
    12
    Views
    2,889

    Are the flames lazy and lifting off of the...

    Are the flames lazy and lifting off of the burner?

    Waltc, you need to start your own thread. This one is about an oven.
  25. Replies
    19
    Views
    2,454

    Is it possible that the last element you turn on...

    Is it possible that the last element you turn on is in series with one of the other 4? Given the info you provided I figure that the first four elements are about 17 ohms creating a current of about...