Search:
Type: Posts; User: dorvs
Search: Search took 0.01 seconds.
-
04-18-2012, 08:46 PM
Thread: HVAC School?
by dorvs- Replies
- 9
- Views
- 1,124
what part of WI are you in? I have a few contacts...
what part of WI are you in? I have a few contacts in that part of the world. Also you can go to the local distributers G.A. Larson,johnstone etc. and talk to the counter people to see if companys are...
-
03-28-2012, 10:46 PM
Thread: TALOR,SOFTSERVE,FREEZINGINTHEHOPPER
by dorvs- Replies
- 4
- Views
- 376
Check the scraper blades for excessive wear. Also...
Check the scraper blades for excessive wear. Also check to make sure the screw is spinning inside. Just because the pully is spinning does not mean screw is. the berings can be junk, you can check by...
-
12-25-2011, 08:53 AM
Thread: TSSU-60-24 troubles
by dorvs- Replies
- 14
- Views
- 811
i would aslo add a O-52hh capt t drier
i would aslo add a O-52hh capt t drier
-
06-18-2011, 12:04 AM
Thread: I'm a newbie that fixed my own AC but...
by dorvs- Replies
- 41
- Views
- 2,566
I have worked at a supply house before and would...
I have worked at a supply house before and would not sell anything to joe blow off the street, not even air filters. To me it was not worth pissing off a contractor who possibly did service for them....
-
06-12-2011, 05:25 PM
Thread: York unit blowing fuses.
by dorvs- Replies
- 24
- Views
- 2,090
where was the voltage corrected? were the...
where was the voltage corrected? were the condenser fan motors rewired in the motors?
-
06-09-2011, 07:47 AM
- Replies
- 4
- Views
- 442
Trane comfortsite you may have to register to be...
Trane comfortsite you may have to register to be able to get to all the good info. But they have service facts from 40 plus years ago.
-
06-05-2011, 09:32 AM
Thread: Problem diagnosing Heat pump
by dorvs- Replies
- 17
- Views
- 2,218
Did you install the correct drier? HP take a 2...
Did you install the correct drier? HP take a 2 way drier.
-
06-04-2011, 02:15 PM
- Replies
- 8
- Views
- 1,188
if you lived down south the higher seer would be...
if you lived down south the higher seer would be worth it. saying that you live in a place where a/c will run possably 2 months a year, and at that it will be hit and miss a day here a day...
-
04-07-2011, 06:04 PM
Thread: Walk in cooler going haywire
by dorvs- Replies
- 27
- Views
- 1,396
if it is only 8 months old it should still be...
if it is only 8 months old it should still be under warranty. get a new compressor then fix what took it out.
-
02-24-2011, 07:30 PM
Thread: oem vs. remanufactured compressors
by dorvs- Replies
- 9
- Views
- 1,129
even oem's rebuild their compressors thats why...
even oem's rebuild their compressors thats why their is a core charge on most of them. they want them back.
-
02-24-2011, 07:24 PM
Thread: Condenser Fan Cycles?
by dorvs- Replies
- 3
- Views
- 498
depending on what part of the country you are...
depending on what part of the country you are from yes. and also the application.
-
01-30-2011, 12:40 PM
Thread: When do you stop looking
by dorvs- Replies
- 49
- Views
- 2,488
I was working on a t49 last week and found a leak...
I was working on a t49 last week and found a leak on the outlet of the evap. coil, right at the face of the steel where the tube comes out. Took some time to pin point.
-
01-11-2011, 08:24 PM
Thread: manurup/danfoss compressors
by dorvs- Replies
- 2
- Views
- 663
manurup/danfoss compressors
anybody haveing issues or problems with them?
-
12-16-2010, 06:04 PM
Thread: Can't please everyone temperature wise
by dorvs- Replies
- 14
- Views
- 833
put a simple stat like a honeywell 1029 to...
put a simple stat like a honeywell 1029 to dissable the condenser when it reaches whatever temp you set it to. when it warms up you'll have a/c again.
-
12-16-2010, 05:54 PM
Thread: BDP 585 help
by dorvs- Replies
- 2
- Views
- 1,639
25 years old they got their money out of it,...
25 years old they got their money out of it, replace it.
-
12-15-2010, 07:47 PM
Thread: carrier control issue
by dorvs- Replies
- 13
- Views
- 628
20 ton breaker was 9 amp
20 ton breaker was 9 amp
-
12-15-2010, 06:53 PM
Thread: carrier control issue
by dorvs- Replies
- 13
- Views
- 628
Found the problem. It was a bad circut breaker....
Found the problem. It was a bad circut breaker. CB1
-
12-14-2010, 08:42 PM
Thread: carrier control issue
by dorvs- Replies
- 13
- Views
- 628
perfect. I will check that as well and no i dont...
perfect. I will check that as well and no i dont have the software. Did not know about it till now. This is the first rtu that i had my hands in with this software. Thanks for the input
-
12-14-2010, 08:33 PM
Thread: carrier control issue
by dorvs- Replies
- 13
- Views
- 628
smokes are smoke detectors. from what i found out...
smokes are smoke detectors. from what i found out today is that the "smokes" that are installed are tempermental to the cold weather that we have had. 20 to 30 below. I have checked rotation and it...
-
12-14-2010, 07:57 PM
Thread: carrier control issue
by dorvs- Replies
- 13
- Views
- 628
and yes the supply fan is vfd. I contacted...
and yes the supply fan is vfd. I contacted carrier tech. support but only managed to piss them off. and they were no help.
-
12-14-2010, 07:54 PM
Thread: carrier control issue
by dorvs- Replies
- 13
- Views
- 628
no codes like that. the code yesterday was for...
no codes like that. the code yesterday was for reverse rotation and today the smokes. Thanks to the button pushers aka maintence guys dont know for sure the #'s.
-
12-14-2010, 07:09 PM
Thread: carrier control issue
by dorvs- Replies
- 13
- Views
- 628
carrier control issue
I have been working on a carrier with a comfort link control for the past 2 days and cant figure it out. The first call was no heat, the only thing the rtu is really use for is a/c in the summer. But...
Results 1 to 22 of 23

