Search:

Type: Posts; User: Ricky Dale

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. RUNDAWG: I need your wisdom on a Trane actuator motor operation.

    Hello: Forum

    Rundawg, I have a couple questions on the operation of Trane actuator motors installed on a four pipe Trane fan coil unit.
    The actuator motor is...
  2. Replies
    0
    Views
    252

    cycling of fan coil blower motor

    From time to time I work on four pipe Trane fan coil units. They are controlled by Trane's tracer summit software. My question is what cycles the blower motor? The best I can figure is when the space...
  3. Thank you mason

    Thank you mason
  4. Replies
    8
    Views
    547

    The spark module is integrated into the board. ...

    The spark module is integrated into the board. Situation is understood my thanks to mason and a big thanks to rundawg.
  5. Order of safety checks Trane package gas.

    I've gotten conflicting information concerning the order in which the roll out and limit switch are checked to be closed when the there is a call for heat. one person stated the pressure, roll out...
  6. Replies
    8
    Views
    547

    Right you just jarred my brain safetys are...

    Right you just jarred my brain safetys are checked first. Thanks the ignition board is bad. I appreciate you.
  7. Replies
    8
    Views
    547

    My mistake yes the limit switch location. Once I...

    My mistake yes the limit switch location. Once I can confirm the limit switch location and that it is closed i'll know if the ignition board is faulty. The connection are made from the ignitor...
  8. Replies
    8
    Views
    547

    L

    L
  9. Replies
    8
    Views
    547

    L

    L
  10. Replies
    0
    Views
    199

    Trane XL 1600 package gas.

    I have a Trane XL 1600 to look at Monday. So far I've gotten the tech. on the job to confirm the inducer motor runs then the pressure switch closes and that's there is ctrl. voltage between w1 and...
  11. Replies
    8
    Views
    547

    limit rollout switch

    Hello: I have a call to go to on a Trane XL 1600 package gas. I'm short on time with this and would like to know exactly where the limit rollout switch is located. So far I've been told the inducer...
  12. Replies
    75
    Views
    40,362

    Sticky: I didn't ask if it was rocket science i asked...

    I didn't ask if it was rocket science i asked wher is the additions tab.
  13. Replies
    75
    Views
    40,362

    Sticky: additions tab

    where do i find the additions TAB?
  14. Replies
    75
    Views
    40,362

    Sticky: I am so glad to see that members must conduct...

    I am so glad to see that members must conduct themselves verbally as professionals. Thank you very much hvac-talk.
  15. Replies
    35
    Views
    3,603

    answers for heat pum question in Pa.

    A heat pump isn't recommended for you all up there unless it has a new 16 seer plus rating. You all get to cold of weather. make sure no water can drip on your coils and make sure you have drains...
  16. Replies
    18
    Views
    5,948

    suggestion to intermitting defrost problem

    Your defrost board may have an issue which hasn't totally failed.
  17. Replies
    15
    Views
    1,096

    Your sister should have a 5 ton unit. If the...

    Your sister should have a 5 ton unit. If the service man charged me $ for a service call and to add refrigrant, i would tell him to reclaim it and put the $ towards a new unit.
  18. Replies
    10
    Views
    2,477

    This split unit is on top of a high school and...

    This split unit is on top of a high school and the personnel before me i know didn't clean any RTU coils. First stage works fine in heat as well as cool mode. Second stage will frost over on both...
  19. Replies
    10
    Views
    2,477

    I have a 2 stage, 4 compressor Trane split water...

    I have a 2 stage, 4 compressor Trane split water source heat pump that has a problem in the 2nd stage. My liquid line is frosting on both sides of my filter/dryer. I've changed the power head. The...
  20. Replies
    102
    Views
    13,596

    Happy new year! I appreciate the assistance you...

    Happy new year! I appreciate the assistance you all have given me in 09 and look forward to being a more knowledgeable therefore better technician by you alls help this year. Ricky Dale.
  21. Replies
    102
    Views
    13,596

    aren't complimented enough.

    aren't complimented enough.
  22. Replies
    102
    Views
    13,596

    Mr: jpsmith: Thank you i agree totally. People...

    Mr: jpsmith: Thank you i agree totally. People who speak in a negative tone are not happy people and create a negative environment. I personally think they are complimented enough by people...
  23. Replies
    102
    Views
    13,596

    I've bent the ears on a ballists 90 degrees when...

    I've bent the ears on a ballists 90 degrees when 208 joilted me. I don't want any more than that. I've been working around 477 volts for years and never been hit. I respect it very much. We have...
  24. Replies
    102
    Views
    13,596

    Thanks

    Yes you have
    Thank you
  25. Replies
    102
    Views
    13,596

    I work in the field m-f 6:30 to 3 pm. I also have...

    I work in the field m-f 6:30 to 3 pm. I also have my own licensed business. I keep a a800 plus high school operating and well as changing out household units and troubleshooting them. Also some duct...