Search:
Type: Posts; User: Bergen D
Search: Search took 0.01 seconds.
-
01-02-2013, 10:53 PM
Thread: 404a pressures in low
by Bergen D- Replies
- 15
- Views
- 1,133
Will return to site and check. I know bulb is...
Will return to site and check. I know bulb is making good contact because I removed bulb and heater up to check txv operation. Thanks for the help. Will check back in
-
01-02-2013, 09:21 PM
Thread: 404a pressures in low
by Bergen D- Replies
- 15
- Views
- 1,133
Checked pressures again after box dropped from 35...
Checked pressures again after box dropped from 35 degrees to 10 degrees after running for a few... 23 psi suction, 225psi head pressure. 20 degree super heat at evap coil. Total system...
-
01-02-2013, 06:35 PM
Thread: 404a pressures in low
by Bergen D- Replies
- 15
- Views
- 1,133
Sporlan head pressure control valve LAC 4 215...
Sporlan head pressure control valve
LAC 4 215
Also found a heat exchanger about 10' from rooftop condensing unit heating up suction line with liquid line between indoor and outdoor units -
01-02-2013, 03:12 PM
Thread: 404a pressures in low
by Bergen D- Replies
- 15
- Views
- 1,133
404a pressures in low
I have a r-404a roof-top condensing serving a walk in freezer. pressures are 235 psi head pressure and a 28psi suction pressure. Outdoor ambient is 30degress and indoor box temperature is about...
-
07-01-2008, 08:31 AM
- Replies
- 17
- Views
- 1,346
fieldpiece fuse
I have a fieldpiece HS36 and went thru a couple of fuses thru the years. Remove the battery and remove all the small phillips head screws on the back of the meter. The case pulls apart and you will...
-
06-30-2008, 11:07 AM
Thread: New York City splits
by Bergen D- Replies
- 4
- Views
- 368
added crankcase heaters, low ambient fan...
added crankcase heaters, low ambient fan controls, bypass timers, hi-lo pressure switches, time delays, the works. After one month of use both the ncps and aerosys systems rattle like they are...
-
06-30-2008, 10:02 AM
Thread: New York City splits
by Bergen D- Replies
- 4
- Views
- 368
New York City splits
hvac contractor working in Nyc, mostly between 5th ave and park ave $$$$. Have found almost all equipment to be National Comfort products or Aerosys thru wall condensing systems. Compressers short...
Results 1 to 7 of 7