Search:

Type: Posts; User: climate01

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Are they having problems with anything else in...

    Are they having problems with anything else in the house after power issue? One solution is to have them install surge in panel for entire house.
  2. Replies
    41
    Views
    1,539

    Didn't charge him as much as I could have. Family...

    Didn't charge him as much as I could have. Family member. But I learned a few things. Mostly about welding aluminum. Really just covered most of my time and materials. I know you probably want a...
  3. Replies
    41
    Views
    1,539

    Well I should have timed it. Estimating I would...

    Well I should have timed it. Estimating I would say maybe about 3-4 hours to break down and expose leak. About 2 hrs of drive time. Dropping off coil and picking it up included. Pressure check and...
  4. Replies
    41
    Views
    1,539

    It was a XB1000. The job was more time intensive....

    It was a XB1000. The job was more time intensive. Labor not bad. Cut out . Put back. Tools do most of the work.:grin2: I charged him a flat rate to repair it. It was cheaper to repair than replace.
  5. Replies
    41
    Views
    1,539

    I also make no mention of the leak sealant. In...

    I also make no mention of the leak sealant. In this day and time you don't have to. They do research themselves. I will repair the leak if possible if not then...
  6. Replies
    41
    Views
    1,539

    My suggestion was to replace it. I explained why....

    My suggestion was to replace it. I explained why. I also am aware that if it can be fixed then you now have options. Customer wanted this option. It also had leaking valve stems, needed oil in odf...
  7. Replies
    41
    Views
    1,539

    Yesterday I repaired a 24 year old Train with a...

    Yesterday I repaired a 24 year old Train with a leak in the first row of aluminum tubing at the bottom of the condenser. Cut condenser out, removed coil to flip it over. Removed fins and cut out...
  8. Replies
    4
    Views
    488

    Furdown questions...

    I would post a picture but having issues with that process. I don't have a lot of experience with furdowns. I wanted to know most efficient ways to clean coil and drain pan on a furdown air handler....
  9. Replies
    12
    Views
    691

    Agree with burnermann. I would wire a relay for...

    Agree with burnermann. I would wire a relay for cooling until board arrives. Relay=happy customer. No relay= unhappy customer.
  10. Any follow up? I know its an old thread. If you...

    Any follow up? I know its an old thread. If you think restriction, take liquid line temps in a few places between in/outdoor coils. Find/eliminate potential problem by temperature changes.
  11. Replies
    29
    Views
    1,000

    When all else fails the process of elimination...

    When all else fails the process of elimination can be your best friend. 1. amp draw 2. cfm 3. check ll temps for changes. 4. Check mfg charging chart to reference what you should find at said...
  12. Replies
    31
    Views
    2,220

    ...

    ...
  13. Replies
    17
    Views
    976

    ...still hear the wind.:whistle:

    ...still hear the wind.:whistle:
  14. Replies
    17
    Views
    976

    Does it still work properly in cooling? Superheat...

    Does it still work properly in cooling? Superheat ? Sub cool?
  15. Replies
    7
    Views
    651

    What was supply temp?

    What was supply temp?
  16. Replies
    11
    Views
    1,724

    P-trap? Vent?

    P-trap? Vent?
  17. Replies
    11
    Views
    1,724

    Wonder what the connection on the drain pan (if...

    Wonder what the connection on the drain pan (if there is one) looks like...
  18. I will post some soon.

    I will post some soon.
  19. Rheem package unit evaporator piped to Trane split condenser

    Would like others opinion on a system where someone piped split Trane 2tta0060a3000aa/4113kp23f to one of the evaporator circuits in a Rheem rtu rrgf131076ckr. 7 lbs 7oz r22 is capacity of Trane...
  20. Take ll temp along path. Visually see how much of...

    Take ll temp along path. Visually see how much of coil is boiling off gas. Those two things tell you a lot. Good luck.
  21. Thanks rundawg.

    Thanks rundawg.
  22. Replies
    18
    Views
    1,329

    How much sub cooling? Indoor temp? How long is...

    How much sub cooling? Indoor temp? How long is unit operating between adjustments? Amp draw on compressor? Did you have 20 delta t when you installed it originally?
  23. carrier service literature/blower problem

    Anyone have service/schematics/troubleshooting literature for carrier product# FX4DNF025T00AAAA serial# 4410a68821. Has Honeywell interface module. Fan wouldn't run from vision pro or jumped at...
  24. Replies
    27
    Views
    1,561

    Trickle nitrogen while you braze. Protect...

    Trickle nitrogen while you braze. Protect o-rings, txv. Purge air out of hose before charging.


    Motivation moves the nation
  25. Replies
    27
    Views
    1,561

    x2

    x2
Results 1 to 25 of 53