Search:

Type: Posts; User: chilly123

Page 1 of 4 1 2 3 4

Search: Search took 0.00 seconds.

  1. Replies
    79
    Views
    5,745

    I have been a market tech for the last 27yrs, and...

    I have been a market tech for the last 27yrs, and don't plan on giving up anytime soon.:)
  2. coldkeeper if you have a model # of this unit. my...

    coldkeeper if you have a model # of this unit. my experience with dual temps have been with the m1ge cases. as far as factory setup, don't bet on it:D
  3. Replies
    23
    Views
    1,542

    What frustrates a customer?

    Two things on my end of the world. 1st repeat calls, I seem to gain more customers this way than anything else. 2nd the energy guys that come around every 6mons or so. everytime they make changes to...
  4. Replies
    11
    Views
    1,367

    Were these Bridgeton cases or Mexico ? Its nice...

    Were these Bridgeton cases or Mexico ? Its nice to see I have company on these POS. ever since IR bought hussman the quality is gone.:(
  5. Replies
    11
    Views
    1,367

    Haven't had too many problems with frame heaters,...

    Haven't had too many problems with frame heaters, but have had allot of problems with the doors themselves, not keeping tension. had one store with 35 doors replaced under warranty.
  6. Replies
    2
    Views
    882

    I would certainly go for the drain pan heater. I...

    I would certainly go for the drain pan heater. I have several markets with these cases. All electric defrost, a year after they were installed the drain pans were iceing up. My company has been...
  7. Replies
    6
    Views
    1,367

    groogy1 try getting a little more info in your...

    groogy1 try getting a little more info in your profile. they are DYI's that try this on here. We need to know are you a mechanic, owner. This is our lively hood, DYI's are not taken too kindly here....
  8. Replies
    22
    Views
    2,507

    congrats Mikey on your first year in the markets....

    congrats Mikey on your first year in the markets. my self I have been at it since 1982, and still enjoy it everyday. may you have a long and prosperous career
  9. Replies
    19
    Views
    1,988

    Hmmm sounds very familiar to me. +1

    Hmmm sounds very familiar to me. +1
  10. as slatts stated this info is critical to know....

    as slatts stated this info is critical to know. in addition to check the condition of the contactor or mag starter. if burnt this will cause a single phase condition. if its temp he is concerned...
  11. Well first off what kind of failures is he...

    Well first off what kind of failures is he having? Are these electrical or mechanical? More info is needed. like are these failures on the low temp or midtemp, discharge temps and pressures, suction...
  12. Replies
    13
    Views
    1,607

    Crackertech it just seems like they always want...

    Crackertech it just seems like they always want to take the easy way out. as many times as this subject has come up on this site they just don't get it, as rayr says only two things belong in a...
  13. Thread: Red dye test

    by chilly123
    Replies
    17
    Views
    1,525

    +1

    +1
  14. Replies
    1
    Views
    414

    mikey sq

    try this hussmann model Z reach -in i/c Evap temp -40 Discharge air -10 Btu's per ft 1270, model Z reach -in low temp , evap temp -40 discharge air temp 0 btu's per ft 799. also look at the txv size...
  15. Replies
    16
    Views
    1,252

    DOA's

    A few years back i remember having changed out three caryles o6e comps on a rack. originals fried due to bad contact on the mag starters. Installed all three and went to start them up, open windings...
  16. Replies
    2
    Views
    432

    well there is not much difference than what you...

    well there is not much difference than what you have been working on now. you may see some differences in control set up. There are more self contained units in a c-store. You just have to like...
  17. Replies
    8
    Views
    727

    this was very intuitive on your part to mention...

    this was very intuitive on your part to mention the lack of electric safety's. A blood bank is the last place you EVER want to see some thing go down. this is something that makes the five o clock...
  18. Replies
    22
    Views
    1,568

    What he said, just use the pressure ctrl as a...

    What he said, just use the pressure ctrl as a loss of charge safety. as icemister stated you will get much better control of the box temp as well as a few less headaces:)
  19. Replies
    8
    Views
    1,643

    yotaman16 this is called plausible deny ability,...

    yotaman16 this is called plausible deny ability, standard Hussmann response:rolleyes:
  20. Replies
    18
    Views
    3,482

    May his house be strong! Thanks Andy:)

    May his house be strong! Thanks Andy:)
  21. Replies
    3
    Views
    451

    your doing it now. how long since installation? a...

    your doing it now. how long since installation? a bad install always creates problems like this. R-404 is a great solvent, any junk in the line from install will get to the driers and valves.:( I...
  22. Replies
    10
    Views
    770

    Just as crackertech stated. change oil filters...

