Search:

Type: Posts; User: papastech

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    9
    Views
    1,012

    I think he was referring to Duct Socks...

    I think he was referring to Duct Socks
    http://www.ductsox.com
  2. Replies
    16
    Views
    2,310

    The drain going has about a 1/4 per foot pitch to...

    The drain going has about a 1/4 per foot pitch to it, its just hard to tell from the picture.
  3. Replies
    42
    Views
    1,909

    I have one of the carhartt jackets, its very warm...

    I have one of the carhartt jackets, its very warm but very stiff. I have had good luck with jackets from duluthtrading.com.
  4. Replies
    16
    Views
    2,310

    Thanks for the comments, the manufactures...

    Thanks for the comments, the manufactures instructions recommend installing a Ptrap on the condensate line.
    I was also short on fitting to install clean outs on the condensate, I have one more trip...
  5. Replies
    16
    Views
    2,310

    Forget to get pictures of the condensing unit, I...

    Forget to get pictures of the condensing unit, I will try and get them next week when I go back.
  6. Replies
    16
    Views
    2,310

    Time to update

    Installed a new Luxaire 96% efficient 2 stage variable speed furnace, with a new 14 SEER condensing unit. Also installed a new humidifier, UV light and air cleaner. Let me know what you guys think.
  7. Thread: Hack Job

    by papastech
    Replies
    2
    Views
    1,566

    Yep thats what your looking at, they removed the...

    Yep thats what your looking at, they removed the fusable plug to install a pressure switch.
  8. Replies
    4
    Views
    1,473

    DLZ Dan, I think they removed that from the...

    DLZ Dan, I think they removed that from the Satellite dish. Guess they thought it was better that then just hanging there.

    Southern Mech-Its almost funny at how much of this kind of work we see...
  9. Replies
    6
    Views
    1,149

    I would have perferred seeing a traditional...

    I would have perferred seeing a traditional remote, because you know have to dismantle all or some of the sheetmetal to get into the rear of the machine for service work.
  10. Replies
    3
    Views
    1,037

    The funny thing is, that is all the owners did....

    The funny thing is, that is all the owners did. Put on a fresh coat of paint and called it good.
  11. Replies
    3
    Views
    1,037

    Fire in the Hole

    This is a good example of what happens when you duct cleaning guys dont clean your grease ducts very well and they bypass the safety link because it to close to the fryer exhaust outlet
  12. Replies
    11
    Views
    1,683

    Nope a resturant in lovely Detroit.

    Nope a resturant in lovely Detroit.
  13. Thread: Relocation

    by papastech
    Replies
    2
    Views
    778

    True, but a little common sense goes a long way,...

    True, but a little common sense goes a long way, Or some training might go a little futher.
  14. Replies
    6
    Views
    1,149

    Sorry what you cant see is the booster fan...

    Sorry what you cant see is the booster fan drawning the air to the outside of the building, through the larger round pipe on the left.
  15. Replies
    11
    Views
    1,683

    Nope just plan old 2 x 4s, and im pretty sure if...

    Nope just plan old 2 x 4s, and im pretty sure if you removed them the unit would fall over.
  16. Replies
    4
    Views
    1,473

    Who needs sealtite.

    Another lost job, but why does the electrical need to be in sealtite and a weather proof box anyways.
  17. Thread: Relocation

    by papastech
    Replies
    2
    Views
    778

    Relocation

    Was working on a walk-in cooler for a new customer, box temp would get below, 45 degrees, after looking over the unit, and trying to adjust the superheat on the tx-valve was getting some really...
  18. Replies
    6
    Views
    1,149

    It comes from space

    The owners of this resturant water cooled ice machine died, so they bought a new used air cooled machine. But when the temps in the kitchen get to a 100+ degrees that couldnt figure out why the...
  19. Replies
    11
    Views
    1,683

    The things you see

    I was going through some old photos and came across these, I just dont know what some people are thinking. What you are looking at is 2 x 4 holding up a rooftop unit, because the curb adapter they...
  20. Replies
    0
    Views
    831

    Garland ECO convection oven

    I have a customer that says there convecton oven keeps reading an ERROR #5, I cant find anything in there online stuff that says what a #5 error is. Any help would be great.
  21. Replies
    4
    Views
    742

    Case Parts also has stuff for Barr doors...

    Case Parts also has stuff for Barr doors
    http://www.caseparts.com/catalog/?i=
  22. Replies
    13
    Views
    2,370

    Yeah it took the electricans awhile to do there...

    Yeah it took the electricans awhile to do there thing, looks better with out there stuff in the way.
  23. Replies
    10
    Views
    1,789

    I ran across a nice one yesterday, customer...

    I ran across a nice one yesterday, customer needed a chimney liner installed per the city. Was looking at the furnace 1000 sqare foot house with a 100,000 btu furnace, the return air was 6 x 20 cut...
  24. Replies
    4
    Views
    1,729

    This is a Make up air unit for a resturant. This...

    This is a Make up air unit for a resturant. This is a little diffenrent set up then I have seen in the past. The dump the supply air from the MUA into the retrun plenums of the rooftop units and then...
  25. Replies
    13
    Views
    2,370

    A lot of places we do, the roofers dont like the...

    A lot of places we do, the roofers dont like the equipment rail secured to the roof. So we put extra material under the rails and let it be.
  26. Replies
    10
    Views
    1,789

    No that the duct box from the orginal unit, on I...

