    www.tranehk.com/eng_news/vol42_2.pdf[URL="www.tran...

    www.tranehk.com/eng_news/vol42_2.pdf[URL="www.tranehk.com/eng_news/vol42_2.pdf"]
    here is a link to single zone vav. This is probably why they want to add supply fan drives. Duct static sensing is...
  2. Replies
    21
    Views
    773

    Single zone vav has become common practice in my...

    Single zone vav has become common practice in my neck of the woods. Similar to Chuz's suggestion but a few modifications. Only works properly with modulating cooling (digital scroll or chilled...
  3. Thread: King valve

    by ckartson
    Replies
    55
    Views
    1,846

    There is no hating here. I like this site also. I...

    There is no hating here. I like this site also. I do vent sometimes and it might come out wrong but it's all good.
  4. Thread: King valve

    by ckartson
    Replies
    55
    Views
    1,846

    I don't freak when a customer calls their...

    I don't freak when a customer calls their equipment or components by the wrong names, I expect it. They don't know and are not professionals in our industry. But when we call refrigerant Freon and...
  5. Thread: AC question

    by ckartson
    Replies
    23
    Views
    1,232

    Did this system work properly before the...

    Did this system work properly before the compressor change. Seems to me you inherited some one else's mis application or sizing issue. As was mentioned are exhaust fans and makeup air up to speed?
  6. Thread: King valve

    by ckartson
    Replies
    55
    Views
    1,846

    The term is used very loosely any more. King...

    The term is used very loosely any more. King valve was the valve that is mounted on the outlet of a receiver. Otherwise you had a liquid line shutoff valve or a suction line shutoff valve. Now it...
  7. Replies
    81
    Views
    3,040

    Thank you Jtrammel. Evacuation is not a form of...

    Thank you Jtrammel. Evacuation is not a form of leak checking. Pressure tests are. Evac leak checks are only good to 14.7 psi but pressure tests are good to whatever pressure is supplied. System is...
  8. Replies
    6
    Views
    530

    this is correct

    this is correct
  9. Replies
    37
    Views
    3,280

    Water Lines?

    Water Lines?
  10. Replies
    73
    Views
    4,235

    10 sh in cooling mode doesn't mean 10sh in heat...

    10 sh in cooling mode doesn't mean 10sh in heat mode. Heat mode uses a different expansion device. I'm not saying the comp couldn't have just failed due to nothing you did wrong.
  11. Replies
    20
    Views
    1,236

    Three phase motors will not have caps.

    Three phase motors will not have caps.
  12. Replies
    13
    Views
    2,279

    You look very proud of your machine! Phones...

    You look very proud of your machine! Phones actually take colored pictures.:grin2:
  13. That style diffuser may have a set of adjustable...

    That style diffuser may have a set of adjustable blades behind the ones we see. Can't tell from photo. Good point. Otherwise duct traverse and set cfm. Does the AHU fan have a VFD?
  14. All branch ducts are to have manual volume...

    All branch ducts are to have manual volume dampers. It's code in my area anyway. That's how air balance is done.
  15. Air balancer should set fan speed. Did you have...

    Air balancer should set fan speed. Did you have an air balance done? You should get a copy of report .
  16. Landlord especially should have service...

    Landlord especially should have service contracts. Filters should never be left up to tenants.
  17. Prices are not allowed but I'm sure the mods will...

    Prices are not allowed but I'm sure the mods will catch it and delete pricing. As far as workmanship send photos. What repairs were performed. If a coil box HAS to be cut open sheet metal patch and...
  18. Thread: Stupid Forum

    by ckartson
    Replies
    60
    Views
    2,380

    I don't get why you are so angry. All your...

    I don't get why you are so angry. All your questions were answered.
  19. Replies
    26
    Views
    1,151

    It's not supply air because the heat ex is after...

    It's not supply air because the heat ex is after that sensor. It is mixed air sensor because as was mentioned it does control econo but also controls second stage cooling when energized. This is a...
  20. PHM it's good to see a post from you and that...

    PHM it's good to see a post from you and that one's a doozy:grin2: I hope everything's ok.
  21. Replies
    5
    Views
    496

    Roof Top Unit, heat and air

    Roof Top Unit, heat and air
  22. Replies
    26
    Views
    1,260

    David! Are you out there, did you get amp draws,...

    David! Are you out there, did you get amp draws, was it over amping and going off on internal overload or motor protector.
  23. Replies
    21
    Views
    1,418

    I would have a pro look at it. It probably isn't...

    I would have a pro look at it. It probably isn't correct but need to see the outside termination also. Intake is supposed to be terminated above snow line but really you need to have a pro out there....
  24. Replies
    8
    Views
    1,311

    You said the actuator is connected to an AO...

    You said the actuator is connected to an AO already. Also 24 v connected to actuator through a DO. Sounds to me as if the actuator is enabled by the DO and controlled by the AO. Was it a replacement...
  25. Replies
    9
    Views
    1,485

    Bypass open.

    Bypass open.
  26. Replies
    744
    Views
    152,431

    What was wrong?

    What was wrong?
  27. Replies
    10
    Views
    1,078

    Ammoniadog, curious about what is detrimental...

