Search:

Type: Posts; User: dfishinfool

Search: Search took 0.00 seconds.

  1. Replies
    11
    Views
    993

    Bought a j&b platinum, no more worries on that...

    Bought a j&b platinum, no more worries on that end
  2. Replies
    11
    Views
    993

    I know that oil level in avacuum pump is checked...

    I know that oil level in avacuum pump is checked when running because if you shut it off(after closing gauge valves) oil would be pulled toward system causing false reading
  3. Replies
    11
    Views
    993

    Pulling vacuum lost power

    :censored: well i waited until we had a beautiful day, was blowing 60 mph a lot this last week and we have a lot of outages on high wind days here in Alaska ,so I assumed ( I know ass out of u and...
  4. Replies
    4
    Views
    1,620

    frosted txv

    I just neede somewhere to bounce my thoughts
  5. Replies
    4
    Views
    1,620

    refer guy

    Well I decided its the txv, pressure drop across the inletscreen,thanks thoughh
  6. Replies
    4
    Views
    1,620

    waterfurnace problems frosted txv

    So I live in alaska ,small town,first time seeing one of these,suction pressure is 25, 55 degrees of superheat ,subcooling is good at 10,head pressure low at265,ewt 33, lwt 32 so td is low,pressure...
  7. Replies
    8
    Views
    4,178

    txv frosted on waterfurnace

    ewo 42 waterfurnace superheat 55 degrees suction presssure 25 ,subcooling 10 degrees,head pressure265, td 1 deg, txv is frosting , ewt 33, unit shuts off on lp , txv is frosted ,thanx in advance
  8. Thread: wayne fh

    by dfishinfool
    Replies
    1
    Views
    375

    wayne fh

    working on a deicer with a wayne fh burning 4 gph, 2 2.00 80deg b nozzles just cant get her to stay running, previous tech replaced control,cad eye,transformer, electrode adjustment to manuf specs...
Results 1 to 8 of 8

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards