Search:

Type: Posts; User: zibby

Page 1 of 6 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    46
    Views
    2,268

    I hate to see orange wire nut on 2 18ga wire....

    I hate to see orange wire nut on 2 18ga wire. Drives me bananas
  2. Replies
    6
    Views
    398

    All he has is boiler with 2 zones. If spare wire...

    All he has is boiler with 2 zones. If spare wire is missing then he needs to run new 18/3
    R,W and C
  3. Replies
    6
    Views
    398

    Manufacturer saving on ink. If boiler doesnt...

    Manufacturer saving on ink.
    If boiler doesnt have C then go directly to transformer
  4. Replies
    144
    Views
    3,432

    Jump up when you do it

    Jump up when you do it
  5. Replies
    46
    Views
    2,268

    Per OSHA 1910.333(a)(1), live parts to which an...

    Per OSHA 1910.333(a)(1), live parts to which an employee may be exposed must be de-energized before the employee works on or near them, unless the employer can demonstrate that de-energizing...
  6. Replies
    46
    Views
    2,268

    OSHA regulations does

    OSHA regulations does
  7. Replies
    6
    Views
    398

    R or RH - power for heat RC - power for cooling...

    R or RH - power for heat
    RC - power for cooling
    They have jumper between if both are powered from single transformer
  8. Replies
    46
    Views
    2,268

    Tell sparky to suck it

    Tell sparky to suck it
  9. Replies
    144
    Views
    3,432

    Make sure you pee distilled water.

    Make sure you pee distilled water.
  10. Replies
    144
    Views
    3,432

    Because it's connected to same ground as your...

    Because it's connected to same ground as your body is. You can touch hot leg with your tong as long as you are isolated from ground. Just like birds siting on power line wires
  11. Replies
    144
    Views
    3,432

    Think about as hot and neutral carry current,...

    Think about as hot and neutral carry current, except neutral is connected to ground (for 120v only)
  12. Thread: Honeywell Lyric

    by zibby
    Replies
    2
    Views
    235

    And they're ugly lol

    And they're ugly lol
  13. Thread: Honeywell Lyric

    by zibby
    Replies
    2
    Views
    235

    Honeywell Lyric

    So Honeywell sent me Lyric tstat to test-drive it. I took out Nest and installed Lyric. Installation was a breeze, but that's about it.
    So lets start with design. Subbase is ok, has a rubber gasket...
  14. Replies
    8
    Views
    645

    "The van was carrying chlorine and muriatic acid,...

    "The van was carrying chlorine and muriatic acid, both of which were spilled onto the roadway."

    Hope the driver is ok



    Sent from my iPad using Tapatalk HD
  15. Cant wait to see what the charge is. They...

    Cant wait to see what the charge is. They shouldnt waste any meds on him. Just fry his ass on electric chair right away, or better, just hacksaw his head off - Jack Bauer style.


    Sent from my...
  16. I have Testo 330 V2 with color screen, customer...

    I have Testo 330 V2 with color screen, customer database (with option to save data to print out or save at office for record) Sensors last 4 years and are easy to swap. It has CO sensor protection...
  17. Replies
    30
    Views
    1,748

    I just laugh at stupid questions. Now to answer...

    I just laugh at stupid questions.
    Now to answer your question, as long as you zero your gauges (move needle to 0) you should be all set. Your atmospheric pressure isnt gonna change -+10psi to have...
  18. Replies
    30
    Views
    1,748

    why would you work in rain and get your tools...

    why would you work in rain and get your tools wet?

    Sent from my iPad using Tapatalk HD
  19. Replies
    10
    Views
    490

    Hvac protected by gfci? Really? You need to hire...

    Hvac protected by gfci? Really? You need to hire new electrician. The only gfci should be auxiliary service outlet (dedicated home run) within 25ft from equipment.
  20. Replies
    29
    Views
    2,086

    Mine died after a year (just past the warranty)....

    Mine died after a year (just past the warranty). It want able to pull below 2000. Supply house sent it to manufacturer for a repair. $200 and 2 weeks later I got the pump back. So far works like a...
  21. Replies
    45
    Views
    2,743

    Did he put a pressure gauge on to see if there is...