    Ammoniadog, curious about what is detrimental about low amp draw? Also how low are you talking?
  28. Replies
    24
    Views
    3,266

    Outstanding job! When I worked on Trane equipment...

    Outstanding job! When I worked on Trane equipment for one company I had a resistance decade box. You exceeded that box. Only difference is the decade box could be used for other troubleshooting,...
  29. Replies
    27
    Views
    2,483

    GenesisRefrig, I also remember filling Styrofoam...

    GenesisRefrig, I also remember filling Styrofoam cups we R 12 back before reclaim when people would ask for a little freezone because there car was a little low. They would walk away with a cup of...
  30. A large hospital in the Cleveland area requires...

    A large hospital in the Cleveland area requires an open ceiling permit if we have to remove a ceiling tile. They don't argue the bill even though it may be three or four times more due to the legwork
  31. You got half a diagnosis. The other half would...

    You got half a diagnosis. The other half would have been amp draws. This would tell if all elements were energized. I would get a service contractor out if I am serious about buying.
  32. Replies
    6
    Views
    1,787

    Jogas, what #BV is keeping the fans on? Also if...

    Jogas, what #BV is keeping the fans on? Also if you think the wrong program was used look in Alerton standards for a parallel fan program. VAV box programs are usually selected from there.
  33. Replies
    62
    Views
    2,959

    I think you mean co sensors correct?

    I think you mean co sensors correct?
  34. Replies
    22
    Views
    1,423

    To put this in perspective, the service person...

    To put this in perspective, the service person found a failed combustion motor and possible unreliable control board and did the right thing in suggesting replacement. The next step which he wouldn't...
  35. Do you have outside air ducted to the furnace's...

    Do you have outside air ducted to the furnace's return air for ventilation? If so an automatic damper should be installed. Are you running some sort of exhaust when this happens? Typically warm air...
  36. Replies
    10
    Views
    875

    Please put hans back in pockets it's -7F...

    Please put hans back in pockets it's -7F here.:grin2:
  37. Replies
    10
    Views
    875

    What is the little green box for

    What is the little green box for when hovered over say,"Standing around truck with hands in pockets" or something to that effect. I don't ever remember seeing that before
  38. Replies
    6
    Views
    548

    Just one more thing to add to HVAC69's excellent...

    Just one more thing to add to HVAC69's excellent explanation, if this is controlled by a DDC controller or any controller for that matter two binary outputs are needed. One for open and one for close.
  39. Replies
    8
    Views
    788

    any change of a diagram. Are you running a...

    any change of a diagram. Are you running a primary loop from boiler to tank and back and another loop to zone?
  40. Replies
    11
    Views
    1,535

    I recently ended up replacing a speed control and...

    I recently ended up replacing a speed control and combustion motor for th same reason. Combustion fan was running to slow. Also had terrible smelling flue gasses. Obviously check heat exchanger...
  41. Fuses protect the conductors. wires are sized per...

    Fuses protect the conductors. wires are sized per amperage and fuses stop current if value is exceeded. Fuses aren't always used to protect a device. Some smaller control fuses do protect an...
  42. Replies
    6
    Views
    651

    Cheap way, Supply 55f to 65f from RTU based on...

    Cheap way, Supply 55f to 65f from RTU based on OA temp and provide electric zone reheat for each zone. Reheats are duct mounted. Can be modulating. I don't think VVT will work well with that many...
  43. Replies
    50
    Views
    3,581

    Whether the trans has a grounded secondary or not...

    Whether the trans has a grounded secondary or not you should still see 24 vac across the secondary. Or read from R to C on the terminal strip.
  44. Replies
    31
    Views
    1,965

    That makes no sense. Sequencers fail and can be...

    That makes no sense. Sequencers fail and can be replaced. Many companies work on electric heat. If the equipment has been drastically redesigned then maybe no one wants the responsibility.
  45. Replies
    17
    Views
    1,429

    I have seen similar480v 3 phase heater package on...

    I have seen similar480v 3 phase heater package on a singe phase 230 v carrier resi ahu. They sold a single point power package which contained a 480 to 240 transformer to power the furnace fan and...
  46. Replies
    10
    Views
    929

    What is the humidity in the space? What is the...

    What is the humidity in the space? What is the cold surface temperature? Indoor dewpoint must be above cold surface temperature or condensation will result. What is the source of humidity?
  47. It's interesting that you did that. Many of use...

    It's interesting that you did that. Many of use don't time, time delays that are working. Maybe there is a component failing on the control board but it is not something that at a technician level we...
  48. Thread: help?

    by ckartson
    Replies
    19
    Views
    1,318

    My point exactly, Thanks for saying it clearly.

    My point exactly, Thanks for saying it clearly.
  49. Thread: help?

    by ckartson
    Replies
    19
    Views
    1,318

    What parts are you missing? you should need...

    What parts are you missing? you should need control wire, power wire, acr pipe, armaflex insulation, special Y fittings.
  50. I looked up the wiring diagram for your furnace...

    I looked up the wiring diagram for your furnace and see the note 7 that you are referring to. The jumper will allow the fan to run at a higher speed when the stat is set to fan on. Depending on duct...