    The rotted flue was caused by a humidifier.I...

    The rotted flue was caused by a humidifier.I replaced the flue assembly with OEM equipment.What was happening was when the blower would come on,it would draw water in too fast from the...
  2. Replies
    21
    Views
    6,159

    I have to agree with the engineer being an...

    I have to agree with the engineer being an idiot.The carried low boy oil furnaces all have the combustion vent running through the blower return area.I had a customer who's vent rotted through on a...
  3. Replies
    21
    Views
    6,159

    Just a couple stupid questions.Why is there a...

    Just a couple stupid questions.Why is there a trap on the secondary drain that looks like its just draining into the pan?And why isn't there a trap on the drain line?Why didn't you put a spacer...
  4. Replies
    2
    Views
    2,066

    We recently install a 15 seer a/c system.The HO...

    We recently install a 15 seer a/c system.The HO will get a rebate from the utility company for doing so.He will recieve additional rebates if we perform "Digital Commissioning".Does anyone know what...
  5. Replies
    9
    Views
    2,839

    Now I'm confused.How can you suck air in with a...

    Now I'm confused.How can you suck air in with a louvered vent termination?Won't the louvers get sucked closed?
  6. Replies
    12
    Views
    1,561

    Payson,I have the same camera phone.How do you...

    Payson,I have the same camera phone.How do you download pics to here from your phone?
  7. Replies
    9
    Views
    2,839

    Where is the exhaust for the unit in the second...

    Where is the exhaust for the unit in the second pic?I thought the intake and exhaust had to be within so many feet or inches from each other so as not to cause problems with pressure switches.
  8. Replies
    21
    Views
    4,383

    Looks to me like someone mounted the t-stat where...

    Looks to me like someone mounted the t-stat where the doorchime should be.
  9. Thread: scary

    by eagle1154
    Replies
    13
    Views
    3,184

    Is that furnace competing for combustion air with...

    Is that furnace competing for combustion air with return air?I don't think that is even legal.How does it even work?
  10. Replies
    17
    Views
    1,544

    You might also check to see how much water...

    You might also check to see how much water pressure you have in the boiler.You'll need a minimum of 18 pounds to get the water up to the second floor.There is a formula to use on how much water...
  11. You have to count the flashes as they...

    You have to count the flashes as they happen,usually a series of short flashes followed by a series of longer flashes,kinda like morse code.Then somewhere on the unit there will be a paper that tells...
  12. Replies
    13
    Views
    1,254

    I would call another service company,one that...

    I would call another service company,one that deals with lennox.I'm sure it can be replaced with something else.
  13. Replies
    13
    Views
    1,254

    Almost all controls can be replaced.Most are just...

    Almost all controls can be replaced.Most are just 24 volt valves.If he contacts a reputable supply house,I'm sure they can cross reference something.
  14. Replies
    13
    Views
    1,254

    Can't you just get a new control?

    Can't you just get a new control?
  15. Replies
    19
    Views
    1,487

    This was a new install,indoor and...

    This was a new install,indoor and outdoor.According to the lennox tech support guy,a 13 seer unit holds more refrigerant than a 10 seer indoor coil can handle.I will keep you posted when we change...
  16. Replies
    19
    Views
    1,487

    Thanks to all who replied.Turns out the Lennox...

    Thanks to all who replied.Turns out the Lennox salesman gave us some bad info.The unit was a mismatch.He sold us a 13 SEER condenser,but the Air Handler was only 10 Seer.Hence the indoor coil...
  17. Replies
    19
    Views
    1,487

    I installed a bi-directional filter drier.Have...

    I installed a bi-directional filter drier.Have you seen any bad ones?
  18. Replies
    19
    Views
    1,487

    I thought system was overcharged also,removed...

    I thought system was overcharged also,removed some refrigerant,didn't do any good.System has TXV inside and outside.Subcool temp was 12 degrees in cooling mode,suction line temp was all the way up to...
  19. Replies
    19
    Views
    1,487

    I understand that it shouldn't.But the pressures...

    I understand that it shouldn't.But the pressures shouldn't be that high anyway.I was doing a start up so people could get a CO.
  20. Replies
    19
    Views
    1,487

    Could use a little help with a HP problem.A new...

    Could use a little help with a HP problem.A new install installed by our company.It's a Lennox HP26 unit.Works perfect in cooling mode,but when switched to heating mode,High side pressure goes all...
  21. If you ever install a carrier condensing unit,you...

    If you ever install a carrier condensing unit,you must install the metering device that comes with the condensing unit.And why wouldn't you check to be sure if the evap had a metering device in it...
  22. I was always taught that the guy who installs the...

    I was always taught that the guy who installs the condensing unit should install the metering device that comes with the condensing unit.I wouldn't blame the installers for that one.Whoever installs...
  23. Replies
    17
    Views
    2,275

    I would assume the system is 220 volts,I'm...

    I would assume the system is 220 volts,I'm curious as to why you only have 110 at the terminals
  24. Replies
    17
    Views
    2,275

    You could try a hard start kit.

    You could try a hard start kit.
  25. Replies
    12
    Views
    3,237

    I just went to a Lennox 410A class,and the...

    I just went to a Lennox 410A class,and the instructor said they tested stay brite#8 in the 410A systems and said it is OK to use.They found it to be as strong as braze and no contaminents were found...