    Did he put a pressure gauge on to see if there is a leak?
  22. Replies
    45
    Views
    2,743

    Standard test is 3psi for 15min with isolated gas...

    Standard test is 3psi for 15min with isolated gas valves (to prevent valve damage) and gas meter
  23. When unit locks out, does it give a error code?

    When unit locks out, does it give a error code?
  24. Thread: Rooftop unit ID

    by zibby
    Replies
    5
    Views
    558

    Just PM unit. I got 5 of them

    Just PM unit. I got 5 of them
  25. Thread: Rooftop unit ID

    by zibby
    Replies
    5
    Views
    558

    Rooftop unit ID

    Looking for some info on the unit (installation/service manual). Old washed out label says YORK. ID tag unreadable.
    Thanks.
    443521
  26. Replies
    1
    Views
    223

    Get system capable of up to 8 units. Price would...

    Get system capable of up to 8 units. Price would probably be slightly higher then 2 separate units
  27. Replies
    22
    Views
    1,206

    Neat. I prefer plastic lineset cover

    Neat. I prefer plastic lineset cover
  28. Pex in pvc sounds ok

    Pex in pvc sounds ok
  29. Replies
    4
    Views
    602

    Get propane torch and fix it. Try not to burn...

    Get propane torch and fix it. Try not to burn down your house, :)
  30. Replies
    8
    Views
    865

    As said by DDC_Dan, they are not bond by NEC...

    As said by DDC_Dan, they are not bond by NEC codes, just like power utility workes bringing power to your house.
  31. Sounds good to me

    Sounds good to me
  32. Replies
    16
    Views
    2,810

    You hired a plumber. Thats a first mistake.

    You hired a plumber. Thats a first mistake.
  33. Not correct about indirect tank

    Not correct about indirect tank
  34. With indirect tank 80,000 btu would be a min. Mod...

    With indirect tank 80,000 btu would be a min. Mod condensing boiler will modulate to your load (with right setup)
  35. Got it online.

    Got it online.
  36. Replies
    11
    Views
    802

    5000uF capacitor on DC side will fix it.

    5000uF capacitor on DC side will fix it.
  37. If you pay for travel expense, then I'll come...

    If you pay for travel expense, then I'll come over and fix it.
  38. Replies
    11
    Views
    802

    Make sure your rectifier has higher amps rating...

    Make sure your rectifier has higher amps rating than your total load ( bigger rectifiers need heatsink)
  39. Replies
    10
    Views
    1,344

    Didn't red tag it?

    Didn't red tag it?
  40. Thread: Reach in cooler

    by zibby
    Replies
    10
    Views
    1,855

    True

    True
  41. Thread: Reach in cooler

    by zibby
    Replies
    10
    Views
    1,855

    If cap tube was clogged, than your low side would...

    If cap tube was clogged, than your low side would go in vacuum. Check your start components, probably ptc is bad.
  42. BS

    BS
  43. Replies
    4
    Views
    851

    proobably wont work. Lots of programms durring...

    proobably wont work. Lots of programms durring installation set path in registry file. Simply comping files will not thell windows where they are.
  44. Replies
    10
    Views
    1,686

    make sure no gas valves are connected to that...

    make sure no gas valves are connected to that pipe. 15' would damage them.
  45. Replies
    10
    Views
    1,686

    test at 3lb for 15 min with no pressure loss. If...

    test at 3lb for 15 min with no pressure loss. If left overnight, temp drop may cause the pressure loss (there is a way to calculate it)
  46. Replies
    31
    Views
    3,943

    it hurts my eyes just to look at it.

    it hurts my eyes just to look at it.
  47. Replies
    8
    Views
    1,051

    get a quickbooks and quickboks mobile (monthly...

    get a quickbooks and quickboks mobile (monthly fee $9.95) it will lewt you enter invoice on the go.
  48. Replies
    7
    Views
    1,756

    Wood and oil in the same chimney?

    Wood and oil in the same chimney?
  49. Replies
    9
    Views
    1,235

    LOL

    LOL
  50. Replies
    7
    Views
    756

    windows 7 look

    windows 7 look
Results 1 to 50 of 266
Page 1 of 6 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event