    No that the duct box from the orginal unit, on I believe these were old bryant or carrier unit. The left side of the unit is side on the old curb still as well
  27. Thread: Economizer

    by papastech
    Replies
    4
    Views
    1,486

    Economizer

    Can you see whats wrong with this picture
    http://i489.photobucket.com/albums/rr256/woejitt/IMAGE_00090.jpg

    http://i489.photobucket.com/albums/rr256/woejitt/IMAGE_00091.jpg

    And if I remember...
  28. Replies
    4
    Views
    1,729

    The sterling unit in the picture is from another...

    The sterling unit in the picture is from another building, but the same style as the one we replaced
  29. Replies
    4
    Views
    1,729

    New make up air

    http://i489.photobucket.com/albums/rr256/woejitt/IMAGE_00007.jpg
    Out with the old

    http://i489.photobucket.com/albums/rr256/woejitt/002.jpg
    ...
  30. Replies
    13
    Views
    2,370

    New refrigeration units for a school

    http://i489.photobucket.com/albums/rr256/woejitt/IMAGE_00017.jpg

    http://i489.photobucket.com/albums/rr256/woejitt/IMAGE_00020.jpg
    ...
  31. Replies
    10
    Views
    1,789

    How not to support a new rooftop

    http://i489.photobucket.com/albums/rr256/woejitt/IMAGE_00082.jpg

    http://i489.photobucket.com/albums/rr256/woejitt/IMAGE_00080.jpg

    Was going through my old photos and came across this, it is on...
  32. Thread: test

    by papastech
    Replies
    0
    Views
    285

    test

    http://i489.photobucket.com/albums/rr256/woejitt/IMAGE_00082.jpg
  33. Replies
    6
    Views
    1,744

    Had a customer with a set up like that, Newer...

    Had a customer with a set up like that, Newer Coleman straight cooling unit with an 80s vintage air handler. Customer didnt understand why it iced up all the time. Finally sold them a Stulz unit
  34. Thread: My Veto

    by papastech
    Replies
    47
    Views
    4,719

    I had my first veto bag for 3 years before I went...

    I had my first veto bag for 3 years before I went up to the XL, going a year strong with that bag, Gave my old bag to one of my techs and he still uses it everyday. No complaints from here.
  35. Replies
    14
    Views
    2,578

    I've had mine about two weeks now, and use them...

    I've had mine about two weeks now, and use them everyday. No problems so far. Really small screws are tough to grab, but can pick up screws from panels ok. I also have the tundra from ironclad for...
  36. Replies
    14
    Views
    2,578

    Just got in my iron clad cold conditon gloves and...

    Just got in my iron clad cold conditon gloves and they work very well. used them with the snow blower the other day, my hands stayed warm and dry.
    ...
  37. Replies
    3
    Views
    1,721

    Lang Convection oven

    Im looking for service and or trouble shooting manual for this oven, Model # ECCO-PT S/# W49969. Thanks for any help
  38. Thread: no cooling

    by papastech
    Replies
    28
    Views
    8,182

    Payson This is a bar in a not so nice...

    Payson

    This is a bar in a not so nice neighborhood. You know, one of those that no one see anything
  39. Thread: Retrofit

    by papastech
    Replies
    6
    Views
    1,867

    The installation instructions say to use tapered...

    The installation instructions say to use tapered reducers on the intake and exhaust pipe.
  40. Thread: no cooling

    by papastech
    Replies
    28
    Views
    8,182

    The small unit looks like it was an ICP product...

    The small unit looks like it was an ICP product of some sort, 5-ton Larger unit in the back was a lennox.
    Owner said the equipment was at least 10 years old. What you can see of the beer bottles is...
  41. Thread: no cooling

    by papastech
    Replies
    28
    Views
    8,182

    Went out for a no cooling call the other day and...

    Went out for a no cooling call the other day and when we got on the roof this is what we found

    http://img164.imageshack.us/img164/5946/workstuff0069xl.jpg
    ...
  42. Thread: Why ?

    by papastech
    Replies
    2
    Views
    1,649

    I have see alot of those through the years in a...

    I have see alot of those through the years in a pizza chain here. The keep there rack of dough under the evaporator to keep it from drying out. And yes the suck to work on
  43. Replies
    14
    Views
    2,451

    Yes the LEDS you see on the front are UV lights.

    Yes the LEDS you see on the front are UV lights.
  44. Replies
    14
    Views
    2,451

    Its a 120 with 5-tons of cooling. Which requires...

    Its a 120 with 5-tons of cooling. Which requires dual returns
  45. Replies
    14
    Views
    2,451

    http://img122.imageshack.us/img122/1150/quas0057ao...

    http://img122.imageshack.us/img122/1150/quas0057ao.jpg
  46. Replies
    14
    Views
    2,451

    Actually it was easier to run the full size drop...

    Actually it was easier to run the full size drop all the way to the floor, and take a return off of each side of it into the furnace
  47. Replies
    14
    Views
    2,451

    There is a return on the other side also, just...

    There is a return on the other side also, just cant tell by the picture sorry
  48. Replies
    14
    Views
    2,451

    Old furnace, what a pain to remove from the...

    Old furnace, what a pain to remove from the basement

    http://img108.imageshack.us/img108/1300/picture0040xb.jpg

    new furnace 90i with all the bells and whisles...
  49. Thread: testing

    by papastech
    Replies
    0
    Views
    326

    Before...

    Before
    http://img231.imageshack.us/img231/4707/hodell0013ec.jpg

    After
    http://img231.imageshack.us/img231/8526/mcdonalds306southgate0261hi.jpg
  50. Thread: testing

    by papastech
    Replies
    0
    Views
    278

    http://img231.imageshack.us/img231/4707/hodell0013...

    http://img231.imageshack.us/img231/4707/hodell0013ec.jpg

    [Edited by papastech on 05-14-2006 at 10:03 AM]