    What do the Timberland pro's look like? Are they...

    What do the Timberland pro's look like? Are they steel toe?
  2. Replies
    30
    Views
    2,191

    I also wear red wing. They cost about $200. The...

    I also wear red wing. They cost about $200. The boots that I bought, have a protective black rubber over the steel toe. Bare leather wears a hole down to the steel toe, quick. I wear them everyday, ...
  3. Replies
    2
    Views
    225

    Strykers are configurable through the tstat...

    Strykers are configurable through the tstat (tr71). Spider requires honeywell workbench.
  4. Replies
    16
    Views
    706

    I didn't mean to question your experience, sorry....

    I didn't mean to question your experience, sorry. I'm out in California and most building that I see were built with some mechanical planning. If you don't have the things that I mentioned, then you...
  5. Replies
    16
    Views
    706

    Most closed loop systems have a make-up,fast fill...

    Most closed loop systems have a make-up,fast fill & prv station. I doubt the building engineer disigened that system to be filled the way you explained. Lol... your a clever guy!
  6. Replies
    2
    Views
    397

    Ding Dind Ding... you got it! Thanks :)

    Ding Dind Ding... you got it! Thanks :)
  7. Replies
    2
    Views
    397

    What make is this evap coil?

    Mountain aire? I cant find any info online. Im having395341 issues with the refrigerant/txv/not sure...
  8. Replies
    42
    Views
    4,903

    I ohmed the new motor right out of the box. The...

    I ohmed the new motor right out of the box. The motor only has 3 leads, black, yellow and brown. I just checked from one lead to another. I checked the old motot the same way, with the motor leads...
  9. Replies
    42
    Views
    4,903

    But the resistances were that way on the old and...

    But the resistances were that way on the old and the new motor. The new motor runs within it's rating.
  10. Replies
    42
    Views
    4,903

    Has anyone ever ohmed out a single phase motor...

    Has anyone ever ohmed out a single phase motor and got 3 similar resistances?
  11. Replies
    42
    Views
    4,903

    You guys are absolutely right! When I got zapped...

    You guys are absolutely right! When I got zapped I was repositioning the lid because I removed it to install the cc heater. The motor leads were still connected and the screws to the lid were not...
  12. Replies
    42
    Views
    4,903

    When the unit "zapped" me it was only a tingle. ...

    When the unit "zapped" me it was only a tingle.

    So, if the unit was properly grounded I should have felt absolutely nothing?

    The breaker only trips when there is high amperage, right? So, if...
  13. Replies
    42
    Views
    4,903

    Sorry... the wire nuts that attatch the the cc...

    Sorry... the wire nuts that attatch the the cc heater leads were laying in water in the botttom of the unit. So, that did trip the breaker at the roof panel and at the breaker down stairs.
  14. Replies
    42
    Views
    4,903

    Timebuilder, does this "bonding jumper" weaken...

    Timebuilder, does this "bonding jumper" weaken when there is a large flow of current through it? The cc heater in the unit
  15. Replies
    42
    Views
    4,903

    Im sorry, I ment to say my meter read "OL" when I...

    Im sorry, I ment to say my meter read "OL" when I checked from the motor leads to the motor frame.

    This motor came from the factory with just 3 leads (common, start and run) and no ground wire. ...
  16. Replies
    42
    Views
    4,903

    This unit is a Carrier M/n: 38YCC036630 S/n:...

    This unit is a Carrier
    M/n: 38YCC036630
    S/n: 1002E30967
  17. Replies
    42
    Views
    4,903

    So.... the old motor was not grounded. Right?...

    So.... the old motor was not grounded. Right? But, it was, I replaced it and now the is no more voltage on the cabinet.

    Maybe my meter is not powerful enough the detect that small of a resistance...
  18. Replies
    42
    Views
    4,903

    This unit was grounded. It's supplied with 3 leg...

    This unit was grounded. It's supplied with 3 leg @ 460 and 1 ground wire. The cond motor is stud mounted. I did check the motor from each lead to the motor frame and found no resistance.
  19. Replies
    42
    Views
    4,903

    1 phase 460v cond. motor?

