Search:

Type: Posts; User: jimj

Page 1 of 20 1 2 3 4

Search: Search took 0.07 seconds.

  1. Replies
    1,150
    Views
    123,819

    Come to western Arizona for most of the summer!

    Come to western Arizona for most of the summer!
  2. X2

    X2
  3. The Bay 24 will resolve your issue. You need to...

    The Bay 24 will resolve your issue. You need to remove any pricing in your post, it is not allowed!
  4. Replies
    653
    Views
    48,752

    Thanks Jim, will do.

    Thanks Jim, will do.
  5. Replies
    653
    Views
    48,752

    Jim, I have both the imanifold and iconnect,...

    Jim,
    I have both the imanifold and iconnect, the imanifold is an early version ( serial # 0028) that has had the updated SD card installed. Every time I use it, it tells me there is an update...
  6. Replies
    25
    Views
    929

    You might want to check your temperature...

    You might want to check your temperature instrument in a bowl of ice water to confirm it's calibration before doing your gauge calibration and at the same time do your gauge Low and high side temp...
  7. Thread: Air flow issue

    by jimj
    Replies
    34
    Views
    2,166

    You might want to have duct blaster test done to...

    You might want to have duct blaster test done to check for duct leakage. David R just wrote a great article in one of the trade magazines about this and how air balancing with major duct leakage is...
  8. Add your RA and SA wet bulb temps along with your...

    Add your RA and SA wet bulb temps along with your delivered cfm, outdoor drybulb and you can start to tell a lot.
  9. Replies
    6
    Views
    432

    Yes,lower static means more air flow, more air...

    Yes,lower static means more air flow, more air flow means more HP!
  10. Thread: AEROSEAL

    by jimj
    Replies
    46
    Views
    6,369

    There is no issue what so ever using it with...

    There is no issue what so ever using it with flex. Where ever the leaks are Aeroseal will seal them up to and including 5/8" holes.

    We are a dominant flex area and believe me there are lots and...
  11. Thread: AEROSEAL

    by jimj
    Replies
    46
    Views
    6,369

    Aeroseal system/equipment was developed at...

    Aeroseal system/equipment was developed at Laurence Berkeley Labs by Dr Mark Modera a scientist in there indoor Environment Program.
    The...
  12. Replies
    8
    Views
    638

    Normally each at .03

    Normally each at .03
  13. Replies
    8
    Views
    638

    Don't forget your supply and return registers and...

    Don't forget your supply and return registers and grills, strip heaters, and anything else that will cause a pressure drop.
  14. Replies
    11
    Views
    419

    X2. Well said

    X2. Well said
  15. Replies
    8
    Views
    893

    We have installed a lot of XV20i's and XV18 its...

    We have installed a lot of XV20i's and XV18 its little brother and they have operated flawlessly. The dealer that says they are troublesome does not have a clue. Yes they are both probably more...
  16. Replies
    11
    Views
    419

    If your talking about a RAFG that 1,000 sq inches...

    If your talking about a RAFG that 1,000 sq inches would be a correct minimum number
  17. Replies
    11
    Views
    2,296

    Yup I agree. Hank Rutkowski the author of many...

    Yup I agree. Hank Rutkowski the author of many of the ACCA Manuals ( J,D,S,T,RS P and a lot more) says it his way. For radiant heat to occur, the surface of the skin must "see" the radiating...
  18. Replies
    11
    Views
    2,296

    The first chapter, first page of Manual "RS"...

    The first chapter, first page of Manual "RS" (Comfort , Air Quality, and Efficiency by Design) does a great job of answering your question. But in essence states That when occupant comfort is...
  19. Replies
    7
    Views
    728

    We sell lots and lots of Trane multi stage...

    We sell lots and lots of Trane multi stage equipment and I cant say I have EVER had a customer tell me they regretted the upgrade.
  20. The author of Manual J ( Hank Rutkowski)...

    The author of Manual J ( Hank Rutkowski) recommends that you use average on envelope leakage unless you have done a blowerdoor to show a tighter structure number.
  21. Replies
    52
    Views
    3,661

    Well the idea is that the air that is being...

    Well the idea is that the air that is being removed from the attic is being replaced threw your gable vents and that is partially true. But what is also true is air is being removed from your home...
  22. Replies
    52
    Views
    3,661

    Who convinced you to add an attic fan. It is most...

    Who convinced you to add an attic fan. It is most likely doing much more harm than good. And yes as others have already said it is not undersized.
  23. And you think Trane is not involved in the sticky...

    And you think Trane is not involved in the sticky TXV issue? For that matter so is Amana, Goodman and there parent company Daikin along with Carrier and all its divisions..
  24. Replies
    5
    Views
    610

    Amit Gupta ( Aeroseals CEO) and a group of...

    Amit Gupta ( Aeroseals CEO) and a group of investors purchased Aeroseal from Carrier a few years back. Mr. Gupta held various positions with Carrier Corporation in Indianapolis and with TATA Motors...
  25. Replies
    9
    Views
    880

    You have the type of system that you would be...

    You have the type of system that you would be well advised to set it and forget it. Your using your controller like its a light switch controlling a light and its not.
    Find a temperature that your...
  26. Replies
    5
    Views
    610

    Amit Gupta and Brendan Reid will make I good team...

