Search:

Type: Posts; User: Brimm

Search: Search took 0.00 seconds.

  1. Replies
    6
    Views
    1,918

    I know it is no moer that a 5 ton system any...

    I know it is no moer that a 5 ton system any larger and the condensor part would be differant the carrier in the background is probly the same size do you have a model on it?
  2. Replies
    5
    Views
    614

    I have seen sthomthing like that done before were...

    I have seen sthomthing like that done before were a r-12 stetem on a theater was switched to a chill water the txv's and distribuer tubes were puled the cooling cap just about the same but this was a...
  3. Replies
    6
    Views
    1,169

    it lokes like the filter dryer did come apart. ...

    it lokes like the filter dryer did come apart. had the system ben opeaned or reparied befor
  4. Replies
    15
    Views
    5,049

    see if you can get the start upon the chiller if...

    see if you can get the start upon the chiller if you dont have it you should be able to get it carrier you might have to have the bulding owner call carrier to get this but carrier will have it in...
  5. Replies
    12
    Views
    2,055

    This sounds like it may be a air flow issue have...

    This sounds like it may be a air flow issue have you checked the fire dampners
  6. Thread: Carlyle comp.

    by Brimm
    Replies
    28
    Views
    2,419

    What is the super heat on the evap. sounds like...

    What is the super heat on the evap. sounds like it could be freazing up
  7. Replies
    20
    Views
    6,594

    I have had the same problem on a copland. but at...

    I have had the same problem on a copland. but at first it would have about 25 # after 10 minutes it would start to lose oil #
  8. Replies
    6
    Views
    968

    what I was taught in school 25 years ago was to...

    what I was taught in school 25 years ago was to try a larger mfd and see if theamps go up or down. the best wil draw the least amps. but that was befor dirt.
  9. Replies
    23
    Views
    2,946

    Could you please shoot me a copy as well. E-mail...

    Could you please shoot me a copy as well. E-mail is in my profile. Thanks
  10. Thread: Newbie

    by Brimm
    Replies
    14
    Views
    1,050

    Hi the first thing you need to know is more info...

    Hi the first thing you need to know is more info what is the super heat what is the condensing temp. is thier any subcooling. is thier a delta t across the evap. you dont have all the info you need...
  11. Replies
    3
    Views
    1,090

    Hi I have worked with sevral 23xl chillers and...

    Hi I have worked with sevral 23xl chillers and hvae had the same slide valve problem at about 50,000 hours of run time but living in south texas thay run about 10 monts a yearcarrier recomends thay...
  12. Replies
    34
    Views
    3,223

    It seams to me that the belts with the smaller...

    It seams to me that the belts with the smaller pullys and sheavs wear out the fastest.
  13. Thread: P. H.

    by Brimm
    Replies
    2
    Views
    347

    thank you Don:) :) :)

    thank you Don:) :) :)
  14. Thread: P. H.

    by Brimm
    Replies
    2
    Views
    347

    P. H.

    what should the P.H. be on a water cooled water tower?:cool:
  15. Replies
    0
    Views
    513

    siebe to wifi ???

    I have the old siebe or ( invensys) D.D.C control system and we would like to upgrade to a wifi system ( if possible) any help would be helpfull.
  16. Replies
    6
    Views
    2,604

    invensys

    you might try searching for invensys. siebe changed its name.
Results 1 to 16 of 17
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event