  1. Thread: The new kid

    by theblade
    Replies
    2
    Views
    578

    New Kid

    Here are some suggestions. Do "good, honest work" install/replace/repair if it is needed. Word will get around slowly if you are fair. Word will travel like a wild fire if you are sloppy,...
  2. Replies
    10
    Views
    1,688

    Ask to see the manufacturers installation...

    Ask to see the manufacturers installation instructions. all the limitations, requirements will be in there. I know for a fact on the Trane TUY series, you can have up to 200 ft. of pipe under...
  3. Replies
    9
    Views
    1,898

    Just a reminder. If you are removing an old dry,...

    Just a reminder. If you are removing an old dry, don't use a torch to remove the dryer. Cut the dryer out with a tubing cutter. any moisture or other contanments trapped in the dryer, will bre...
  4. Replies
    20
    Views
    2,057

    One thing to keep in mind, in Jan. 2006 min. seer...

    One thing to keep in mind, in Jan. 2006 min. seer to be manufactured is 13 seer. You may have a real problem trying to match an r-22 coil installed now, with what is available in r-22, two or...
  5. Very important that you find a Rheem Trained...

    Very important that you find a Rheem Trained Tech. quick. Only some one trained and experienced in gas furnaces can evaluate just how dangerious your situtation is. Don't delay. It might be just...
  6. Replies
    1
    Views
    818

    No name, city, address, on air handler. Model #...

    No name, city, address, on air handler. Model # FMB10 36+X3 000 --- coil # FMBXX 36+X3. Need to know if coil will work with heat pump? Has txv, no bypass check valve. Some txv's have by pass ...
  7. Replies
    8
    Views
    1,087

    Magic Chef, (Armstrong) did this in mid 1980's. ...

    Magic Chef, (Armstrong) did this in mid 1980's. 8 seer
    a/c units. Could add selenoid valve near evaporator coil,
    paralell with low voltage to condenser. When condenser stopped at end of...
  8. Replies
    26
    Views
    7,463

    For the time being, it looks as it will be "the"...

    For the time being, it looks as it will be "the" new refrigerant. Will some one develope something later that is better/less costly, safer, who knows? Only time will tell. Properly...
  9. Thread: labor rate

    by theblade
    Replies
    12
    Views
    2,247

    If you are working for some one else, it will be...

    If you are working for some one else, it will be what you are worth to them. How tight the labor market is, how qualified you are, and how you present your self to your employer. There is really...
  10. Replies
    3
    Views
    1,177

    Worked on one or two, called "insider" seems...

    Worked on one or two, called "insider" seems like the one's I worked on were made by a defferent co. Been couple of years. Lot of noise & viberation for inside a home. I think the one's I worked...