    Just as crackertech stated. change oil filters and cores again then retest.
  23. Replies
    18
    Views
    1,197

    floodback

    Jaybee take a look at your case and any walkins that are on the loop first. this will help you narrow it down. the system that is struggling to maintain temp will be the one thats giving you the...
  24. Replies
    21
    Views
    1,544

    sounds like to me they got a great deal. :) and...

    sounds like to me they got a great deal. :) and you also got a great learn experience. myself i have had some fairly large invoices. the last one was 35 hrs on hussmann Rl case lighting:(
  25. Replies
    21
    Views
    1,138

    jaybee if your hitting your low limit at 10 psi,...

    jaybee if your hitting your low limit at 10 psi, you maybe loosing your power through the I/O relays. is comtrol showing any power failures? the line voltage for the solenoids that go through the I/O...
  26. Replies
    21
    Views
    1,138

    since this is a loop system, I am with Ned on...

    since this is a loop system, I am with Ned on this one. if there are llsv how are they powered. for instance i have one store that is loop piping, but the power for the solenoids comes from the rack....
  27. Replies
    17
    Views
    1,163

    Poll: dirtyboy103us

    dirtyboy you have my vote. one just has to go back and read markettechs sticky. in fact it should be mandatory reading when a new person signs on to the site.
  28. Replies
    8
    Views
    708

    this is good to hear frigrader. although is the...

    this is good to hear frigrader. although is the grocery wi your biggest load?. please keep us infomed as to the kwh, i myself would be interested.:cool:
  29. Replies
    6
    Views
    725

    If its a cooler yes there is a problem on its...

    If its a cooler yes there is a problem on its way. If its a freezer the superheat will tell the tale.
  30. Replies
    18
    Views
    1,342

    the co I work for would not even think about...

    the co I work for would not even think about changing gas in a supermarket rack. some of my racks hold around 1800 to 2000 lbs. economically this would not even be feasible. Nothing beats plenty of...
  31. Replies
    5
    Views
    745

    Biblepoet

    As was stated earlier, wide and varying is true. to come up with scenario's with all the wide and varying equipment, I don't think this can be handled with this thread. The lazy and less than trained...
  32. Replies
    23
    Views
    1,385

    yea I got it:D I may be a little slow at times,...

    yea I got it:D I may be a little slow at times, comes with age:p
  33. Replies
    23
    Views
    1,385

    the checks in the mail:D

    the checks in the mail:D
  34. Replies
    22
    Views
    1,626

    Rule#6 never suck on a drain pipe. I watched an...

    Rule#6 never suck on a drain pipe. I watched an apprentice do this one time. :D I didn't stop laughing at him for an hour.
  35. Replies
    23
    Views
    1,385

    Any clues as to how they stay in business? I know...

    Any clues as to how they stay in business? I know around here if you are only selling labor your out of business.:)
  36. Replies
    23
    Views
    1,385

    you mean they actually found somebody to do...

    you mean they actually found somebody to do installs for labor only:eek:
  37. Replies
    23
    Views
    1,385

    Yes its the same here. we also have a...

    Yes its the same here. we also have a refrigeration supply house now selling pipe and insulation to a chain here. My company has told me never to grace their door step, and i will be glad not to. I...
  38. Replies
    19
    Views
    2,286

    how about this calgon np48s from the ice machine

    how about this calgon np48s from the ice machine
  39. Replies
    4
    Views
    647

    james i think jusst about everybody has been...

    james i think jusst about everybody has been caught at this,It happen to me when I worked at the Big H:o
  40. Thread: Wal Mart

    by chilly123
    Replies
    16
    Views
    1,738

    the new racks i have seen are also using caryle...

    the new racks i have seen are also using caryle compound comps on low temp
  41. Thread: Wal Mart

    by chilly123
    Replies
    16
    Views
    1,738

    All the new wally racks here are R-404.

    All the new wally racks here are R-404.
  42. Replies
    17
    Views
    2,364

    congrats markettech, your team did a great job!:D

    congrats markettech, your team did a great job!:D
  43. yes thats as bad as a rotten seafood case. the...

    yes thats as bad as a rotten seafood case. the smell will wear off over time:D kinda makes you wonder if they are trying to do some science experiment:eek:
  44. Replies
    16
    Views
    1,379

    [QUOTE=newbeetech;1724131]never worked on a...

    [QUOTE=newbeetech;1724131]never worked on a margarita machine, but today i did. got lucky found a dirty condanser coil, cleaned and tested/tasted :) well the testing went well but how did it taste?...
  45. Sticky: markettech, brilliant!!!! hats off to ya:)

    markettech, brilliant!!!! hats off to ya:)
  46. Replies
    6
    Views
    688

    well thats 4 + 1 against repair. run as fast as...

    well thats 4 + 1 against repair. run as fast as you can.:D
  47. Replies
    23
    Views
    1,939

    Yes its the same pic as i use in my class, power...

    Yes its the same pic as i use in my class, power point from delmar program.
  48. 520 :eek: first of all if you had that pressure,...

    520 :eek: first of all if you had that pressure, your comp should have dynamited and be setting in the parking lot!. on 408A typical pressures should be 175 to 225 and thats with a full load. you...
  49. Replies
    8
    Views
    999

    have you tried case parts co

    have you tried case parts co
  50. Replies
    339
    Views
    45,935

    What the........??????:confused:

    What the........??????:confused:
Results 1 to 50 of 172