Search:

Type: Posts; User: SoFlaDave

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    3
    Views
    353

    The crawl space needs to be completely sealed....

    The crawl space needs to be completely sealed. The RH in there will get into the 90's if the vents aren't closed and there's no vapor barrier. Once it's sealed I would recommend a new DH though just...
  2. maybe it could work but by the time you modify...

    maybe it could work but by the time you modify either the panel or the coil piping to get everything reconnected and support the coil if its horizontally mounted the money saved on the goodman coil...
  3. Replies
    26
    Views
    1,022

    I have a Sruface pro and a windows phone so count...

    I have a Sruface pro and a windows phone so count me in the small market share that wants this!
  4. The compressor is not running when called for and...

    The compressor is not running when called for and it sees no difference between the saturation and suction sensor.

    Edit: Damn too late! but yeah, that will through in a wrench in your diagnostics...
  5. Replies
    16
    Views
    713

    The modules from the Gentech Evergreen motor work...

    The modules from the Gentech Evergreen motor work great too and often are the same price or less than the OEM module alone and available at pretty much every supply house. Match the HP of course....
  6. Thanks Timebuilder, that's the most concise...

    Thanks Timebuilder, that's the most concise description anyone has laid out on that topic. Basically the 180 degree phase difference can only be considered an inversion and not a separate phase...
  7. Replies
    30
    Views
    841

    Drill to the center of the earth and make peace...

    Drill to the center of the earth and make peace with the subterranean lizard people in hopes that they will help us overthrow the Obama administration so we can finally get REAL president?
  8. Replies
    30
    Views
    841

    No the question is, why is this posted in a...

    No the question is, why is this posted in a technical forum?
  9. Apologies to the OP for the derailment. The...

    Apologies to the OP for the derailment. The importance of understanding electrical theory can't be overstated in this trade, so keep it up. Sometimes the difference between a good tech and a great...
  10. If you were to take a voltage reading between...

    If you were to take a voltage reading between capacitor common and the " run" side of the contactor, what would it read?
  11. Other than the obvious function of providing...

    Other than the obvious function of providing power to the the fan and herm terminals there is nothing that can be done on the capacitor common that can't be done from the contactor terminal that the...
  12. Common on the capacitor is nothing more than an...

    Common on the capacitor is nothing more than an extension or hub of the Line voltage that the run windings connect to.
  13. Also despite the terminology, 240v single power...

    Also despite the terminology, 240v single power has 2 distinct phases. I will never understand that, I just accepted it and moved on lol
  14. Common on the cap is common only for the cap. It...

    Common on the cap is common only for the cap. It is completely unrelated to the motor commons.
  15. That is baffling. Does the sound disappear...

    That is baffling. Does the sound disappear immediately after the condenser shuts off continue for a few seconds? It may be originating in the condenser or the air handler. Which thermostat do you...
  16. Just remember that there is no Common winding,...

    Just remember that there is no Common winding, only start and run. The run winding gets supplied with 120v and the common supplies the other line of 120. The start winding is fed voltage that goes...
  17. Replies
    9
    Views
    525

    Where do you live and what temperature are you...

    Where do you live and what temperature are you trying to maintain in the afternoon?
  18. Replies
    70
    Views
    5,820

    Holy sweet baby jesus... They really jammed 4...

    Holy sweet baby jesus... They really jammed 4 rotary comps into this thing! lol I don't know guy's I mean it was cooling, maybe these guy's are the smart ones. That thing is an engineering marvel IMO.
  19. Replies
    22
    Views
    1,010

    Just because the air handler says 3621 in the...

    Just because the air handler says 3621 in the number doesn't mean it's not a 3.5 ton system. The condenser is what determines the bulk of of the system capacity and yours is 3.5 tons.

    Since the...
  20. Replies
    22
    Views
    1,010

    The condenser is 3.5 tons and the air handler is...

    The condenser is 3.5 tons and the air handler is 3 tons nominal but is still a rated match for that condenser.
  21. Replies
    8
    Views
    371

    Do not use the SUPCO start kit it is a cheap 2...

    Do not use the SUPCO start kit it is a cheap 2 wire connection! Install on of the industry standard 3 wire connection kits. Use either the OEM part or a 5-2-1 Start kit. I would probably change the...
  22. I've used pancrete with success a few times....

    I've used pancrete with success a few times. Sealed up some pans on some old floor mount chilled water air handlers and sealed the base pans on some old rtu's that were just trying to get by for a...
  23. If the compressor valves were bad, neither of...

    If the compressor valves were bad, neither of them could pump. It's
    likely an electrical issue and not with the board.
  24. Thread: X13 motors

    by SoFlaDave
    Replies
    23
    Views
    10,058

    My experience is the same and it definitely...

    My experience is the same and it definitely related to moisture as I have had zero issues with the X13 motors in tranes Hyperion series AH and they are not exposed to moisture like standard air...
  25. That is the sad truth about our industry and I...

    That is the sad truth about our industry and I can see the difference in quality after being in the field for just 14 yrs. I had a 30+ yr old GE/ Trane system that the compressor had been miswired...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event