10-11-2012, 05:30 PM
Thread: Energy Star 3.0 RNC homes
by bigwave- Replies
- 1
- Views
- 424
Energy Star 3.0 RNC homes
For all you Idaho, WA and MT HVAC Co. Here in Oregon we are going to energy star 3.0 in 2013. I know that the previous mentioned states went 3.0 in 2012.
My question is how was the transition? How... -
02-29-2012, 10:22 PM
Thread: Cfm equation gas furnace
by bigwave- Replies
- 28
- Views
- 1,174
I am sorry I am all over the place. If I took a...
I am sorry I am all over the place. If I took a ESP reading with my manometer and the return temp was 50 deg would I have a lower static than if taken at 70 deg
-
02-29-2012, 10:17 PM
Thread: Cfm equation gas furnace
by bigwave- Replies
- 28
- Views
- 1,174
That is how my question started. So with at least...
That is how my question started. So with at least 2 numbers and correction factor btu out, cfm can figure ^t....... btu out, ^t can figure cfm.
-
02-29-2012, 10:00 PM
Thread: Cfm equation gas furnace
by bigwave- Replies
- 28
- Views
- 1,174
So aside for assuming the name plate is correct...
So aside for assuming the name plate is correct how would you get the correct btu output?
-
02-29-2012, 09:58 PM
Thread: Cfm equation gas furnace
by bigwave- Replies
- 28
- Views
- 1,174
sorry I was trying to quote Gravity when asking...
sorry I was trying to quote Gravity when asking how I got BTU output
-
02-29-2012, 09:53 PM
Thread: Cfm equation gas furnace
by bigwave- Replies
- 28
- Views
- 1,174
I would like to tell you a combustion analyzer....
I would like to tell you a combustion analyzer. This is more of something I was thinking of and not a real world situation. Normally I have a blower chart and use my manometer.
-
02-29-2012, 09:25 PM
Thread: Cfm equation gas furnace
by bigwave- Replies
- 28
- Views
- 1,174
Cfm equation gas furnace
With no blower chart on a gas furnace what is the equation to figure airflow? Is it btu output/temp rise/1.08 = cfm? I cant remember. I would like to get me post count up so I can really benifit from...
-
01-03-2012, 08:47 PM
Thread: Duel fuel low voltage short
by bigwave- Replies
- 9
- Views
- 303
The transformer. I am assuming you are not being...
The transformer. I am assuming you are not being a Smart A:censored: like the others. This site is good and the few arrogant pr:censored: on here shouldn't ruin it. AOP ? I thought the P stood for...
-
01-03-2012, 07:52 PM
Thread: Duel fuel low voltage short
by bigwave- Replies
- 9
- Views
- 303
Duel fuel low voltage short
I have a duel fuel Tempstar T9MPV125 with a Tempstar T4H7060 2 stage Heat pump. I have the system zoned into 3 zones, Eac and humidifier.
This story covers a couple of months of on again off again... -
11-03-2011, 05:40 PM
Thread: No manual J with furnace only - follow-up
by bigwave- Replies
- 16
- Views
- 840
Tempstar has a 40k btu 95%. T9MVX40F12.... Sorry...
Tempstar has a 40k btu 95%. T9MVX40F12.... Sorry missed the Modulating.. They do have a mod coming out not sure if there will be a 40k.
-
10-08-2011, 07:13 PM
Thread: Static Pressure.
by bigwave- Replies
- 30
- Views
- 1,685
Static
I was told that esp should be taken distance of 2.5 times the diameter of the blower wheel from the center of the blower shaft.
-
08-24-2011, 09:06 PM
Thread: Compressor makes loud bang sound
by bigwave- Replies
- 8
- Views
- 1,255
I thought it may be a restriction. In order for...
I thought it may be a restriction. In order for it to shoot up that fast wouldn't it have to be a complete restriction and the suction pressure drop? Why does it run without pumping.
-
08-24-2011, 08:39 PM
Thread: Compressor makes loud bang sound
by bigwave- Replies
- 8
- Views
- 1,255
Compressor makes loud bang sound
I am dealing with a Bryant 3 ton 410a split system ac. Customer reported the AC making a loud banging noise on start up. I put my gauges on and started the unit. In the off position the gauges read...
-
06-22-2011, 01:21 PM
Thread: Sudden loss of charge?
by bigwave- Replies
- 9
- Views
- 463
Yes I am in the biz. I am not NATE. I have...
Yes I am in the biz. I am not NATE. I have checked with a holegen leak detecter and soap bubbles and looked for oil spots.
The outword crack in the liquid service valve cap has me baffled. Maybe... -
06-22-2011, 12:42 PM
Thread: Sudden loss of charge?
by bigwave- Replies
- 9
- Views
- 463
Sudden loss of charge?
I have a Tempstar 5 ton 2 stage heat pump in a 4000 sq ft house. The house is seperated into 3 zones.
Here is my problem. My system was operating and heating the house just fine (I HAVE NO BACK UP... -
06-16-2011, 03:43 PM
Thread: What are you Thoughts?
by bigwave- Replies
- 11
- Views
- 357
2 stage ?
Is your AC a 2 stage? It sounds as if it is and it is operating on the first stage.