  1. The furnace is 17.5 wide & the coil is 21 wide. ...

    The furnace is 17.5 wide & the coil is 21 wide. So 3.5 inchs to one side not centered!
  2. Replies
    7
    Views
    900

    So is it a self contained inside heat pump with...

    So is it a self contained inside heat pump with no outdoor unit? Also I am assuming if need to replace would choose too put down flow air handler in & place outdoor heat pump?
  3. Replies
    7
    Views
    900

    Insider Mobile home unit???

    I am looking at a 97 Model trailer with a Insider system. Is this a self contained inside unit? I can't find a a/c condenser outside and the guy sailing it said that the compressor was inside? Can...
  4. Replies
    15
    Views
    1,048

    [QUOTE=tipsrfine;12299331]Are the supplies run...

    [QUOTE=tipsrfine;12299331]Are the supplies run through the attic? Where is the t-stat located in relation to the bedrooms?


    The t-stat is in the living room away from all the bedrooms. We have...
  5. Replies
    15
    Views
    1,048

    I just looked at the ahri info. For this system. ...

    I just looked at the ahri info. For this system. Cooling cap. 32,200 with cfm being at 1050 and heating cap. 29,600 at 47 degress. I noted that at 17 degress heat cap. 17,700. It ahri number is...
  6. Replies
    15
    Views
    1,048

    Thanks guys all your ideas make sense. With...

    Thanks guys all your ideas make sense. With regard to the return air, I have one 20x25 With a 14 or 16 inch flex duct going to my air handler in the attic. It is located in center of my home. The...
  7. Replies
    15
    Views
    1,048

    it is Monroe, LA. Louisiana

    it is Monroe, LA. Louisiana
  8. Replies
    15
    Views
    1,048

    Yes that was a typo. What I meant was system...

    Yes that was a typo. What I meant was system worked fine this pass summer. This is my 1st time with heat pump in the home. Refrigerant was checked along with wiring of the system and everything...
  9. Replies
    15
    Views
    1,048

    Bedrooms not heating but cooling fine???

    Hello gentleman,

    I have a strange problem with my new Trane hvac system. My system cools my house fine during the summer but does not heat my bedrooms up during the summer. This is puzzling to...
  10. Replies
    9
    Views
    1,571

    Hey thanks for the info. So 41,900 btu then it...

    Hey thanks for the info. So 41,900 btu then it is a 3.5 ton unit. The load was ran again today this time included a garage area that needs to be heated and cooled the load came out to be 40,237...
  11. Replies
    9
    Views
    1,571

    Ok that makes since. I am looking at replacing...

    Ok that makes since. I am looking at replacing this unit with a 3 ton 36,800 btu unit matched heat pump system. The load came out to be 37,650 which is dead on the 38,000 btu compressor. What I...
  12. Replies
    9
    Views
    1,571

    That is just it the model number is gone off the...

    That is just it the model number is gone off the unit. That is why I was going by compressor model number. I would believe that it would it would be 3 ton or 3.5 judging by the btu of 38000btu. ...
  13. Replies
    9
    Views
    1,571

    So you are saying that it is a 3 ton compressor...

    So you are saying that it is a 3 ton compressor then? Because 3.5 ton would be larger. The compressor said Copeland scroll on top of it.
  14. Replies
    9
    Views
    1,571

    Copeland Compressor size

    I am trying to figure out what size copeland scroll compressor i have is?

    Model # YHB2-0301-PFV it was in a 30 plus year old Rudd Heat Pump.


    Thanks
    ARW
  15. Replies
    12
    Views
    847

    The installing company came back out and checked...

    The installing company came back out and checked the furnace as I thought it was set to the lowest speed for heat. An to to be honest I have not been paying that much attention to the system as I...
  16. Replies
    5
    Views
    435

    Warranty Question???

    Does every Contactor who installs Com. or Residental Systems have to offer 1 year labor warranty per law. I live in Louisiana and was told that this is not the case. I disagree, as i thought by law...
  17. Replies
    2
    Views
    1,096

    What size Lennox packAge unit?

    I am trying to figure out what size this Lennox package is for cooling btu i can see that it is 75000 btu for heating but don't no what the cooling size it is? Her is the Model #

    GCS16-413-75-6T
  18. Replies
    12
    Views
    847

    Agreed but still wondering if anything else can...

    Agreed but still wondering if anything else can be done since lowest setting for heating has been set at the furnace? Again will the XL 20i a/c unit matched with XC 80 auto adjust itself since it is...
  19. Replies
    12
    Views
    847

    The furnace is XC 80, 80,000 btu due to best...

    The furnace is XC 80, 80,000 btu due to best perforce ratings. It is arhi rated. I don't have the model number in front of me. My understanding is that t-stat will adjust blower speed with furnace...
  20. Replies
    12
    Views
    847

    Correct me if I am wrong but on comm. unit it...

    Correct me if I am wrong but on comm. unit it sets itself? The XC furnace only has a couple of settings. Cooling & heating cfm, 24 volt or comm. unit. When you put in comm. mode t-stat matchs a/c...
  21. Replies
    12
    Views
    847

    Update: the furnace cfm settings for 2 ton unit...

    Update: the furnace cfm settings for 2 ton unit were set to 1200 which is the lowest this furnace will allow for heating. So same thing with the blower speed as I talked about in earley posts. ...
  22. Replies
    12
    Views
    847

    It is a straight a/c XL20i with a XC 80 gas...

    It is a straight a/c XL20i with a XC 80 gas furnace. When it was turned onto heat the yesterday morning ran at low speed for about 1 min maybe 2 then kicked up to higher speed. Know I no in heat...
  23. Replies
    12
    Views
    847

    Trane comm. System settings?

    Guys I am curious if XC 80 Furnace with XL20i system with 900 t-stat controls fan speed on heating & cooling modes! Also what about staging of the furnace ? Does the comm. 900 stat control that? ...
  24. Poll: This is fact, I look over entire duct work system...

    This is fact, I look over entire duct work system when in the field and see how much cfm/btu system will carry! So customers saying that there system has done good in past but now need new system. ...
  25. Replies
    39
    Views
    2,534

    I have always used Remrate to size homes out over...

    I have always used Remrate to size homes out over the years. I have tried all load programs and all are pretty much the same. With that said Manual J and wright soft are up there with Remrate to...