  1. Replies
    29
    Views
    4,407

    My aunt still has one of those bathroom heaters,...

    My aunt still has one of those bathroom heaters, and uses it. She lights it to take chill out of the room then turns it off and takes her bath or shower. She has lived in that house 60 years and will...
  2. Thread: Lawnmowers

    by Wirenut
    Replies
    38
    Views
    3,015

    I have a John Deer self propelled front wheel...

    I have a John Deer self propelled front wheel drive. Like the way it will adjust to your walking speed and isn't too cumbersome to use as a trim mower when locked out of self propelled mode. Brigs...
  3. Replies
    45
    Views
    3,628

    I use a flow regulator mfg by uniweld. A lot of...

    I use a flow regulator mfg by uniweld. A lot of brazing can be done with a little nitrogen. As someone already mentioned, do not try to braze with any pressure on the system. If anyone thinks...
  4. 10 year old Lennox 2 stage furnace 13 seer AC, no...

    10 year old Lennox 2 stage furnace 13 seer AC, no problems yet. I replaced the Invesys thermostat with a new vision pro and outdoor sensor. Now I don't need to find my glasses to check the outdoor...
  5. Replies
    218
    Views
    18,030

    That install belongs on the wall of shame! You...

    That install belongs on the wall of shame! You should be concerned about the equipment even if all of the ductwork and poor installation issues are corrected. I would be willing to bet the system...
  6. Replies
    15
    Views
    1,181

    I wouldn't make any changes in the furnace...

    I wouldn't make any changes in the furnace installation yourself. I do know that what you are considering isn't approved by the mfg. The venting and combustion air intake of any furnace is covered...
  7. Replies
    34
    Views
    2,282

    :confused:I would never pump down any system, new...

    :confused:I would never pump down any system, new or old junker without a set of gauges on the unit! Can't figure why any service technician would tell a Handy homeowner to do such a thing. A ten min...
  8. Replies
    60
    Views
    3,946

    Matt, glad it all worked out for you...sorry you...

    Matt, glad it all worked out for you...sorry you had such a experience!! I don't support DIY repairs for many reasons, safety being at top of list. Couldn't be any more unsafe than the guys working...
  9. Replies
    3
    Views
    378

    That is probably going to cause problems with...

    That is probably going to cause problems with room overheating during the heating season. The combined heat from the furnace and the electronic equipment will make it real toasty in there. The room...
  10. Replies
    499
    Views
    31,787

    I am a HVAC service technician, who has had a two...

    I am a HVAC service technician, who has had a two stage Lennox in my home for 8 years. Don't have much time or desire to check measure or fool with the furnace in my own home:D I do pay attention to...
  11. Replies
    8
    Views
    2,941

    Noise? Possibly a little more noise than the old...

    Noise? Possibly a little more noise than the old Reznor it replaced. My heater is located between two rooms and the old reznor was just low enough to bump head on. The hot dawg is only 13 inches from...
  12. If you are talking about the honeywell smart...

    If you are talking about the honeywell smart valve with a little green led on it a steady light means the valve has failed. In any case you can't fix the problem yourself. Make the call to have it...
  13. Replies
    8
    Views
    2,941

    You need to have It looked at by a service...

    You need to have It looked at by a service technician. I have the same style heater in my garage a 30000 btu unit,it works great, no problems at all. Agree the problem may be venting related or...
  14. Replies
    14
    Views
    1,034

    I would question the contractor who told you to...

    I would question the contractor who told you to connect the black wire to anything. You should NOT make any wire changes to the system! The company who installed the board should be the one to check...
  15. Replies
    14
    Views
    1,499

    If the valve on your old lennox had pilot button...

    If the valve on your old lennox had pilot button on the left side and a separate pilot on and off valve on the top, it is a slow open and closing valve. The G8 and 12 furnaces may encounter pilot...
  16. Replies
    14
    Views
    1,499

    I have seen them on some very old equipment,...

    I have seen them on some very old equipment, Essex valve with brown cover , they had a bimetal actuator with heater coil. They were slow opening and closing.
  17. Replies
    14
    Views
    2,419

    Lady said she was going to have someone to look...

    Lady said she was going to have someone to look at system, don't see how she has violated any rule on here;) I would not use the unit or shut gas off to the furnace until you can have the system...
  18. Replies
    14
    Views
    2,419

    L

    L
  19. Replies
    26
    Views
    2,415

    Ok guys tomorrow I will heat a jug of 410 until...

    Ok guys tomorrow I will heat a jug of 410 until it just about floats, then it will be much easier to carry to roof. I will update on how it goes.:D
  20. Replies
    19
    Views
    1,193

    Fan assisted furnaces vented into old unlined...

    Fan assisted furnaces vented into old unlined chimneys are not good and CAN cause the problem you are experiencing. Hope you are able to get problem resolved soon.
  21. Replies
    61
    Views
    6,868

    I changed a compressor in one of those last...

    I changed a compressor in one of those last month! The air handler was a small unit and would require some major work on the rental apartment to change the indoor part of the system. It was a waste...
  22. Replies
    61
    Views
    6,868

    I changed a compressor in one of those last...

    I changed a compressor in one of those last month! The air handler was a small unit and would require major work on the rental apartment to change the indoor part of the system. It was a waste of...
  23. Replies
    7
    Views
    2,100

    As a matter of fact they DO, most storage tank...

    As a matter of fact they DO, most storage tank type natural draft water heater's use standing pilots, you propane unit probably has a pizo ignitor button used to spark light the STANDING pilot. A...
  24. Replies
    7
    Views
    2,100

    I have used the tjernlund side wall vent kit with...

    I have used the tjernlund side wall vent kit with good results, a pilot saver kit should be installed otherwise the pilot will go out whenever the power fails, even for a few seconds. This isn NOT a...
  25. I would have the contractor recheck the vent...

    I would have the contractor recheck the vent termination. In the installation manual you should find the correct vent terminations for your furnace. I am not sure the pictured termation is correct....