    I wondered if you wired a light switch in then...

    I wondered if you wired a light switch in then after it lit and spark was done put your meter on the terminals and turn switch off and just feed the current through the meter to the board
  2. Replies
    26
    Views
    2,568

    Cordless Band saw or large ridgid pipe cutter....

    Cordless Band saw or large ridgid pipe cutter. Cordless grinder to bevel pipe after cutting
  3. Replies
    76
    Views
    3,408

    Hmm check standby setting on sentry controller...

    Hmm check standby setting on sentry controller sounds like its maybe on zero
  4. Replies
    39
    Views
    2,218

    One of the inspectors gave me a key to unlock the...

    One of the inspectors gave me a key to unlock the meter. He also said I could unlock it to test fire the new appliance, after a quick test fire I close the lockwing and relock it.
  5. Do it right the first time get a boiler. The...

    Do it right the first time get a boiler. The tankless heat exchanger is way too thin to be used as a boiler long term.
  6. Sounds like the sentry controller keeping the...

    Sounds like the sentry controller keeping the plate HX warm this can be adjusted for the amount of time it will run for, it helps to ensure a quick supply of hot water after the initial call for DHW
  7. NTI Trinity all the way. Piping isn't that...

    NTI Trinity all the way. Piping isn't that complicated just a quick primary/secondary or injection, depending on what you want
  8. No issues with that vent termination, just ensure...

    No issues with that vent termination, just ensure there is a bird screen installed in it. As previously mentioned any rain will drain the same way as if it was condensate running down.
  9. Replies
    63
    Views
    3,292

    Picquick screwdrivers are da bomb no breakage,and...

    Picquick screwdrivers are da bomb no breakage,and tough as nails

    http://www.picquic.com/bro-english.html
  10. Replies
    15
    Views
    835

    Like everyone else says 40 gal indirect as a...

    Like everyone else says 40 gal indirect as a storage for volume
  11. Replies
    12
    Views
    519

    As indicated below Baseboards and radiators and...

    As indicated below Baseboards and radiators and also forced air supply ducts are located under windows to throw up a warm curtain of air on front of an area that may give you a cold draft feeling and...
  12. Replies
    16
    Views
    1,225

    I have seen in a customer's home 3 different...

    I have seen in a customer's home 3 different readings from 3 different detectors in the same room. All this when my calibrated tester showed nothing.

    :anyone: Why do people call the fire...
  13. P-trap where the proposed new drain line ties...

    P-trap where the proposed new drain line ties into the plumbing. The drain shouldn't be hardpiped to the ABS in case it backs up, it needs an air gap. Unless you want to do it forced air style and...
  14. Not the ideal way! there must be some way to tie...

    Not the ideal way! there must be some way to tie into the plumbing system from the attic then p-trap it
  15. Replies
    9
    Views
    996

    That's the first time I have heard of an...

    That's the first time I have heard of an intermittent problem on an HSI usually they die completely.
  16. Replies
    10
    Views
    649

    Call a pro gas furnaces are dangerous to diy

    Call a pro gas furnaces are dangerous to diy
  17. I couldn't agree more. Why burn and exhaust air...

    I couldn't agree more. Why burn and exhaust air you have paid to heat?
  18. Replies
    5
    Views
    381

    My preference is to keep the mechanical room all...

    My preference is to keep the mechanical room all together, in one well lit room.
    To run the piping to a remote indirect tank location may incur a larger cost to install and if not properly insulated...
  19. Replies
    5
    Views
    381

    The boiler shouldn't have to run for very long to...

    The boiler shouldn't have to run for very long to just heat the tank. Just be sure to have heat traps installed in the piping to prevent heat creep, or have flow checks installed to prevent the...
  20. That depends on what type of system you have, and...

    That depends on what type of system you have, and what temps you are running in your system. A 2 temp system can be installed but at more cost.
    I am a fan of boilers if you already have one use it
  21. Replies
    8
    Views
    1,038

    Open systems are a BAD idea, do you want stagnant...

    Open systems are a BAD idea, do you want stagnant floor (heating) water coming out of your faucet. Also new water all the time will lead to corrosion/mineral deposits. I have seen a few wirsbo...
  22. The NTI Trinity boilers are very common in the...

    The NTI Trinity boilers are very common in the Ottawa area with parts readily available. I am installing one right now in downtown Ottawa.
    Weil McLain Ultras have a reliability issues and I no...