    Today I was zapped bt the chassis of a condensing unit. I changed a cc heater on this unit because it shorted out in a puddle of water. I energized this unit after installing the new cc heater and...
  20. Replies
    8
    Views
    1,169

    Ok... Check the manufactures wiring diagram and...

    Ok... Check the manufactures wiring diagram and the sequence of operations. If your getting power in... And no power out, then that's a bad module/board.
  21. Replies
    8
    Views
    1,169

    Are you getting 24 volts to the module on a call...

    Are you getting 24 volts to the module on a call for heating?
  22. Replies
    8
    Views
    1,169

    Does #2 have a pressure switch to prove the draft...

    Does #2 have a pressure switch to prove the draft motor? Is the switch working? If the flue gets blocked the switch wont stroke and the module wont spark.
  23. Replies
    12
    Views
    2,487

    oh yeah, dont leave the econmizer bypassed....

    oh yeah, dont leave the econmizer bypassed. Figure out what's wrong and explain all the benefits of the economizer to the customer. Fix it.
  24. Replies
    12
    Views
    2,487

    I've also had the CLO board short out and kill...

    I've also had the CLO board short out and kill fuses. Definitely get a resettable 5amp breaker. Take your time and check the wiring diagram. if you don't have the economizer "bypass jumper harness"...
  25. Replies
    13
    Views
    3,192

    The micron gauge is in the center port. You need...

    The micron gauge is in the center port. You need to have one valve on the manifold open to the system and have a valve between the center port and the vacuum pump closed in order to isolate the...
  26. Replies
    28
    Views
    9,395

    Read the book on that cond. Unit. I know with...

    Read the book on that cond. Unit. I know with some Carriers, they have to be running in high capacity or you'll get funny pressure reading. Also check if the indoor blower is running in high speed.
  27. I've worked on a couple ice machines, so I ...

    I've worked on a couple ice machines, so I belive you guys when you say they can be disgusting.

    However, since were talking about the unknown nastyness thats close to home, we have a new acct....
  28. Sticky: I'll bet you wish you had that R-22 back. That...

    I'll bet you wish you had that R-22 back. That stuff has gone through the roof out here in CA.
  29. Replies
    12
    Views
    1,410

    Yeah sounds like you know a thing or two... I...

    Yeah sounds like you know a thing or two... I found a pdf file online that showed me how to change the occ temp set point. So I drop the set point about 10 ° and after a few short delays...the comps...
  30. Replies
    12
    Views
    1,410

    Ok I'll check out the solenoids tomorrow. Thanks...

    Ok I'll check out the solenoids tomorrow. Thanks again...
  31. Replies
    12
    Views
    1,410

    This unit has a bunch of terminal blocks. I was a...

    This unit has a bunch of terminal blocks. I was a little overwhelmed, i didn't want to jump the wrong terminals. Do you know exactly which ones to jump. Or am i making this more complicated then it...
  32. Replies
    12
    Views
    1,410

    Yes they are pump down systems. This unit has 4...

    Yes they are pump down systems. This unit has 4 scroll comps.
  33. Replies
    12
    Views
    1,410

    Yeah the blowers run continuously. I'm sorry what...

    Yeah the blowers run continuously. I'm sorry what is the "TB"?

    tkanks,
  34. Replies
    12
    Views
    1,410

    McQuay rps045csa

    Ok guys im looking for some help. I've been a full time tech for about 2mo. For the past year I've been a parts guy/tech. the company i work for does mostly comercial with a few residentials mixed in...
  35. Thread: hi everyone

    by jarganda83
    Replies
    5
    Views
    881

    I know dandyme be 'patient' lol. I dont mind...

    I know dandyme be 'patient' lol. I dont mind cleaning the restrooms, that builds character. The way I see it is the more you know, the more your worth. I want to learn more, so I can get paid more....
  36. Thread: hi everyone

    by jarganda83
    Replies
    5
    Views
    881

    Hey thanks Paul bee for those links. I like that...

    Hey thanks Paul bee for those links. I like that one from carrier. does carrier offer any free charts or other online lititure?
  37. Thread: hi everyone

    by jarganda83
    Replies
    5
    Views
    881

    hi everyone

    this is my first post. I've checked this site for info in the past. So I finaly decided to join the team. I hope I can help others even though im new to the industry. I just received an A.S. In HVAC...
Results 1 to 37 of 43
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event