Search:

Type: Posts; User: stormrider

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Replies
    12
    Views
    1,359

    What do you want from a service manager?

    If wishes could come true, tell me your ideal service manager? Would you have one that relates to your needs more that the company? Would you want some one who has been a tech, or some one that has a...
  2. Replies
    2
    Views
    1,294

    Have you tried to descale the unit. If you have...

    Have you tried to descale the unit. If you have hard water it's a good think to do serveral times a year.
  3. Replies
    5
    Views
    2,741

    Try these guys

    etundra.com they have after market suppliers. Just give them a model and serial number and they, most likely be some help.
  4. Replies
    23
    Views
    2,370

    The settings

    I too have used the Ranco control. Put the sensor in the coil and set the cut in at 40 and the cut out at 15. I have coolers with product temps at 32-35 degrees and a clear coil.
  5. Replies
    2
    Views
    580

    Hard?

    How do you know that your way isn't the easy way?
  6. Replies
    8
    Views
    1,404

    um

    ...not sure if I should stand up or sit down. Either way it looks like I'll need some personal lubracation.
  7. Replies
    24
    Views
    4,121

    20 year old

    By the time you get the saft out of the blower it's going to be out of balanced.

    Replace it!!

    Grainger has alot of fans in stock.
  8. Replies
    8
    Views
    1,404

    In a hurry?

    Call on a local tin shop and have one made special.
  9. Replies
    12
    Views
    7,298

    bagomike

    OK , first
    What kind of contract do you want to offer?
    I need some questions answered;
    Do you want to offer a simple PM contract, maybe with a service agreement?
    Do you want to offer a service,...
  10. Replies
    12
    Views
    7,298

    Nope

    Service contract should be customized to each customer. You will find that there are too many differences for just one boiler plate contract.

    I would be happy to help with your questions. I have...
  11. Replies
    1
    Views
    1,218

    Guy walks into a bar and pulls a tiny grand piano...

    Guy walks into a bar and pulls a tiny grand piano out of his pocket. Then he pulls out a little guy who site down and begins to play. "Where'd ya get that?" bartender asks. "I have a magic bottle;...
  12. No worries, Bubba will take good care of him.

    No worries, Bubba will take good care of him.
  13. Replies
    17
    Views
    1,708

    Could be this

    The True 3 door freezers are equiped with a CPR. Did check its setting?
  14. Replies
    2
    Views
    708

    Northern Colorado

    Got just what you need. call 970-568-0900 ask for Rolondo. $25-$30 an hour. $$$$Bonus$$$$
  15. Replies
    12
    Views
    1,206

    You could try this

    Have you ever heard of the JTPA(Jobs in Trianing and Partnership Act 1982)? This is a program that is administered by your state's job service dept.

    What this progam does is it pays ,from %50 and...
  16. Replies
    19
    Views
    1,704

    In the first picture there is a sign that says,...

    In the first picture there is a sign that says, "crabby?". I'll bet who ever poked the hole and his boss is.
  17. the resistor is in series with the stat. When the...

    the resistor is in series with the stat. When the stat closes the board would sence the resistor and do what it needs to do.

    The particulars I can't remember so goto their web site and see.
  18. Ice O Matic did it

    Ice O Matic years ago had a wunderful ice machine with a wunderful control board.

    The evap thermister would never work for long so, Ice O Matic used a 5Kohm resistor and a "close on drop" t-stat...
  19. Replies
    10
    Views
    1,358

    not new

    I have had some other issues there as well with THAT parts dept.
  20. Replies
    14
    Views
    1,878

    I'll take a stab at it

    With out a touch more info here is my input.

    Sounds like you have an old McQuay with a sigle feed, unlike the newer evaps with multi-feeds. With the bottom of the evap icing up you could be...
  21. Replies
    8
    Views
    1,018

    Let's face it

    As long as there are customers that want their stuff fixxed in a 'less than affordable' mannor hacks will exist.
  22. Replies
    1
    Views
    489

    try this guy

    RSI 970-587-0370
  23. Replies
    11
    Views
    814

    R12

    Thanks for replying. I rise this question because a few years ago I had an R134-a walk in freezer that is remoted to the roof. The thing was running fine until the owner cut a tree down that was...
  24. Replies
    11
    Views
    814

    I have noticed some recent postings that some of...

    I have noticed some recent postings that some of you talked about remote units that have R134-a. My question to you is, With such a low saturation point of R134-a, about 130ish degrees, how can it be...
  25. Replies
    10
    Views
    746

    PDA's

    Out west our palm units consist of a palm full of business cards with a lot of writing on there back sides.
Results 1 to 25 of 64
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event