  1. Replies
    26
    Views
    4,520

    Well, any micron gauge is better than no micron...

    Well, any micron gauge is better than no micron gauge.

    But I would've spent the extra money on the accutools bluvac. It's an amazing piece of equipment. Just my opinion.
  2. Replies
    8
    Views
    709

    The only way the liquid temp can be lower than...

    The only way the liquid temp can be lower than ambient is a wet coil or some kind of restriction in the condensing unit. I'm thinking it would be pretty dry after running 20 minutes. A discharge...
  3. Thread: r22 pressures

    by pvc1984
    Replies
    6
    Views
    770

    Why did the compressor go bad in the old unit? ...

    Why did the compressor go bad in the old unit?

    We need way more information to diagnose a restriction. Pressures, temperatures, SH and SC. What kind of metering device are you working with? Did...
  4. Replies
    5
    Views
    820

    I'm assuming the start components were replaced...

    I'm assuming the start components were replaced with the new compressor? Low temp compressors aren't designed to handle the higher load of medium temp compressors. You'll probably need a zp power...
  5. Replies
    9
    Views
    776

    Check the crank case heater.

    Check the crank case heater.
  6. Replies
    25
    Views
    2,845

    Meh....it'll buff out!!

    Meh....it'll buff out!!
  7. Replies
    9
    Views
    1,425

    It could be loose bulb connection or poor bulb...

    It could be loose bulb connection or poor bulb placement. Make sure the bulb is well insulated.

    Is the txv adjustable?
  8. Replies
    8
    Views
    810

    A loose txv bulb will not cause high superheat....

    A loose txv bulb will not cause high superheat. It will cause the txv to open up more and lower the superheat.

    How old is the system? Are the condensor and evap coil matched? What type of...
  9. Replies
    10
    Views
    751

    What refrigerant? What kind of metering device?...

    What refrigerant? What kind of metering device? Pressure and temperature readings? Condenser fan spinning in right direction? Noncondensibles in the system?

    It could be anything. Way too vague. We...
  10. Replies
    17
    Views
    1,570

    Do you actually mean pumping the system down or...

    Do you actually mean pumping the system down or evacuating the system? There is a huge difference. Was the milky oil in your vacuum pump? Keep changing the oil until its clear while your evacuating....
  11. Thread: Cap tube help

    by pvc1984
    Replies
    19
    Views
    1,678

    In my experience, don't go by what the chart says...

    In my experience, don't go by what the chart says on the box about sizing captubes. Call the manufacturer with model and serial and get the inner diameter and the length. If you can't match the inner...
  12. Replies
    17
    Views
    1,570

    Double post

    Double post
  13. Replies
    17
    Views
    1,570

    Definitely need way more info! What are the...

    Definitely need way more info! What are the circumstances?

    "A lot of moisture in the system" is pretty relative. A 30 ton chiller with a cracked barrel will introduce "a lot of moisture in the...
  14. Replies
    16
    Views
    2,652

    The kit that I have from united is NRP part#...

    The kit that I have from united is NRP part# NKA125M12P

    http://www.nrproducts.com/products/PDF/04-FlameTools.pdf

    I highly recommend checking them out. I'm very pleased with the set I have.
  15. Replies
    16
    Views
    2,652

    I use the NRP set I got from united. Its perfect...

    I use the NRP set I got from united. Its perfect for me. It came with everything but the tanks. It came with a #1 and #3 tips and I added a #15 rose bud tip. It covers just about everything I run...
  16. Replies
    10
    Views
    969

    Try changing the batteries too. My fieldpiece is...

    Try changing the batteries too. My fieldpiece is my backup meter and when the batteries start going dead I get all sorts of weird readings.
  17. Replies
    5
    Views
    1,612

    Get Appion...they are the best...you won't regret...

    Get Appion...they are the best...you won't regret it!!
  18. Replies
    14
    Views
    2,240

    I can't say that I've ever run into the problem...

    I can't say that I've ever run into the problem you're experiencing. I've installed the motor mate and the turbo 200 brands with great results.

    You might want to take a closer look at the...
  19. Replies
    11
    Views
    3,074

    You can't check subcooling with a receiver. Just...

    You can't check subcooling with a receiver. Just clear the glass and see how it runs before you make any adjustments to the water valve on the condenser.

    59 psi is a high suction for a 65 degree...
  20. Replies
    18
    Views
    2,121

    Don't get me wrong...I agree with you 100%. I...

    Don't get me wrong...I agree with you 100%. I would take care of the customer anyway I could and definitely do what I can.

    This thread also reminds me...on new Carriers....make sure and look at...
  21. Replies
    44
    Views
    4,495

    Nevermind that question...Forgot you need 24...

    Nevermind that question...Forgot you need 24 volts to G on a carrier for the compressor to start.
  22. Replies
    44
    Views
    4,495

    Are you losing voltage at G when the blower cuts...

    Are you losing voltage at G when the blower cuts out?

    The only advice I could give without being there is just look at the wiring diagram and trace back what's providing 24 volts to the coil.
  23. Replies
    18
    Views
    2,121

    I agree too it's probably fine. But I really...

    I agree too it's probably fine. But I really doubt carrier is gonna warranty a compressor that was wired improperly to begin with.
  24. Replies
    18
    Views
    2,121

    I would've checked pressures, temperatures, ohmed...

    I would've checked pressures, temperatures, ohmed out the compressor, and recorded amp draws on my paperwork. Record everything to CYA!! If all that checked out and the compressor sounded okay, just...
  25. Thread: evap fan

    by pvc1984
    Replies
    12
    Views
    863

    I agree with above. The good fan is drawing air...

    I agree with above. The good fan is drawing air through the dead fan and causing it to spin backwards.

    Just verify you're getting voltage to the fan spinning backwards. Sounds like you'll be...
Results 1 to 25 of 61