Search:

Type: Posts; User: thermofridge

Page 1 of 13 1 2 3 4

Search: Search took 0.01 seconds.

  1. Guys, all of this effort and time spent on...

    Guys, all of this effort and time spent on learning something new instead of laughing at this poor guy and maybe we all become better techs. Just saying.
  2. I service 9 supermarkets. Refrigeration and HVAC....

    I service 9 supermarkets. Refrigeration and HVAC. Plus a wide range of smaller commercial accounts. It has been my experience that a new, young manager will want to be hands on with his racks. I will...
  3. Why did you recharge it? Was there a leak? Did...

    Why did you recharge it? Was there a leak? Did you fix it? Who cares about the valve, is the cooler working?
  4. Replies
    133
    Views
    4,702

    When you start to stack customers like that, you...

    When you start to stack customers like that, you know you are doing fine. That is what keeps me going. Never be satisfied with what someone tells you, go find out for yourself. Everyone does things...
  5. Replies
    133
    Views
    4,702

    Sometimes a line set is long enough and receiver...

    Sometimes a line set is long enough and receiver small enough that the charge will not fit into the receiver when the receiver liquid line is seated closed. VIP99, if the solenoid is near the evap....
  6. Replies
    52
    Views
    5,074

    Hisser- big leak Weeper- small leak Crank it...

    Hisser- big leak
    Weeper- small leak
    Crank it up- time to get to work/ make some money
    Blow the b*tch- turn on the nitro flow
    Gas-freon
  7. Why is the air coming in and not going out? Is it...

    Why is the air coming in and not going out? Is it always the same or does it get worse when it is colder?
    Ask yourself this question. Why is the air entering my house through my kitchen exhaust...
  8. Replies
    39
    Views
    2,315

    When you do find a leak, don't assume you are...

    When you do find a leak, don't assume you are done. JP's method is good and should be followed to the end whether you find a leak before you get there or not. By being thorough, we have drastically...
  9. Replies
    23
    Views
    3,564

    It is really not that bad carrying a Ridgid 1210...

    It is really not that bad carrying a Ridgid 1210 threader around. If I have my choice, I will black pipe every inch of the gas piping. When I must use CSST, I never bring it down to the appliance. I...
  10. Replies
    41
    Views
    2,332

    I must think differently because I would just...

    I must think differently because I would just pull the cap tube and put in an AXV. Done it many times with no problems. One day I was thinking and thought why not dump the POE and add MO? Did that...
  11. Replies
    18
    Views
    807

    http://www.packless.com/

    http://www.packless.com/
  12. Replies
    9
    Views
    1,035

    The flame sensor needs to be replaced annually....

    The flame sensor needs to be replaced annually. That will fix your problem.
  13. Replies
    67
    Views
    3,202

    I once worked on an upright freezer that had a...

    I once worked on an upright freezer that had a second fan on the other side of the compressor that started and blew the opposite direction in off cycle and defrost. Cant remember the brand but it was...
  14. Replies
    12
    Views
    3,474

    One issue we have seen is cracks on the discharge...

    One issue we have seen is cracks on the discharge header developing. It is always the center compressor(5 comp. Hill racks) Have had 3 racks flat on gas just a few weeks after conversion. Engineers...
  15. Replies
    47
    Views
    3,508

    R-22, R404a, R407a,R410a, vac pump, reclaimer,...

    R-22, R404a, R407a,R410a, vac pump, reclaimer, reclaim drum, 2 gauge sets, torch, silfos, pipe cutter, reamer, nitrogen tank, flow meter, gear wrenches, sockets, crescent wrenches, nut drivers, allen...
  16. A 3 zone minisplit would be ideal. The basement...

    A 3 zone minisplit would be ideal. The basement would benefit from the inverter technology for max dehumidification. The other 2 floors would work great as you have described.
  17. I have learned alot about log homes. 1. Never use...

    I have learned alot about log homes. 1. Never use the R-values provided by the log manufacturers. 2. Assume the logs will not be sealed correctly. 3. Run like hell.
  18. Replies
    3
    Views
    402

    Increase the R-value in the bathroom and make...

    Increase the R-value in the bathroom and make sure your vapor barrier is right. Tie the bath fan to the office lights and install a transfer grill from the main floor or bring in outside air to the...
  19. Thread: Hunting

    by thermofridge
    Replies
    7
    Views
    490

    What controller?

    What controller?
  20. Replies
    3
    Views
    402

    Why wouldn't you just go ductless?

    Why wouldn't you just go ductless?
  21. Replies
    25
    Views
    1,952

    So many times i see guys panic when they see the...

    So many times i see guys panic when they see the suction line freeze. You need to trust your instruments. Set your superheat at the bulb, check it at the compressor and realize that the ice is from...
  22. Replies
    3
    Views
    368

    And it is quieter than the old one, right? So,...

    And it is quieter than the old one, right? So, what was the problem?
  23. Replies
    35
    Views
    4,055

    Looks like you need the TH8321 tstat. Look at...

    Looks like you need the TH8321 tstat. Look at page 72-76
    https://customer.honeywell.com/resources/Techlit/TechLitDocuments/68-0000s/68-0312.pdf
  24. Replies
    35
    Views
    4,055

    One of our suppliers is haveing a class on these...

    One of our suppliers is haveing a class on these new stats tomorrow at 3PM. I installed 3 the other day with remote sensors. I had to search pretty hard to find the setting to control 2nd stage cool....
  25. Replies
    7
    Views
    478

    It won't hurt the compressor to try. If the...

    It won't hurt the compressor to try. If the condensor won't hold the charge, the internal bypass will open in the compressor. You will hear it and the suction pressure will not drop.
Results 1 to 25 of 313
Page 1 of 13 1 2 3 4