    Critical Room Control Have used quite a few with...

    Critical Room Control
    Have used quite a few with great results in multiple hospital environments.

    http://www.criticalroom.com/
  2. Replies
    4
    Views
    530

    2 DOs: I would Link a Start/Stop block into the...

    2 DOs: I would Link a Start/Stop block into the 'or' of 2 logic blocks. Set the 2nd logic 'or' as 'not'. Logic outputs to DOs. Proxy out the start/stop as nvimanocc. This should be the easiest...
  3. Replies
    4
    Views
    530

    Do you mean a manual over-ride of a hardware...

    Do you mean a manual over-ride of a hardware output?
    Simplest way: connect a Setpoint to a logic block - logic block to an output. Proxy out the setpoint to AX. Write to your setpoint thru AX. ...
  4. Replies
    5
    Views
    1,115

    Configure your hardware point AI in the 15C as...

    Configure your hardware point AI in the 15C as 'Outside air Temp' and download the controller. In Distech, drop an nvi point on your programming wiresheet and name it 'nviOaTemp' or whatever you...
  5. Thread: Lon Bindings

    by The Dog
    Replies
    3
    Views
    590

    They will only show up in the Link Manager if...

    They will only show up in the Link Manager if they are actual Lon Links - you have to link from controller to controller, not proxy point to proxy point. If done correctly, the links will show on...
  6. Thread: Tschüss

    by The Dog
    Replies
    13
    Views
    1,454

    Now what did he say?!?! I must have missed sumpin

    Now what did he say?!?! I must have missed sumpin
  7. Thread: smart controls

    by The Dog
    Replies
    11
    Views
    1,379

    Hopefully no one in your area is already a...

    Hopefully no one in your area is already a dealer, they won't sell in my area as another contractor already has my territory.
  8. Thread: smart controls

    by The Dog
    Replies
    11
    Views
    1,379

    try here: http://diviotech.com/

    try here: http://diviotech.com/
  9. Replies
    7
    Views
    653

    I just did it with my laptop through a browser,...

    I just did it with my laptop through a browser, but I have the plug-ins loaded on my machine.
    Just tried it with another office computer without workbench or the plugins and could not do it. I...
  10. Thread: AX Plug Ins

    by The Dog
    Replies
    8
    Views
    564

    Distech does: fully programmable, application...

    Distech does: fully programmable, application specific, and I/O modules. I like 'em!
  11. Thread: JACE 200

    by The Dog
    Replies
    13
    Views
    1,371

    SomeOldGuy - are/were you planning on using the...

    SomeOldGuy - are/were you planning on using the I/O 34 for controlling the VAV boxes? I would suggest using a lon VAV controller for each vav box. Which means that you need to buy the lon driver...
  12. Replies
    8
    Views
    573

    Are all the needed modules loaded on the...

    Are all the needed modules loaded on the supervisor machine?
  13. Replies
    3
    Views
    505

    Thanks. Further research revealed that Siemens...

    Thanks.

    Further research revealed that Siemens has their own apogee to net 8000 driver. Looks like they go rs-485 to rs-232 to the GCM. good news for me.

    Again, thanks for the info.
  14. Replies
    3
    Views
    505

    Siemens and Network 8000 GCM

    DOes anyone know how Siemens would take over an Invyensys Network 8000 GCM? Do they comm to the GCM and leave it in place or do they remove the GCM and communicate on the ASD wire? Local branch is...
  15. Replies
    0
    Views
    309

    JCI 'XFT' System

    Anyone ever hear of a 'JCI XFT Control System Headend'? Is it an old branch thingy? Is there any way to bring this 'system inta an FX60?
  16. Thread: i quit

    by The Dog
    Replies
    28
    Views
    1,953

    9 months ago, I did the exact thing you have just...

    9 months ago, I did the exact thing you have just done. Probably the best move in my life, besides getting married. Don't be fooled, some things will be tough, it ain't going to be all gravy. ...
  17. Replies
    5
    Views
    593

    Jogas, Check your gmail, I couldn't attach here -...

    Jogas, Check your gmail, I couldn't attach here - to big and to lazy. Feel free to distribute here.
  18. Replies
    6
    Views
    446

    Even the XL500 is being replaced with the XL800. ...

    Even the XL500 is being replaced with the XL800. You can still buy some 500 parts, but once they are gone - no more.
  19. Replies
    6
    Views
    446

    I'm not sure if it being phased out (probably?),...

    I'm not sure if it being phased out (probably?), but it is definitely C-bus only - the last I heard from my Honeywell supplier.
  20. If you are not using Tridium, then Distech is...

    If you are not using Tridium, then Distech is your only choice. Spiders can only be programmed in the Tridium AX environment. Distech has free LNS plugins and Tridium plugins.
  21. Replies
    4
    Views
    475

    will the station run on your laptop? What does...

    will the station run on your laptop?
    What does the standard output say? the error most likely will show up there.

    If it doesn't, save a backup of the station somewhere, open the station offline...
  22. Replies
    11
    Views
    1,027

    Just thought of another item. I believe that the...

    Just thought of another item. I believe that the Jace has to be the end of the line of the near side (other end of the router)of the LonNetwork, but I could be mistaken.
  23. Replies
    11
    Views
    1,027

    "After the LON router is added using the external...

    "After the LON router is added using the external network mgmt tool, does the JACE Device need to "discover", or "learn" the network to "find" the LON router?"

    OK, I just saw this. You need to go...
  24. Replies
    11
    Views
    1,027

    Unless I am reading this wrong, you will need to...

    Unless I am reading this wrong, you will need to put the router in "temporary repeater' (the term may not be exactly right) mode and commission the controllers for subnet 6 and then put the router...
  25. Replies
    3
    Views
    569

    there is a decent company in Grand Rapids , MI...

    there is a decent company in Grand Rapids , MI looking. They had an ad sitting on the counter in the supply house. Call Cochrane supply in GR, they will point you in the right direction.
Results 1 to 25 of 45
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event