Search:

Type: Posts; User: PBW28

Search: Search took 0.01 seconds.

  1. Replies
    2
    Views
    270

    Thanks Ralph..appreciated. Cheers PBW

    Thanks Ralph..appreciated.
    Cheers
    PBW
  2. Replies
    2
    Views
    270

    XL500 and XL 50 Current Products?

    Hi there,

    Can anyone out there tell me if the XL 500 and XL50 (LON) are current products..as in still sold by Honeywell? If they are not does anyone know when they became obsolete?

    Thanks for...
  3. Excel 800 Schedule adjustment via BACnet with EBI R410?

    Hi There,

    Wondering if anyone can help me out here... There is a job with EBI R410 server, Excel 8000 controllers communicating via a LON Point server to the EBI. There is also a BACnet Point...
  4. Thread: SEIBE MN-MSI

    by PBW28
    Replies
    3
    Views
    1,178

    You wil also need an MN -CIM serial adapter as...

    You wil also need an MN -CIM serial adapter as well as the MNET-CI. But depending what the integration device is GCM/UNC you may be able to see all the bits you want any way from the device objects...
  5. Thread: SNMP Driver

    by PBW28
    Replies
    1
    Views
    369

    SNMP Driver

    Hi All,

    Anyone had any experience with an SNMP MIB from APC ? Iam looking at some UPS units and some Computer Room PAC's.

    I am parsing the file with Mibble and getting some Integer32 syntax...
  6. Replies
    10
    Views
    1,618

    Thanks for the feeback Orion. This helps a...

    Thanks for the feeback Orion.

    This helps a lot. I was sure the Trend systems I had seen in the past were significantly more responsive.

    The reprogram ability sounds like a possibility our...
  7. Replies
    4
    Views
    1,282

    Thanks for the info Keith. This place is a...

    Thanks for the info Keith.

    This place is a multi tower complex and all in all about 6000 IQL VAVs.

    The driver we are looking are testing presently is the ISOFT driver and it is having a few...
  8. Replies
    10
    Views
    1,618

    Hi Orion, Thanks for the advice there are...

    Hi Orion,

    Thanks for the advice there are around 2,500 IQL's in the building so when they lose one they lose about 6-8 floors. However even this is a bit dodgy.

    Is it possible to alter the...
  9. Replies
    5
    Views
    1,811

    This is an old thread now but I am happy to say...

    This is an old thread now but I am happy to say we got the Honeywell EBI interface working in the end.

    It was afiar bit of work getting the big H to agree to our points list and supply them as...
  10. Replies
    4
    Views
    1,282

    Thanks Keith, Yep realise I need the LCi so...

    Thanks Keith,
    Yep realise I need the LCi so thats covered. Can See the controllers natively no probs via the JACE. Worked out the Knobs and Switches etc for the interface. We have the IQL VAV which...
  11. Replies
    10
    Views
    1,618

    Trend Controls 3XTEND

    Hi There,

    Hoping some of the Trend experts might be able to help out !!

    Is there a recommended number of LON devices to hang off a 3XTEND? Like anything I imagine there is a maximum number of...
  12. Replies
    4
    Views
    1,282

    TREND IQL VAV controllers

    Hi There,
    Has anyone succesfully integrated Trend IQL VAV without The 3XTEND EINC L or equivalent and still been able to implement SET across the LON bus?

    It appears that the IQL VAV's are using...
  13. Replies
    5
    Views
    1,811

    Honeywell EBI as a BACNet Server

    Hi There has anyone had any experience setting up an EBI as a BACNET server? We are doing an Integration and want to use the EBI to serve some XL10/XL500 points....quite a few actually. Its an R310...
  14. Thread: pneumatics

    by PBW28
    Replies
    13
    Views
    984

    WPT

    Hey kontrolphreak, That pneumatic wireless retro stat looks interresting have you ever used any? Do they work well? I was a little confused about the Hub that goes direct BACNet or do they mean the...
  15. Thread: pneumatics

    by PBW28
    Replies
    13
    Views
    984

    The Golden Rule

    as you probably know if the pneumatics are going to stay for a while the golden rule with pnuematics is a clean dry oil free air supply. If this is not the case now and there is an abundance of oil...
  16. Replies
    10
    Views
    1,044

    Thanks Gnomethang

    Thanks for that Gnome thang,

    For sure the guys I have see driving the system see athat set is a bit of an issue. Reassuring I am at least looking up the write tree with the traffic issues. Thanks...
  17. Replies
    8
    Views
    600

    Home is the issue I think....

    I am reasonably sure that using XP home is the issue.
    Remote Desktop and Internet Information Services are not loaded on Home. Intellimirror which hosts a plethora of change and config services is...
  18. Replies
    10
    Views
    1,044

    Thanks loopy

    Thanks Loopy it does help a lot. I contacted Trend via the website and got a Letterheaded repli in just an hour or two. Great service I must say. Yes we have literally hundreds installed over a...
  19. Replies
    10
    Views
    1,044

    Trend Beasties

    Thanks orion they are a beast thats for sure but tough and durable I must say thanks for the feedback
  20. Replies
    8
    Views
    600

    Ididnt think R2 ran properly on Home....think...

    Ididnt think R2 ran properly on Home....think there were some services issues...anyway if it works good luck.
  21. Replies
    10
    Views
    1,044

    Who Knows about TREND Controls...the brand..

    Hi there...I was wondering if there is anyone out there who is a TREND controls dealer. I am trying to find out if the IQ251 controller is still current and if so how long has it got to run in its...
  22. Replies
    4
    Views
    489

    Home plug

    Thanks jd51873, but maybe I was not clear I think scrooloose is on the wavelength.
    Home Plug ia a technology where by you use the power wiring as a comms LAN an improvement on the old power line...
  23. Replies
    4
    Views
    489

    Home Plug??? Who can tell me....

    Hello All,

    Was thinking (for a change) Can anyone tell me if there are any 24Vac "Home Plug" devices on the market I have an old Honeywell R-Bus installation to deal with for a retro, and see...
  24. Replies
    3
    Views
    527

    Thanks Fella's will investigate further. PBW

    Thanks Fella's will investigate further.
    PBW
  25. Replies
    3
    Views
    527

    Need some help with CH530

    Hi there,
    I was wondering if anyone can tell me whether the CH530 comes standard with the Trane Comm 4 protocol?

    I have 2 separate Trane installations 1 with 4 off RTAC machines (2 x250's and 2 x...
Results 1 to 25 of 25