Search:

Type: Posts; User: zibby

Page 1 of 10 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    45
    Views
    1,791

    Did he put a pressure gauge on to see if there is...

    Did he put a pressure gauge on to see if there is a leak?
  2. Replies
    45
    Views
    1,791

    Standard test is 3psi for 15min with isolated gas...

    Standard test is 3psi for 15min with isolated gas valves (to prevent valve damage) and gas meter
  3. When unit locks out, does it give a error code?

    When unit locks out, does it give a error code?
  4. Thread: Rooftop unit ID

    by zibby
    Replies
    5
    Views
    333

    Just PM unit. I got 5 of them

    Just PM unit. I got 5 of them
  5. Thread: Rooftop unit ID

    by zibby
    Replies
    5
    Views
    333

    Rooftop unit ID

    Looking for some info on the unit (installation/service manual). Old washed out label says YORK. ID tag unreadable.
    Thanks.
    443521
  6. Replies
    1
    Views
    164

    Get system capable of up to 8 units. Price would...

    Get system capable of up to 8 units. Price would probably be slightly higher then 2 separate units
  7. Replies
    22
    Views
    899

    Neat. I prefer plastic lineset cover

    Neat. I prefer plastic lineset cover
  8. Pex in pvc sounds ok

    Pex in pvc sounds ok
  9. Replies
    4
    Views
    432

    Get propane torch and fix it. Try not to burn...

    Get propane torch and fix it. Try not to burn down your house, :)
  10. Replies
    8
    Views
    608

    As said by DDC_Dan, they are not bond by NEC...

    As said by DDC_Dan, they are not bond by NEC codes, just like power utility workes bringing power to your house.
  11. Sounds good to me

    Sounds good to me
  12. Replies
    16
    Views
    1,798

    You hired a plumber. Thats a first mistake.

    You hired a plumber. Thats a first mistake.
  13. Not correct about indirect tank

    Not correct about indirect tank
  14. With indirect tank 80,000 btu would be a min. Mod...

    With indirect tank 80,000 btu would be a min. Mod condensing boiler will modulate to your load (with right setup)
  15. Got it online.

    Got it online.
  16. Replies
    11
    Views
    620

    5000uF capacitor on DC side will fix it.

    5000uF capacitor on DC side will fix it.
  17. If you pay for travel expense, then I'll come...

    If you pay for travel expense, then I'll come over and fix it.
  18. Replies
    11
    Views
    620

    Make sure your rectifier has higher amps rating...

    Make sure your rectifier has higher amps rating than your total load ( bigger rectifiers need heatsink)
  19. Replies
    10
    Views
    1,127

    Didn't red tag it?

    Didn't red tag it?
  20. Thread: Reach in cooler

    by zibby
    Replies
    10
    Views
    1,509

    True

    True
  21. Thread: Reach in cooler

    by zibby
    Replies
    10
    Views
    1,509

    If cap tube was clogged, than your low side would...

    If cap tube was clogged, than your low side would go in vacuum. Check your start components, probably ptc is bad.
  22. BS

    BS
  23. Replies
    4
    Views
    738

    proobably wont work. Lots of programms durring...

    proobably wont work. Lots of programms durring installation set path in registry file. Simply comping files will not thell windows where they are.
  24. Replies
    10
    Views
    1,347

    make sure no gas valves are connected to that...

    make sure no gas valves are connected to that pipe. 15' would damage them.
  25. Replies
    10
    Views
    1,347

    test at 3lb for 15 min with no pressure loss. If...

    test at 3lb for 15 min with no pressure loss. If left overnight, temp drop may cause the pressure loss (there is a way to calculate it)
Results 1 to 25 of 237
Page 1 of 10 1 2 3 4