Search:

Type: Posts; User: Mike19

Page 1 of 20 1 2 3 4

Search: Search took 0.05 seconds.

  1. Thread: Flag terminals

    by Mike19
    Replies
    14
    Views
    552

    I have this tool from Imperial. It's made for...

    I have this tool from Imperial. It's made for crimping the pins for molex plugs.

    You can also crimp a 90 degree terminal with it (tip of the jaws), it works ok, but not "great" for the 90 degree...
  2. Thread: Flag terminals

    by Mike19
    Replies
    14
    Views
    552

    ^^^ that's what he's talking about. If anyone...

    ^^^ that's what he's talking about.

    If anyone has a good crimper for 90 degree terminals I'm interesting in knowing too.
  3. Thread: Flag terminals

    by Mike19
    Replies
    14
    Views
    552

    596151

    596151
  4. Replies
    21
    Views
    506

    Or an EEV

    Or an EEV
  5. Replies
    70
    Views
    1,404

    I've only ever seen a moisture indicator change...

    I've only ever seen a moisture indicator change color a couple times. It's very rare.

    99.9% of the ones I see are "dry"

    So I don't personally have a need for a moisture indicator.
  6. I feel your pain. I was just working at a...

    I feel your pain. I was just working at a warehouse a couple weeks ago.

    Evaps where at least 20' up, compressors where on platforms 20' off the ground in the loading dock, and the condensers...
  7. Hopefully if your short blows the fuse in three...

    Hopefully if your short blows the fuse in three seconds it shouldn't be too bad to find.

    You may even be able to narrow it down by ohming out wires from the ground.
  8. ZF18 compressor isn't 5 tons. It would only be...

    ZF18 compressor isn't 5 tons. It would only be rated about 18,000btu in a low temp application.

    The dtc valve (discharge temperature control) is what Copeland calls that valve. You can tell when...
  9. Replies
    70
    Views
    1,404

    The last inch on you gauge from 29-30 represents...

    The last inch on you gauge from 29-30 represents 25,400 microns
  10. Replies
    6
    Views
    212

    If it's a smaller digital there is suction,...

    If it's a smaller digital there is suction, discharge, and then the line for the solenoid tees into the discharge and goes back into the top of the compressor.
  11. Thread: Brazing glasses

    by Mike19
    Replies
    8
    Views
    488

    We run into the same problem. We got clipped by...

    We run into the same problem. We got clipped by osha because they wanted us to be wearing the shade 3 welding glasses, but sometimes it's hard to see what you're doing with those glasses on.
  12. Thread: For why?

    by Mike19
    Replies
    2
    Views
    275

    Because none of us want to see that garbage.

    Because none of us want to see that garbage.
  13. Replies
    14
    Views
    522

    What's the model number of the unit?

    What's the model number of the unit?
  14. Make sure your water inlet valve isn't leaking by...

    Make sure your water inlet valve isn't leaking by as well.
  15. Don't start guessing and throwing parts at it. ...

    Don't start guessing and throwing parts at it.

    You can do checks to see if all the parts are operating properly or not. There is no need to be guessing.

    Like pec said, read the manual, and...
  16. Maybe they where talking about construction? ...

    Maybe they where talking about construction?

    Around here construction slows way down during the winter, so there may be some construction people not working a few months out of the year.

    But...
  17. Replies
    21
    Views
    827

    Is everything ok? You seem kind of pouty.

    Is everything ok? You seem kind of pouty.
  18. Thread: Factory Failure

    by Mike19
    Replies
    6
    Views
    1,280

    Trane did that to us. Rooftop came, no...

    Trane did that to us.

    Rooftop came, no refrigerant, a line was fit together but had not been brazed.
  19. Replies
    24
    Views
    762

    If the customer does want to use this box but buy...

    If the customer does want to use this box but buy a new condenser/evap, I would do a detailed load calculation.

    From the sounds of this box, the refrigeration system will have to be generously...
  20. Replies
    24
    Views
    762

    http://boxload.tecumseh.com Has a lot of great...

    http://boxload.tecumseh.com

    Has a lot of great resources.
  21. Replies
    74
    Views
    2,350

    When unit goes into defrost the condenser fan...

    When unit goes into defrost the condenser fan shuts off so the compressor can pump up to 400psi to pump down and shut off.

    No wonder the old compressor went bad, if that's what it had to go...
  22. Replies
    24
    Views
    762

    http://www.heatcraftrpd.com/PDF/Misc/CA-QC.pdf

    http://www.heatcraftrpd.com/PDF/Misc/CA-QC.pdf
  23. Replies
    24
    Views
    762

    http://boxload.tecumseh.com/UnitDataSheetsPDF.aspx

    http://boxload.tecumseh.com/UnitDataSheetsPDF.aspx
  24. Replies
    74
    Views
    2,350

    What on earth is going on here?

    What on earth is going on here?
  25. Replies
    24
    Views
    762

    Your condensing unit has a 1 hp pump, good for...

