  1. Replies
    14
    Views
    2,580

    I find removing the rubber tee easier, but if it...

    I find removing the rubber tee easier, but if it hasn't been serviced before, you have to fight with it a little to get it off. 1/4" stubby nut driver and some patience. :.02:
  2. No apology needed!:cheers: I take my work very...

    No apology needed!:cheers:
    I take my work very seriously. I may be anal here, or sound like I have OCD, but I would still like to know the code, section, etc.
    I just read through section 6 of the...
  3. Thanks Gasguy. I know that applies to gas...

    Thanks Gasguy. I know that applies to gas pressure relief devices, (3' or 1m in the electrical code) but does that also apply to BBQ quick disconnects?
  4. I have been licensed for over 15 years. I own,...

    I have been licensed for over 15 years. I own, have read thoroughly, and have a better understanding than most (of the codes) of the latest edition B-149.1-10 including the most recent updates. Maybe...
  5. Not too difficult, if you are a pro. Get your...

    Not too difficult, if you are a pro. Get your technical post count up and apply. You may need some proof of credentials.
  6. Apparently his friend, (who was an electrician in...

    Apparently his friend, (who was an electrician in Europe) told him that it is dangerous. I told him he may get a shock if he tries to plug the BBQ into the electrical outlet! LOL.
  7. ng

    ng
  8. Gas bbq outlet to electrical outlet clearance code?

    I recently attended a call where the HO just moved in and is concerned about a BBQ quick disconnect outlet (equipped with a gas shut-off) is about a foot away from an electrical outlet. The home is...
  9. Replies
    17
    Views
    1,227

    Ok, I'm done whining! Now we can get back to...

    Ok, I'm done whining! Now we can get back to learning. LOL
  10. Replies
    17
    Views
    1,227

    I understand that in order for me to keep my job,...

    I understand that in order for me to keep my job, the company needs to be making money. That is not the issue here. My work is being completed in the allotted time, but I think the boss may be...
  11. Replies
    17
    Views
    1,227

    I started working for my current employer about 6...

    I started working for my current employer about 6 months ago. Most times when I go to a PM (regular customers) I hear, "you take a lot more time than the other guys" and have to explain why. Without...
  12. Replies
    37
    Views
    2,411

    Poll: Started working for a Lennox dealer about 6...

    Started working for a Lennox dealer about 6 months ago. Before that I didn't have much interaction with the product, and found them a little intimidating. Now......different (maybe).......difficult...
  13. Replies
    8
    Views
    1,891

    With all due respect. It sounds like you don't...

    With all due respect. It sounds like you don't know what you are doing. So please call someone who does, before someone gets hurt! Or worse!
  14. Replies
    4
    Views
    502

    Thanks membership committee! I look forward to...

    Thanks membership committee! I look forward to learning and sharing!
  15. Replies
    4
    Views
    502

    I'm sorry, I guess you are rite. Forgive me for...

    I'm sorry, I guess you are rite. Forgive me for being exited about using this site. I was not trying to be pushy. "Just like a kid before Christmas" LOL
  16. Replies
    4
    Views
    502

    Waiting Patiently

    Hey guys, my name is Louis from Ontario, Canada eh! I have been in this trade since 1998, mostly as an installer. I have been doing service work for about 2 years now, and have learned quite a bit....
  17. Definitely not easier to remove burner box on G61!

    Definitely not easier to remove burner box on G61!
  18. Thread: Payne Furnace

    by CELSIUS
    Replies
    18
    Views
    1,392

    Are we talking no start or fail to start after...

    Are we talking no start or fail to start after pre purge?
  19. Replies
    19
    Views
    1,572

    If the inspector came to that conclusion based on...

    If the inspector came to that conclusion based on a visual inspection alone.Without any testing? Then retarded he is!
  20. When I was trained on the G61, they told me to...

    When I was trained on the G61, they told me to remove the burner box cover and rubber exhaust boot to access the sensor, so I never really looked for an easier option. furnacedoc are you saying it's...
  21. Replies
    19
    Views
    1,572

    Did you check your gas pressures, and clock the...

    Did you check your gas pressures, and clock the meter? Maybe you are over-firing?
  22. Replies
    33
    Views
    5,063

    I guess I can wait till March for the CMX show in...

    I guess I can wait till March for the CMX show in Toronto. Lots of good stuff there.
  23. Replies
    33
    Views
    5,063

    Thanks for all the great replies guys! I know...

    Thanks for all the great replies guys! I know about the great products you suggested and I'm sure I can purchase them online, but when I pay that much money for something I like to try it out before...
  24. Replies
    33
    Views
    5,063

    Need a good multimeter

    Could anyone tell me where I can find a good multimeter for hvac in the southern Ontario area. I'm tired of carrying around 4 multimeters! Need one for clamp-on amp + volts + ohms/continuity + ufd +...
  25. WOW! I was going to buy a new deburring tool, but...

    WOW! I was going to buy a new deburring tool, but that looks like a much better investment.