  1. Replies
    44
    Views
    2,453

    Do you really think the compressor would live...

    Do you really think the compressor would live long enough pumping water to accumulate that much water in the coil. For it to get in the condenser coil it would have to go through the compressor....
  2. Replies
    44
    Views
    2,453

    Just a weak spot. Finally gave out. If nothing...

    Just a weak spot. Finally gave out. If nothing else was found I would not over think the problem.
  3. Best zoning system Ive ever installed or worked...

    Best zoning system Ive ever installed or worked on is the carrier Infinity. Using all Infinity equipment and carrier dampers as well. The system lets you set air flow limits for each zones and runs...
  4. Replies
    9
    Views
    540

    Not that I endorse it but there is Aluminum line...

    Not that I endorse it but there is Aluminum line sets available. There is also a soldier that will join it to itself as well as join it to copper or brass. I know this because my company used this...
  5. "Hot Water High Limit (Domestic Hot Water Option)...

    "Hot Water High Limit (Domestic Hot Water Option)
    This mode occurs when the hot water input temperature
    is at or above 130°F for 30 continuous seconds. The DHW limit status LED on the unit...
  6. Replies
    13
    Views
    595

    Expert recommendation...... Leave it to the...

    Expert recommendation...... Leave it to the experts. Thats how they make a living.

    If it were my house I would have it replaced because thats what the expert recommended.
  7. Replies
    21
    Views
    772

    UEI DTH31. Been using the same one for years....

    UEI DTH31. Been using the same one for years. Only thing I have ever done is replace the battery once a year.
  8. Replies
    21
    Views
    2,185

    Work looks amazing (with the exception of the...

    Work looks amazing (with the exception of the source piping) but Kevin is correct. You are not supposed to hook a hot water generator to a gas water heater.
  9. Replies
    13
    Views
    622

    Try taking the UI to the outdoor unit. hook it to...

    Try taking the UI to the outdoor unit. hook it to the unit with a short piece of stat wire. Leave the wire running to the indoor hooked up inside and outside but remove the stat wire that went from...
  10. Replies
    13
    Views
    527

    are you zeroing the meter to atmospheric pressure...

    are you zeroing the meter to atmospheric pressure before you stick it in the duct?
  11. Replies
    13
    Views
    622

    Check the stat wire you have running to and from...

    Check the stat wire you have running to and from all the Infinity connections. The green and yellow are used for communication and if you have any splices that are not 100% or have been exposed to...
  12. Replies
    8
    Views
    248

    H-10 is the gold standard of the industry. It has...

    H-10 is the gold standard of the industry. It has never let me down. If it says there is a leak. Then there is a leak. I too like to visually verify but I have learned to never doubt my trusty friend.
  13. Replies
    57
    Views
    2,901

    Im not familiar with that particular leak...

    Im not familiar with that particular leak detector. On the H-10 the low, med, and high reference the leak rate not the sensitivity. So the Low setting would be most sensitive setting.
  14. Replies
    57
    Views
    2,901

    Yes put a few oz of r22 gas in the system. Then...

    Yes put a few oz of r22 gas in the system. Then fill to a good pressure with nitrogen. If you have a H-10 try searching on Medium first and if that does not come up with anything switch it to low.
    ...
  15. Replies
    24
    Views
    955

    This by no means is meant to be a training tool....

    This by no means is meant to be a training tool. I only posted it in this "Tech to Tech" forum because a few people had asked about how the material was joined. The guy doing the soldiering was a rep...
  16. Replies
    24
    Views
    955

    Let me explain how things are done here. We...

    Let me explain how things are done here.

    We have crews that do nothing but run line sets, PVC flues, and set equipment. The service department does the actual start up of the system. The systems...
  17. Replies
    24
    Views
    955

    Well I didn't find the plug inside the line set...

    Well I didn't find the plug inside the line set but all I can figure is something must have been loose floating around inside it. I cut the lines into 2 foot sections after I pulled it out and still...
  18. Replies
    24
    Views
    955

    Its on a Carrier 2 ton condenser. The line set is...

    Its on a Carrier 2 ton condenser. The line set is 3/4 suction and 3/8 liquid. I went back in with the same size. Even took the exact same rout through the house. Only took 32 holes in the drywall....
  19. Replies
    24
    Views
    955

    I checked ever inch of the line set. No kinks at...

    I checked ever inch of the line set. No kinks at all.
  20. Replies
    24
    Views
    955

    Not sure where the stuff is purchased from. We...

    Not sure where the stuff is purchased from. We use a solider that can join aluminum to aluminum, copper, or brass. Below is a link to a demonstration video.

    http://youtu.be/AiZKl0nvglk
  21. Replies
    24
    Views
    955

    378051

    378051
  22. Replies
    24
    Views
    955

    Yes Aluminum. My company gave it try. It was in...

    Yes Aluminum. My company gave it try. It was in an effort to cut cost. They have since changed their minds and we no longer use it.
  23. Replies
    24
    Views
    955

    Restriction from hell

    I love a good challenge and the chance to learn something new. But this one was ridiculous.

    With the correct charge weighed in the suction would pull into a vacuum after about 30 seconds and the...
  24. Replies
    57
    Views
    2,901

    I use 2 of the methods mentioned above and have...

    I use 2 of the methods mentioned above and have had great success with them both. The dye works great on the formicary corrosion leaks at the indoor coils. During the summer you can usually see the...
  25. Replies
    1
    Views
    196

    Liquid line solenoid valves

    Can I get some opinions on liquid line solenoid valves? Installation location, purpose, wiring, and some experiences both good and bad.

    I know they are recommended on long line set applications....