    Amit Gupta and Brendan Reid will make I good team and I believe this will to a big benefit to both organizations
  27. Replies
    9
    Views
    880

    What speed does your 950 controller say the...

    What speed does your 950 controller say the compressor is running at when you think it is struggling to maintain your comfort? What temp is it set at and what temp is it running at?
  28. Replies
    11
    Views
    842

    X2 If its a Copeland scroll it fits the frozen...

    X2 If its a Copeland scroll it fits the frozen coil syndrome. It will usually show up after a few weeks of operation. Not saying your system is wired correctly, it sounds like it is not. But that's...
  29. Replies
    9
    Views
    854

    LOL Trane produced there first inverter system...

    LOL Trane produced there first inverter system in 1987 the XV1500.There still are many operating in my area where 120* days are common.
  30. Thread: XL20i noise

    by jimj
    Replies
    40
    Views
    3,283

    Zone one is right at 100% and is less than 1/2...

    Zone one is right at 100% and is less than 1/2 degree from thermostat setting. Zone 2 is at 29% and .3 degrees from set point. Yes your TESP is .31 which is nothing even close to its capability.
  31. Replies
    22
    Views
    1,750

    I would have them do the install correctly, and...

    I would have them do the install correctly, and that starts with a manual J for system sizing, manual S for unit selection! And then manual D for your duct system sizing and complete a duct leakage...
  32. Replies
    3
    Views
    558

    Dirty air filters = less airflow= colder SADB...

    Dirty air filters = less airflow= colder SADB temp. Read PHM's post again, there's your answer!
  33. Replies
    80
    Views
    4,879

    X2

    X2
  34. Replies
    80
    Views
    4,879

    Ed did they teach you about super heat and sub...

    Ed did they teach you about super heat and sub cooling at tech school?
  35. Replies
    16
    Views
    1,937

    Yes I have one, for the price its really a pretty...

    Yes I have one, for the price its really a pretty cool tool. Is it as good as my TSI Fluke? No, but sure is a lot less expensive. Its a great tool for me to have in my pocket when doing estimates and...
  36. Replies
    27
    Views
    1,314

    There's more to maintaining comfort in a room...

    There's more to maintaining comfort in a room than heating and cooling (meaning air flow). Has the insulation been looked at? Are there interior door closures at certain times of the day causing...
  37. Replies
    15
    Views
    1,324

    Believe me there is a lot more cost involved in...

    Believe me there is a lot more cost involved in what you got than the cost of the part. No that is a very fair price.
    You might also want to read the rules here! No pricing is allowed.
  38. Very ,very doubtful the city will have any...

    Very ,very doubtful the city will have any information that will help with your issue. But your local utility may very likely have a duct seal/test program that will help you. As said about a Duct...
  39. Thread: Goodman

    by jimj
    Replies
    3
    Views
    582

    Goodman and its parent company (Daikin) are the...

    Goodman and its parent company (Daikin) are the largest manufacturer of residential air conditioning in the world, so they must be doing something right.
  40. I think at the rate your going your going to be...

    I think at the rate your going your going to be changing a lot of parts. I'm guessing your Trane guy from the supplier is a parts guy and not a tech? A tech that knows what he is doing will find your...
  41. The XL19i was the top of the line Trane system...

    The XL19i was the top of the line Trane system when it was made and a little more sophisticated than its single stage brothers. You have a great unit, I really would advise you to fine a Trane dealer...
  42. Thread: c.f.m. per ton

    by jimj
    Replies
    3
    Views
    1,616

    Its really based on your SHR ( sensible heat...

    Its really based on your SHR ( sensible heat ratio). In Phoenix ( Arid climate) with a high SHR your 450 cfm per ton would be good, however in Miami ( Humid Climate) with a low SHR you would be...
  43. Thread: Made in USA

    by jimj
    Replies
    66
    Views
    4,173

    Daikin ( parent company of Goodman) inverter mini...

    Daikin ( parent company of Goodman) inverter mini splits will begin production in the USA in the next couple of months.
  44. Replies
    7
    Views
    500

    Yes based on outdoor unit tonnage,...

    Yes based on outdoor unit tonnage, but......................

    Truth be told it should be based on your SHR ( sensible heat ratio) from your Manual J, S and manufacturer extended ratings.
  45. Replies
    2
    Views
    348

    First off anyone sizing by square footage, be it...

    First off anyone sizing by square footage, be it 400 or 600 should not be considered. You need someone that will do a manual J for your job for proper sizing and then match it to the manufactures...
  46. And some times if you do it just right you can...

    And some times if you do it just right you can even have a little fire to warm yourself. LOL
  47. The increase in AIR FLOW would increase your...

    The increase in AIR FLOW would increase your supply air temps at your supply register.



    You most likely are closer to your proper air temps now than before when moving only 1000 cfm on a 3 1/2...
  48. LOL :payattention:

    LOL :payattention:
  49. Replies
    1,150
    Views
    123,819

    Jim will you be filling back orders first? Got...

    Jim will you be filling back orders first? Got notice of the simm card being shipped but nothing on my June order of the wireless probes.
  50. Replies
    34
    Views
    4,452

    X2

    X2
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4