    Your condensing unit has a 1 hp pump, good for 5,000 btu at -10sst.

    10 by 12 walk in needs at least 8,000btu to achieve a 0 degree box for average usage according to the Heatcraft chart. And that...
  26. Replies
    24
    Views
    762

    Double oh no. Those units can barely handle...

    Double oh no.

    Those units can barely handle an 8x8 box that's brand new.

    I would not bother trying to move the condensing unit. If it can't pull below 30*, moving the condenser to a cooler...
  27. Replies
    24
    Views
    762

    Is this one of those drop in package units that...

    Is this one of those drop in package units that sits on top of the box with a hole cut in the ceiling?
  28. Replies
    9
    Views
    434

    Just wait until you do the Morgue PM and have to...

    Just wait until you do the Morgue PM and have to clean the evaporator, flush the drain, and change door gaskets and drawer seals.....
  29. Replies
    9
    Views
    434

    A couple weeks ago I had a service call for a...

    A couple weeks ago I had a service call for a walk-in cooler and walk-in freezer down.

    I got there and found the cooler at 75 and the freezer at 40.

    I know the smell you speak of. When I...
  30. Replies
    9
    Views
    434

    Is the ceiling caving in and the back of the coil...

    Is the ceiling caving in and the back of the coil is hanging way down?
  31. Replies
    14
    Views
    635

    Yep. That's a common problem. Most customers...

    Yep. That's a common problem.

    Most customers expect a compressor change to cost $150
  32. Replies
    14
    Views
    635

    Most the time it is just a bad compressor. ...

    Most the time it is just a bad compressor.

    But every once in a while I find a bad capacitor, bad relay, or voltage problem.
  33. Replies
    12
    Views
    292

    +1 on checking where your local chapter is. ...

    +1 on checking where your local chapter is.

    The magazine and website and access to the literature are nice.
  34. Replies
    14
    Views
    635

    Get your post count up and apply for the...

    Get your post count up and apply for the professional membership.

    We can talk about technical things more in depth in the professional forums.
  35. Replies
    14
    Views
    635

    I'm surprised the person you where working with...

    I'm surprised the person you where working with doesn't know all this, and you had to call tech support.
  36. Replies
    14
    Views
    635

    They probably meant a universal start kit, like...

    They probably meant a universal start kit, like the Supco 3in1 for example.

    In your situation the compressor is not starting. It sits there and tries to start but is unable to start, so the...
  37. Replies
    74
    Views
    2,350

    3.2 amps or 5.2 amps, either way that isn't very...

    3.2 amps or 5.2 amps, either way that isn't very much.

    It must be some dinky little evap with small heaters, otherwise the op must be measuring amp draw wrong, or something else is effed up.
  38. Replies
    20
    Views
    723

    Well, have you measured how much ice it's been...

    Well, have you measured how much ice it's been putting out to see if it's actually working at its rated capacity?
  39. I'm glad to hear you found a quality company to...

    I'm glad to hear you found a quality company to sort things out.
  40. Replies
    13
    Views
    599

    Is the machine clean? How long is harvest...

    Is the machine clean?

    How long is harvest taking?
  41. Replies
    13
    Views
    599

    +1

    +1
  42. I wonder if the reversing valve is in cooling...

    I wonder if the reversing valve is in cooling mode when deenergized?

    Maybe they could bypass the board and have "y" bring the compressor on as a temporary measure.
  43. Usually when there is a major failure with a...

    Usually when there is a major failure with a small wshp, we will push to just buy a new wshp.

    For what has been spent in parts, I'm sure a new unit would have paid for itself.

    I wonder if...
  44. Replies
    34
    Views
    1,255

    I've had the best luck with the h10.

    I've had the best luck with the h10.
  45. Thread: Well then......

    by Mike19
    Replies
    9
    Views
    587

    Glad nobody was killed or badly injured. That...

    Glad nobody was killed or badly injured.

    That could have ended a lot worse.
  46. Replies
    8
    Views
    574

    We give the owner/manager a "log book". It's a...

    We give the owner/manager a "log book". It's a three ring binder. They keep it somewhere, usually in an office.

    We put our invoices in there, and we write down what we did in the log.

    We also...
  47. Did you take your van to a Dodge dealership or...

    Did you take your van to a Dodge dealership or just to an independent garage?

    We had the squeaky brakes problem with our pro masters, there was a service bulliten out and the Dodge dealership...
  48. Replies
    7
    Views
    1,514

    My machine has been working pretty good It...

    My machine has been working pretty good

    It finally got warm outside here, and it's been keeping the room nice and cool.
  49. Replies
    15
    Views
    795

    I have a tarp

    I have a tarp
  50. Replies
    143
    Views
    3,337

    You need to get the iPhone 6 so you can use your...

    You need to get the iPhone 6 so you can use your Apple Watch with it. lol
Results 1 to 50 of 1000