    Alerton IBEX Tux calibration question

    I have a few TX-VAV controllers that are not reading properly.
    I pulled both tubes off of the controller and are still reading 600-900 cfms on some of these

    I know I can do a calibration with...
  2. Trane Tracer L / Varitrac problems with TED600 voyager RTU issues (erratic behavior)

    I have a EMFT000AAC02100 that I hyperterm into that has been running several ucm's for VAV/FTUs and 2 TED600 voyager rooftop units.

    Part # Tracer L
    Date - 2397 "1997"

    I have been getting...
  3. Replies
    8
    Views
    1,048

    Correct me if Im wrong but this pressure...

    Correct me if Im wrong but this pressure controller is not a solid state control. This one has two sets of contacts and has a drive open circuit and drive closed circuit. Completely mechanical.
    ...
  4. Replies
    8
    Views
    1,048

    I have not at this point. I was hoping to have...

    I have not at this point. I was hoping to have some creative yet less expensive options from all of the guys on here that may have ran into this one.

    I do believe you may be right about this.
    ...
  5. Replies
    8
    Views
    1,048

    I suppose erratic static is a better description...

    I suppose erratic static is a better description for the term. They aren't sticking though.

    They start to move and then get to a point and due to the slack in these bushings they make it to a...
  6. Replies
    8
    Views
    1,048

    CARRIER - Inlet Guide Vane problems

    Model 48DKD064--A series 600SM


    I have a set of inlet guide vanes that have a series of white plastic bushings (11 per side) on the outer ring of the assembly that hold the armature which turn...
  7. Replies
    1
    Views
    605

    KMC digital designers guide

    I read on a seperate post on this site that there was a kmc sp-022 which is the digital designers guide and the site has no file assigned to the link. Like it used to be a downloadable file and no...
  8. Replies
    2
    Views
    1,010

    Alerton IBEX woes !!!!!!

    Ive got a building with the soon to be extinct ibex system. Does anyone know if there is still any training on this?
    Is there any way to integrate the VAV/FTU controllers over to a bacnet system?...
  9. Replies
    174
    Views
    23,010

    PH i would really be interested in talking to you...

    PH i would really be interested in talking to you if you have a chance about some ibex issues i cant get resolved. Unfortunately our project manager outsourced this project to another local outfit...
  10. Thread: York YCAR IOM

    by Hoopstir
    Replies
    10
    Views
    1,197

    That is clearly the Installation manual that I...

    That is clearly the Installation manual that I was looking for however the current unit I am working on is a remote condensing unit and is hooked to a chiller bundle located inside the building
    This...
  11. Replies
    7
    Views
    1,426

    Non condensibles only show a high head if the...

    Non condensibles only show a high head if the freon is moving properly. You said you have a temp drop across the drier so there is a restriction. Period. Your line is getting cooler because the...
  12. Thread: York YCAR IOM

    by Hoopstir
    Replies
    10
    Views
    1,197

    Also it appears that this compressor is not going...

    Also it appears that this compressor is not going to be easy to find. Most likely going to need to be rebuilt. Copeland has been pushing the universal screws and am kinda curious if anyone has...
  13. Thread: York YCAR IOM

    by Hoopstir
    Replies
    10
    Views
    1,197

    Well I have a compressor that completely...

    Well I have a compressor that completely scrambled on this unit and one just like it. Both were circuit #1. I noticed neither unit have much volume in the chilled water loop and one is a packaged...
  14. Thread: York YCAR IOM

    by Hoopstir
    Replies
    10
    Views
    1,197

    York YCAR IOM

    I have googled and checked absolutely every where to find an IOM for a york YCAR0200SC46PAA chiller and have not been able to find anything other than a parts break down manual for this thing. I...
  15. Brand new Marley Tower has MUDDY RUST that wont go away

    I installed a 2 cell marley tower and it was sitting in a storage yard for awhile and I believe its full of gravel dust. However the rust in the pipe has turned it a cool shade of orange. This...
  16. Replies
    9
    Views
    2,733

    Start up spreadsheets

    I was interested in finding out if any of you have any Factory startup (excel spreadsheets) or have made your own?

    I would be interested in finding some of the major commercial brand startups but...
  17. Thread: WTF 2

    by Hoopstir
    Replies
    41
    Views
    3,717

    Hmmm not a rezzy at all Pic is hard to tell. ...

    Hmmm not a rezzy at all

    Pic is hard to tell. Equipment looks proper. If thats the door on the right there is no louvers to give this thing some life.

    If the crapper gets used as often as mine...
  18. SEMCO energy recovery wheel (motor problem)

    Never had one of these things separated from the gearbox but it does look as if the motor (alone) has been replaced before and its bad again.

    Has anyone done this!!

    I was at a building today...
  19. The piping problems i referred to was the lack of...

    The piping problems i referred to was the lack of a storage tank. However the customer isnt willing to spend that kind of money since there has not been a catastrophic failure to this point.
    ...
  20. Replies
    2
    Views
    797

    Thigh just got lucky

    Well after shucking the skin and bones off of about 5 lbs of chicken thighs the old lady picked up yesterday.

    I went to the cupboard for the trusty jamaican jerk marinade and nowhere to be found. ...
  21. This may sound crazy (soft start on a recip compressor)

    I wanted to run something by everyone and see if this seems to be possible.

    I have a customer that has a York chiller on a building that (lets put it this way) Has a.

    "Not so good setup" with...
  22. Replies
    21
    Views
    1,197

    Im not sure if i am more disturbed at the fact...

    Im not sure if i am more disturbed at the fact that this smack pissed on the coil or that you found it comical.

    What a tool that guy was (not a leak detector either)

    Seriously I believe his...
  23. Replies
    12
    Views
    881

    Well I happen to be one of the newbie tech years...

    Well I happen to be one of the newbie tech years ago that worked for a contractor that insisted that we use nothing but R22 in everything that we worked on.

    I was extremely upset by the newfound...
  24. Are there any good (Generic) Commercial startup sheets or spreadsheets ????

    Well after countless debates on what information we need to be keepin track of I dont believe I have found anything that really seems to be a good answer to a good generic startup sheet.

    I was...
  25. Thread: dinosaur

    by Hoopstir
    Replies
    16
    Views
    3,274

    Thats clearly a gem However, I have been...

    Thats clearly a gem

    However, I have been reading posts all morning and I got a huge chuckle out of the

    Asbestopus comment.

    Thats a classic!!!

    Kudos T527ed
Results 1 to 25 of 43
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event